-
1
-
-
0019192603
-
Digital function following flexor tendon repair in Zone II: A comparison of immobilization and controlled passive motion techniques
-
Strickland JW, Glogovac SV. Digital function following flexor tendon repair in Zone II: a comparison of immobilization and controlled passive motion techniques. J Hand Surg 1980;5:537-543.
-
(1980)
J Hand Surg
, vol.5
, pp. 537-543
-
-
Strickland, J.W.1
Glogovac, S.V.2
-
2
-
-
0020074121
-
Effects of early intermittent passive mobilization on healing canine flexor tendons
-
Gelberman RH, Woo SLY, Lothringer K, Akeson WH, Amiel D. Effects of early intermittent passive mobilization on healing canine flexor tendons. J Hand Surg 1982;7:170-175.
-
(1982)
J Hand Surg
, vol.7
, pp. 170-175
-
-
Gelberman, R.H.1
Woo, S.L.Y.2
Lothringer, K.3
Akeson, W.H.4
Amiel, D.5
-
3
-
-
0034107209
-
Development of flexor tendon surgery: Twenty-five years of progress
-
Strickland JW. Development of flexor tendon surgery: twenty-five years of progress. J Hand Surg 2000;25A:214-235.
-
(2000)
J Hand Surg
, vol.25 A
, pp. 214-235
-
-
Strickland, J.W.1
-
4
-
-
0034193847
-
A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model
-
Barrie KA, Wolfe SW, Shean C, Shenbagamurthi D, Slade JF III, Panjabi MM. A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model. J Hand Surg 2000;25A:499-506.
-
(2000)
J Hand Surg
, vol.25 A
, pp. 499-506
-
-
Barrie, K.A.1
Wolfe, S.W.2
Shean, C.3
Shenbagamurthi, D.4
Slade III, J.F.5
Panjabi, M.M.6
-
5
-
-
0032451633
-
Two-, four-, and six-strand zone II flexor tendon repairsan in situ biomechanical comparison using a cadaver model
-
Thurman RT, Trumble TE, Hanel DP, Tencer AF, Kiser PK. Two-, four-, and six-strand zone II flexor tendon repairsan in situ biomechanical comparison using a cadaver model. J Hand Surg 1998;23A:261-265.
-
(1998)
J Hand Surg
, vol.23 A
, pp. 261-265
-
-
Thurman, R.T.1
Trumble, T.E.2
Hanel, D.P.3
Tencer, A.F.4
Kiser, P.K.5
-
6
-
-
0025787528
-
An experimental model for the study of canine flexor tendon adhesions
-
Rothkopf DM, Webb S, Szabo RM, Gelberman RH, May JW Jr. An experimental model for the study of canine flexor tendon adhesions. J Hand Surg 1991;16A:694-700.
-
(1991)
J Hand Surg
, vol.16 A
, pp. 694-700
-
-
Rothkopf, D.M.1
Webb, S.2
Szabo, R.M.3
Gelberman, R.H.4
May Jr., J.W.5
-
7
-
-
0029004316
-
Work of flexion after tendon repair with various suture methods. A human cadaveric study
-
Aoki M, Manske PR, Pruitt DL, Larson BJ. Work of flexion after tendon repair with various suture methods. A human cadaveric study. J Hand Surg 1995;20B:310-313.
-
(1995)
J Hand Surg
, vol.20 B
, pp. 310-313
-
-
Aoki, M.1
Manske, P.R.2
Pruitt, D.L.3
Larson, B.J.4
-
8
-
-
0027626207
-
In vitro biomechanical analysis of suture methods for flexor tendon repair
-
Noguchi M, Seiler JG III, Gelberman RH, Sofranko RA, Woo SL-Y. In vitro biomechanical analysis of suture methods for flexor tendon repair. J Orthop Res 1993;11:603-611.
-
(1993)
J Orthop Res
, vol.11
, pp. 603-611
-
-
Noguchi, M.1
Seiler III, J.G.2
Gelberman, R.H.3
Sofranko, R.A.4
Woo, S.L.-Y.5
-
9
-
-
0032955183
-
Decrease in adhesion formation by a single application of 5-Fluorouracil after flexor tendon injury
-
Akali A, Khan U, Khaw PT, McGrouther AD. Decrease in adhesion formation by a single application of 5-Fluorouracil after flexor tendon injury. Plast Reconstr Surg 1999;103:151-158.
-
(1999)
Plast Reconstr Surg
, vol.103
, pp. 151-158
-
-
Akali, A.1
Khan, U.2
Khaw, P.T.3
McGrouther, A.D.4
-
10
-
-
0034068726
-
Adhesions from flexor tendon surgery: An animal study comparing surgical techniques
-
Hatano I, Suga T, Diao E, Peimer CA, Howard C. Adhesions from flexor tendon surgery: an animal study comparing surgical techniques. J Hand Surg 2000;25A:252-259.
-
(2000)
J Hand Surg
, vol.25 A
, pp. 252-259
-
-
Hatano, I.1
Suga, T.2
Diao, E.3
Peimer, C.A.4
Howard, C.5
-
11
-
-
0016188971
-
Some practical notes on the anatomy of the chicken toe for surgeon investigators
-
Farkas LG, Thomson HG, Martin R. Some practical notes on the anatomy of the chicken toe for surgeon investigators. Plast Reconstr Surg 1974;54:452-458.
-
(1974)
Plast Reconstr Surg
, vol.54
, pp. 452-458
-
-
Farkas, L.G.1
Thomson, H.G.2
Martin, R.3
-
12
-
-
0018901190
-
Functional return of tendon graft protected entirely by pseudosheath-experimental study
-
Farkas LG, Lindsay WK. Functional return of tendon graft protected entirely by pseudosheath-experimental study. Plast Reconstr Surg 1980;65:188-194.
-
(1980)
Plast Reconstr Surg
, vol.65
, pp. 188-194
-
-
Farkas, L.G.1
Lindsay, W.K.2
-
13
-
-
0025276640
-
Early tensile properties of healing chicken flexor tendons: Early controlled passive motion versus postoperative immobilization
-
Feehan LM, Beauchene JG. Early tensile properties of healing chicken flexor tendons: early controlled passive motion versus postoperative immobilization. J Hand Surg 1990;15A:63-68.
-
(1990)
J Hand Surg
, vol.15 A
, pp. 63-68
-
-
Feehan, L.M.1
Beauchene, J.G.2
-
14
-
-
0023277784
-
The effect of immediate constrained digital motion on the strength of flexor tendon repairs in chickens
-
Hitchcock TF, Light TR, Bunch WH, Knight GW, Sartori MJ, Patwardhan AG, Hollyfield RL. The effect of immediate constrained digital motion on the strength of flexor tendon repairs in chickens. J Hand Surg 1987;12A:590-595.
-
(1987)
J Hand Surg
, vol.12 A
, pp. 590-595
-
-
Hitchcock, T.F.1
Light, T.R.2
Bunch, W.H.3
Knight, G.W.4
Sartori, M.J.5
Patwardhan, A.G.6
Hollyfield, R.L.7
-
15
-
-
0033166224
-
Prevention of restrictive adhesions in primary tendon repair by HA-membrane: Experimental research in chickens
-
Işik S, Öztürk S, Gürses S, Selmanpakoǧlu N, Günhan Ö. Prevention of restrictive adhesions in primary tendon repair by HA-membrane: experimental research in chickens. Br J Plast Surg 1999;52:373-379.
-
(1999)
Br J Plast Surg
, vol.52
, pp. 373-379
-
-
Işik, S.1
Öztürk, S.2
Gürses, S.3
Selmanpakoǧlu, N.4
Günhan, Ö.5
-
16
-
-
0036064778
-
Characterization of the tensile properties and histologic/biochemical changes in normal chicken tendon at the site of suture insertion
-
McDowell CL, Marqueen TJ, Yager D, Owen JR, Wayne JS. Characterization of the tensile properties and histologic/biochemical changes in normal chicken tendon at the site of suture insertion. J Hand Surg 2002;27A:605-614.
-
(2002)
J Hand Surg
, vol.27 A
, pp. 605-614
-
-
McDowell, C.L.1
Marqueen, T.J.2
Yager, D.3
Owen, J.R.4
Wayne, J.S.5
-
17
-
-
0018583189
-
The influence of tendon sheath integrity and vincular blood supply on adhesion formation following tendon repair in hens
-
Pennington DG. The influence of tendon sheath integrity and vincular blood supply on adhesion formation following tendon repair in hens. Br J Plast Surg 1979;32:302-306.
-
(1979)
Br J Plast Surg
, vol.32
, pp. 302-306
-
-
Pennington, D.G.1
-
18
-
-
0025347477
-
Effect of various methods of restoring flexor sheath integrity on the formation of adhesions after tendon injury
-
Peterson WW, Manske PR, Dunlap J, Horwitz DS, Kahn B. Effect of various methods of restoring flexor sheath integrity on the formation of adhesions after tendon injury. J Hand Surg 1990;15A:48-56.
-
(1990)
J Hand Surg
, vol.15 A
, pp. 48-56
-
-
Peterson, W.W.1
Manske, P.R.2
Dunlap, J.3
Horwitz, D.S.4
Kahn, B.5
-
19
-
-
0022906186
-
Effect of flexor sheath integrity on tendon gliding: A biomechanical and histologic study
-
Peterson WW, Manske PR, Kain CC, Lesker PA. Effect of flexor sheath integrity on tendon gliding: a biomechanical and histologic study. J Orthop Res 1986;4:458-465.
-
(1986)
J Orthop Res
, vol.4
, pp. 458-465
-
-
Peterson, W.W.1
Manske, P.R.2
Kain, C.C.3
Lesker, P.A.4
-
20
-
-
0033045126
-
The effect of pulsed electromagnetic fields on flexor tendon healing in chickens
-
Robotti E, Zimbler AG, Kenna D, Grossman JAI. The effect of pulsed electromagnetic fields on flexor tendon healing in chickens. J Hand Surg 1999;24B:56-58.
-
(1999)
J Hand Surg
, vol.24 B
, pp. 56-58
-
-
Robotti, E.1
Zimbler, A.G.2
Kenna, D.3
Grossman, J.A.I.4
-
21
-
-
0029910439
-
Biomechanical and histologic evaluation of tendon sheath management
-
Tang JB, Shi D, Zhang QG. Biomechanical and histologic evaluation of tendon sheath management. J Hand Surg 1996;21A:900-908.
-
(1996)
J Hand Surg
, vol.21 A
, pp. 900-908
-
-
Tang, J.B.1
Shi, D.2
Zhang, Q.G.3
-
22
-
-
0035675445
-
Suture techniques with high breaking strength and low gliding resistance: Experiments in the dog flexor digitorum profundus tendon
-
Momose T, Amadio PC, Zhao C, Zobitz ME, Couvreur PJ, An K-N. Suture techniques with high breaking strength and low gliding resistance: experiments in the dog flexor digitorum profundus tendon. Acta Orthop Scand 2001;72:635-641.
-
(2001)
Acta Orthop Scand
, vol.72
, pp. 635-641
-
-
Momose, T.1
Amadio, P.C.2
Zhao, C.3
Zobitz, M.E.4
Couvreur, P.J.5
An, K.-N.6
-
23
-
-
0035210015
-
The effect of suture technique on adhesion formation after flexor tendon repair for partial lacerations in a canine model
-
Zhao C, Amadio PC, Momose T, Couvreur P, Zobitz ME, An K-N. The effect of suture technique on adhesion formation after flexor tendon repair for partial lacerations in a canine model. J Trauma 2001;51:917-921.
-
(2001)
J Trauma
, vol.51
, pp. 917-921
-
-
Zhao, C.1
Amadio, P.C.2
Momose, T.3
Couvreur, P.4
Zobitz, M.E.5
An, K.-N.6
-
25
-
-
0024369924
-
Flexor tendon repair: Significant gain in strength from the Halsted peripheral suture technique
-
Wade PJF, Wetherell RG, Amis AA. Flexor tendon repair: significant gain in strength from the Halsted peripheral suture technique. J Hand Surg 1989;14B:232-235.
-
(1989)
J Hand Surg
, vol.14 B
, pp. 232-235
-
-
Wade, P.J.F.1
Wetherell, R.G.2
Amis, A.A.3
-
26
-
-
0034836289
-
The effect of flexor tendon repair bulk on tendon gliding during simulated active motionan in vitro comparison of two-strand and six-strand techniques
-
Sanders DW, Milne AD, Johnson JA, Dunning CE, Richards RS, King GJW. The effect of flexor tendon repair bulk on tendon gliding during simulated active motionan in vitro comparison of two-strand and six-strand techniques. J Hand Surg 2001;26A:833-840.
-
(2001)
J Hand Surg
, vol.26 A
, pp. 833-840
-
-
Sanders, D.W.1
Milne, A.D.2
Johnson, J.A.3
Dunning, C.E.4
Richards, R.S.5
King, G.J.W.6
-
27
-
-
0028867547
-
Flexor tendon-pulley interaction after tendon repair. A biomechanical study
-
Coert JH, Uchiyama S, Amadio PC, Berglund LJ, An KN. Flexor tendon-pulley interaction after tendon repair. A biomechanical study. J Hand Surg 1995;20B:573-577.
-
(1995)
J Hand Surg
, vol.20 B
, pp. 573-577
-
-
Coert, J.H.1
Uchiyama, S.2
Amadio, P.C.3
Berglund, L.J.4
An, K.N.5
|