메뉴 건너뛰기




Volumn 111, Issue 2, 2004, Pages 309-317

Initial results of endothelial cell counts after Artisan Lens for Phakic Eyes: An evaluation of the United States food and drug administration ophtec study

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; CELL COUNT; CELL DENSITY; CELL LOSS; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; ENDOTHELIUM CELL; FOLLOW UP; HUMAN; HUMAN CELL; HUMAN TISSUE; LENS; LENS IMPLANT; MAJOR CLINICAL STUDY; MEDICAL PRACTICE; MULTICENTER STUDY; MYOPIA; PRIORITY JOURNAL; RISK ASSESSMENT; SPECULAR MICROSCOPY; STATISTICAL SIGNIFICANCE; TREATMENT OUTCOME; UNITED STATES;

EID: 0842267248     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2003.05.025     Document Type: Article
Times cited : (124)

References (22)
  • 2
    • 0030784819 scopus 로고    scopus 로고
    • Iris claw phakic intraocular lens for high myopia
    • Menezo J.L., Avino J.A., Cisneros A., et al. Iris claw phakic intraocular lens for high myopia. J Refract Surg. 13:1997;545-555.
    • (1997) J Refract Surg , vol.13 , pp. 545-555
    • Menezo, J.L.1    Avino, J.A.2    Cisneros, A.3
  • 3
    • 0035197912 scopus 로고    scopus 로고
    • Iris-claw phakic intraocular lens for high myopia
    • Landesz M., van Rij G., Luyten G. Iris-claw phakic intraocular lens for high myopia. J Refract Surg. 17:2001;634-640.
    • (2001) J Refract Surg , vol.17 , pp. 634-640
    • Landesz, M.1    Van Rij, G.2    Luyten, G.3
  • 4
    • 0033805132 scopus 로고    scopus 로고
    • Multicenter study of the Artisan phakic intraocular lens
    • Budo C., Hessloehl J.C., Izak M., et al. Multicenter study of the Artisan phakic intraocular lens. J Cataract Refract Surg. 26:2000;1163-1171.
    • (2000) J Cataract Refract Surg , vol.26 , pp. 1163-1171
    • Budo, C.1    Hessloehl, J.C.2    Izak, M.3
  • 5
    • 0030944593 scopus 로고    scopus 로고
    • Central corneal endothelial cell changes over a ten-year period
    • Bourne W.M., Nelson L.R., Hodge D.O. Central corneal endothelial cell changes over a ten-year period. Invest Ophthal Vis Sci. 38:1997;779-782.
    • (1997) Invest Ophthal Vis Sci , vol.38 , pp. 779-782
    • Bourne, W.M.1    Nelson, L.R.2    Hodge, D.O.3
  • 6
    • 85030903962 scopus 로고    scopus 로고
    • October 22-23, 1998
    • U.S. Food and Drug Administration, Center for Devices and Radiological Health. Ophthalmic Devices Panel meeting summaries. October 22-23, 1998. Available at: http://www.fda.gov/cdrh/odp.html. Accessed October 23, 2003.
    • Ophthalmic Devices Panel Meeting Summaries
  • 7
    • 0034828598 scopus 로고    scopus 로고
    • Two-year corneal endothelial cell assessment following INTACS implantation
    • Azar R.G., Holdbrook M.R., Lemp M., et al. Two-year corneal endothelial cell assessment following INTACS implantation. J Refract Surg. 17:2001;542-548.
    • (2001) J Refract Surg , vol.17 , pp. 542-548
    • Azar, R.G.1    Holdbrook, M.R.2    Lemp, M.3
  • 8
    • 0027522540 scopus 로고
    • Long-term endothelial cell loss following phacoemulsification: Model for evaluating endothelial damage after intraocular surgery
    • Werblin T.P. Long-term endothelial cell loss following phacoemulsification model for evaluating endothelial damage after intraocular surgery . Refract Corneal Surg. 9:1993;29-35.
    • (1993) Refract Corneal Surg , vol.9 , pp. 29-35
    • Werblin, T.P.1
  • 9
    • 0026073067 scopus 로고
    • Corneal endothelial response to polymethylmethacrylate versus hydrogel lenses after phacoemulsification
    • Tingey D.P., Nichols B.D., Jung S.E., Randall P.E. Corneal endothelial response to polymethylmethacrylate versus hydrogel lenses after phacoemulsification. Can J Ophthalmol. 26:1991;3-6.
    • (1991) Can J Ophthalmol , vol.26 , pp. 3-6
    • Tingey, D.P.1    Nichols, B.D.2    Jung, S.E.3    Randall, P.E.4
  • 11
    • 0032052712 scopus 로고    scopus 로고
    • Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium
    • Jones S.S., Azar R.G., Cristol S.M., et al. Effects of laser in situ keratomileusis (LASIK) on the corneal endothelium. Am J Ophthalmol. 135:1998;465-471.
    • (1998) Am J Ophthalmol , vol.135 , pp. 465-471
    • Jones, S.S.1    Azar, R.G.2    Cristol, S.M.3
  • 12
    • 0029805513 scopus 로고    scopus 로고
    • The effect of photorefractive keratectomy on the corneal endothelium
    • Stulting R.D., Thompson K.P., Waring G.O. III, Lynn M. The effect of photorefractive keratectomy on the corneal endothelium. Ophthalmology. 103:1996;1357-1365.
    • (1996) Ophthalmology , vol.103 , pp. 1357-1365
    • Stulting, R.D.1    Thompson, K.P.2    Waring III, G.O.3    Lynn, M.4
  • 13
    • 0027963513 scopus 로고
    • Corneal endothelium five years after transplantation
    • Bourne W.M., Hodge D.O., Nelson L.R. Corneal endothelium five years after transplantation. Am J Ophthalmol. 118:1994;185-196.
    • (1994) Am J Ophthalmol , vol.118 , pp. 185-196
    • Bourne, W.M.1    Hodge, D.O.2    Nelson, L.R.3
  • 14
    • 0031907136 scopus 로고    scopus 로고
    • Endothelial cell density and contact lens-induced corneal swelling
    • Erickson P., Doughty M.J., Compstock T.L., Cullen A.P. Endothelial cell density and contact lens-induced corneal swelling. Cornea. 17:1998;152-157.
    • (1998) Cornea , vol.17 , pp. 152-157
    • Erickson, P.1    Doughty, M.J.2    Compstock, T.L.3    Cullen, A.P.4
  • 15
    • 0032978993 scopus 로고    scopus 로고
    • Estimation of corneal endothelial pump function in long-term contact lens wearers
    • Bourne W.M., Hodge D.O., McLaren J.W. Estimation of corneal endothelial pump function in long-term contact lens wearers. Invest Ophthalmol Vis Sci. 40:1999;603-611.
    • (1999) Invest Ophthalmol Vis Sci , vol.40 , pp. 603-611
    • Bourne, W.M.1    Hodge, D.O.2    McLaren, J.W.3
  • 16
    • 0342680092 scopus 로고    scopus 로고
    • Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope
    • Doughty M.J., Muller A., Zaman M.L. Assessment of the reliability of human corneal endothelial cell-density estimates using a noncontact specular microscope. Cornea. 19:2000;148-158.
    • (2000) Cornea , vol.19 , pp. 148-158
    • Doughty, M.J.1    Muller, A.2    Zaman, M.L.3
  • 17
    • 0029115286 scopus 로고
    • Comparative study of three semiautomated specular microscopes
    • Landesz M., Siertsema J.V., Van Rij G. Comparative study of three semiautomated specular microscopes. J Cataract Refract Surg. 21:1995;409-416.
    • (1995) J Cataract Refract Surg , vol.21 , pp. 409-416
    • Landesz, M.1    Siertsema, J.V.2    Van Rij, G.3
  • 18
    • 0036798205 scopus 로고    scopus 로고
    • Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy
    • Modis L. Jr, Langenbucher A., Seitz B. Corneal endothelial cell density and pachymetry measured by contact and noncontact specular microscopy. J Cataract Refract Surg. 28:2002;1763-1769.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1763-1769
    • Modis Jr., L.1    Langenbucher, A.2    Seitz, B.3
  • 19
    • 0028351355 scopus 로고
    • The long-term effects of polymethylmethacrylate contact lens wear on the corneal endothelium
    • MacRae S.M., Matsuda M., Phillips D.S. The long-term effects of polymethylmethacrylate contact lens wear on the corneal endothelium. Ophthalmology. 101:1994;365-370.
    • (1994) Ophthalmology , vol.101 , pp. 365-370
    • MacRae, S.M.1    Matsuda, M.2    Phillips, D.S.3
  • 20
    • 0033988697 scopus 로고    scopus 로고
    • The effect of contact lens wear on the central and peripheral corneal endothelium
    • Wiffen S.J., Hodge D.O., Bourne W.M. The effect of contact lens wear on the central and peripheral corneal endothelium. Cornea. 19:2000;47-51.
    • (2000) Cornea , vol.19 , pp. 47-51
    • Wiffen, S.J.1    Hodge, D.O.2    Bourne, W.M.3
  • 22
    • 0036855245 scopus 로고    scopus 로고
    • Risk factors for reduced corneal endothelial cell density before cataract surgery
    • Ishikawa A. Risk factors for reduced corneal endothelial cell density before cataract surgery. J Cataract Refract Surg. 28:2002;1982-1992.
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1982-1992
    • Ishikawa, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.