메뉴 건너뛰기




Volumn 1, Issue , 2003, Pages 422-427

Determination of Frequency Variation Effect on DFT-based Algorithms for Harmonic and Flicker Measurements

Author keywords

DFT Application; Flicker; Frequency variation; Harmonic; Power quality

Indexed keywords

ALGORITHMS; COMPUTER SIMULATION; DISCRETE FOURIER TRANSFORMS; ELECTRIC POTENTIAL; FREQUENCIES; HARMONIC ANALYSIS; MODULATION; WAVEFORM ANALYSIS;

EID: 0842288299     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (6)

References (14)
  • 5
    • 0026237899 scopus 로고
    • Digital Measurement of Voltage Flicker
    • Oct.
    • K. Srinivasan, "Digital Measurement of Voltage Flicker," IEEE Trans. On PWRD, 7(1), Oct. 1991, pp.1593-1598.
    • (1991) IEEE Trans. on PWRD , vol.7 , Issue.1 , pp. 1593-1598
    • Srinivasan, K.1
  • 6
    • 0031094311 scopus 로고    scopus 로고
    • Digital Algorithms for Measurement of Voltage Flicker
    • March
    • M.T. Chen, "Digital Algorithms for Measurement of Voltage Flicker," IEE Proc.-G.T.D., 144(2), March 1997, pp.175-180.
    • (1997) IEE Proc.-G.T.D. , vol.144 , Issue.2 , pp. 175-180
    • Chen, M.T.1
  • 7
    • 0000224241 scopus 로고
    • Supply to Arc Furnace: Measurement and Prediction of Supply Voltage Fluctuation
    • April
    • G.F.L. Dixon, P.G Kendall, "Supply to Arc Furnace: Measurement and Prediction of Supply Voltage Fluctuation," Proc. Of IEE, 119(4), April 1972, pp.456-465.
    • (1972) Proc. of IEE , vol.119 , Issue.4 , pp. 456-465
    • Dixon, G.F.L.1    Kendall, P.G.2
  • 8
    • 0018542793 scopus 로고
    • Suppression and Measurement of Arc Furnace Flicker with a Large Static Var Compensator
    • Nov./Dec.
    • I.H.M. Yano, M.T.S. Yuya, S. Sueda, "Suppression and Measurement of Arc Furnace Flicker with a Large Static Var Compensator," IEEE Trans. On PAS, 98(6), Nov./Dec. 1979, pp.2276-2283.
    • (1979) IEEE Trans. on PAS , vol.98 , Issue.6 , pp. 2276-2283
    • Yano, I.H.M.1    Yuya, M.T.S.2    Sueda, S.3
  • 9
    • 0032625257 scopus 로고    scopus 로고
    • A Direct Calculation Algorithm for Digital Measurement of Equivalent Voltage Flicker
    • Chicago, Illinois, April
    • M.T. Chen, C.W. Lu, "A Direct Calculation Algorithm for Digital Measurement of Equivalent Voltage Flicker," Proceeding of the American Power Conference, Chicago, Illinois, April 1999, pp.704-708.
    • (1999) Proceeding of the American Power Conference , pp. 704-708
    • Chen, M.T.1    Lu, C.W.2
  • 10
    • 0018907856 scopus 로고
    • A Quantitive Study of Pit Falls in the FFT
    • A.A. Girgis, F.M. Ham, "A Quantitive Study of Pit Falls in the FFT," IEEE Trans. on AES, 16(4), 1980, pp.434-439.
    • (1980) IEEE Trans. on AES , vol.16 , Issue.4 , pp. 434-439
    • Girgis, A.A.1    Ham, F.M.2
  • 12
    • 0036085347 scopus 로고    scopus 로고
    • A Hybrid Digital Algorithm for Harmonic and Flicker Measurement
    • NY, U.S.A., Jan., 0-7803-7322-71021
    • M.T. Chen, A.P. Meliopoulos, "A Hybrid Digital Algorithm for Harmonic and Flicker Measurement," Proceedings of 2002 IEEE PES Winter Meeting, NY, U.S.A., Jan. 2002, 0-7803-7322-71021.
    • (2002) Proceedings of 2002 IEEE PES Winter Meeting
    • Chen, M.T.1    Meliopoulos, A.P.2
  • 13
    • 0020267687 scopus 로고
    • Characteristics of the Eastern Interconnection Line Frequency
    • December
    • R.K. Adams, J.M. McIntyre, F.W. Symonds, "Characteristics of The Eastern Interconnection Line Frequency," IEEE Trans. On Power Apparatus and System, PAS-101(12), December 1982, pp. 4542-4547.
    • (1982) IEEE Trans. on Power Apparatus and System , vol.PAS-101 , Issue.12 , pp. 4542-4547
    • Adams, R.K.1    McIntyre, J.M.2    Symonds, F.W.3
  • 14
    • 0842329371 scopus 로고
    • Power Quality, Harmonic, and Disturbances
    • Aug.
    • S.S. Yen, Power Quality, Harmonic, and Disturbances, Lecture Material (in Chinese), Aug. 1992.
    • (1992) Lecture Material (in Chinese)
    • Yen, S.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.