메뉴 건너뛰기




Volumn 112, Issue 1-2, 2003, Pages 111-115

Antithrombin activity of lepirudin adsorbed to silicone (polydimethylsiloxane) tubing

Author keywords

Lepirudin; Polydimethylsiloxane; Silicone; Venous catheters

Indexed keywords

ANTICOAGULANT AGENT; ARGATROBAN; DESULFATOHIRUDIN; DIMETICONE; LEPIRUDIN; POLYMER; THROMBIN;

EID: 0842303027     PISSN: 00493848     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.thromres.2003.10.009     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 0842320179 scopus 로고    scopus 로고
    • The use of venous access devices
    • E. Beutler, B.S. Coller, M.A. Lichtman, T.J. Kipps, & U. Seligsohn. New York: McGraw-Hill
    • Horne M.K., Mayo D.J., Freifeld A.G. The use of venous access devices. Beutler E., Coller B.S., Lichtman M.A., Kipps T.J., Seligsohn U. Williams hematology. 6th ed. 2001;257-259 McGraw-Hill, New York.
    • (2001) Williams Hematology 6th Ed. , pp. 257-259
    • Horne, M.K.1    Mayo, D.J.2    Freifeld, A.G.3
  • 4
    • 0026540882 scopus 로고
    • Adsorption of coagulation proteins from whole blood on to polymer materials: Relation to platelet activation
    • Elam J.H., Nygren H. Adsorption of coagulation proteins from whole blood on to polymer materials: relation to platelet activation. Biomaterials. 13:1992;3-8.
    • (1992) Biomaterials , vol.13 , pp. 3-8
    • Elam, J.H.1    Nygren, H.2
  • 5
    • 0036216941 scopus 로고    scopus 로고
    • Fibrinogen adsorption, platelet adhesion and thrombin generation at heparinized surfaces exposed to flowing blood
    • Keuren J.F.W., Wielders S.J.H., Willems G.M., Morra M., Lindhout T. Fibrinogen adsorption, platelet adhesion and thrombin generation at heparinized surfaces exposed to flowing blood. Thromb. Haemost. 87:2002;742-747.
    • (2002) Thromb. Haemost. , vol.87 , pp. 742-747
    • Keuren, J.F.W.1    Wielders, S.J.H.2    Willems, G.M.3    Morra, M.4    Lindhout, T.5
  • 7
    • 0036130454 scopus 로고    scopus 로고
    • Blood-compatible biomaterials by surface coating with a novel antithrombin-heparin covalent complex
    • Klement P., Du Y.J., Berry L., Andrew M., Chan A.K.C. Blood-compatible biomaterials by surface coating with a novel antithrombin-heparin covalent complex. Biomaterials. 23:2002;527-535.
    • (2002) Biomaterials , vol.23 , pp. 527-535
    • Klement, P.1    Du, Y.J.2    Berry, L.3    Andrew, M.4    Chan, A.K.C.5
  • 8
    • 0021040217 scopus 로고
    • A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue
    • Larm O., Larsson R., Olsson P. A new non-thrombogenic surface prepared by selective covalent binding of heparin via a modified reducing terminal residue. Biomater. Med. Dev. Artif. Organs. 11:1983;161-173.
    • (1983) Biomater. Med. Dev. Artif. Organs , vol.11 , pp. 161-173
    • Larm, O.1    Larsson, R.2    Olsson, P.3
  • 10
    • 0036800881 scopus 로고    scopus 로고
    • Pharmacology of recombinant hirudin
    • Nowak G. Pharmacology of recombinant hirudin. Semin. Thromb. Hemost. 28:2002;415-423.
    • (2002) Semin. Thromb. Hemost. , vol.28 , pp. 415-423
    • Nowak, G.1
  • 11
    • 0031282113 scopus 로고    scopus 로고
    • Covalent immobilization of hirudin improves the haemocompatibility of polylactide-polyglycolide in vitro
    • Seifert B., Romaniuk P., Groth T. Covalent immobilization of hirudin improves the haemocompatibility of polylactide-polyglycolide in vitro. Biomaterials. 18:1997;1495-1502.
    • (1997) Biomaterials , vol.18 , pp. 1495-1502
    • Seifert, B.1    Romaniuk, P.2    Groth, T.3
  • 13
    • 0022121881 scopus 로고
    • Immunochemical detection by specific antibody to thrombin of prothrombin conformational changes upon adsorption to artificial surfaces
    • Chuang H.Y.K., Andrade J.D. Immunochemical detection by specific antibody to thrombin of prothrombin conformational changes upon adsorption to artificial surfaces. J. Biomed. Mater. Res. 19:1985;813-825.
    • (1985) J. Biomed. Mater. Res. , vol.19 , pp. 813-825
    • Chuang, H.Y.K.1    Andrade, J.D.2
  • 14
    • 0022520240 scopus 로고
    • Does the conformation of adsorbed fibrinogen dictate platelet interactions with artificial surfaces?
    • Lindon J.N., McManama G., Kushner L., Merrill E.W., Salzman E.W. Does the conformation of adsorbed fibrinogen dictate platelet interactions with artificial surfaces? Blood. 68:1986;355-362.
    • (1986) Blood , vol.68 , pp. 355-362
    • Lindon, J.N.1    McManama, G.2    Kushner, L.3    Merrill, E.W.4    Salzman, E.W.5
  • 15
    • 0023889391 scopus 로고
    • Heparin-coated catheters and heparin-induced thrombocytopenia
    • Laster J., Silver D. Heparin-coated catheters and heparin-induced thrombocytopenia. J. Vasc. Surg. 7:1988;667-672.
    • (1988) J. Vasc. Surg. , vol.7 , pp. 667-672
    • Laster, J.1    Silver, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.