메뉴 건너뛰기




Volumn 125, Issue 6, 2003, Pages 881-886

Improving Elbow Torque Output of Stroke Patients with Assistive Torque Controlled by EMG Signals

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; BIOMECHANICS; CARDIOVASCULAR SYSTEM; ELECTROMYOGRAPHY; PATIENT TREATMENT; PHYSIOLOGY; TORQUE;

EID: 0742288959     PISSN: 01480731     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.1634284     Document Type: Article
Times cited : (48)

References (14)
  • 1
    • 0032103958 scopus 로고    scopus 로고
    • A Comparison between Control Methods for Implanted FES Hand-Grasp Systems
    • Hart, R. L., Kilgore, K. L., and Peckham, P., 1998, "A Comparison Between Control Methods for Implanted FES Hand-Grasp Systems," IEEE Trans. Rehabil. Eng., 6(2), pp. 208-218.
    • (1998) IEEE Trans. Rehabil. Eng. , vol.6 , Issue.2 , pp. 208-218
    • Hart, R.L.1    Kilgore, K.L.2    Peckham, P.3
  • 2
    • 0028944763 scopus 로고
    • An EMG-Controlled Grasping System for Tetraplegics
    • Saxena, S., Nikolic, S., and Popovic, D., 1995, "An EMG-Controlled Grasping System for Tetraplegics," J. Rehabil. Res. Dev., 32(1), pp. 17-24.
    • (1995) J. Rehabil. Res. Dev. , vol.32 , Issue.1 , pp. 17-24
    • Saxena, S.1    Nikolic, S.2    Popovic, D.3
  • 3
    • 0031170811 scopus 로고    scopus 로고
    • Functional Neuromuscular Stimulation Controlled by Surface Electromyographic Signals Produced by Volitional Activation of the Same Muscle: Adaptive Removal of the Muscle Response from the Recorded EMG-Signal
    • Sennels, S., Bjering-sørensen, F., Andersen, O. T., and Hansen, S. D., 1997, "Functional Neuromuscular Stimulation Controlled by Surface Electromyographic Signals Produced by Volitional Activation of the Same Muscle: Adaptive Removal of the Muscle Response from the Recorded EMG-Signal," IEEE Trans. Rehabil. Eng., 5(2), pp. 195-206.
    • (1997) IEEE Trans. Rehabil. Eng. , vol.5 , Issue.2 , pp. 195-206
    • Sennels, S.1    Bjering-Sørensen, F.2    Andersen, O.T.3    Hansen, S.D.4
  • 4
    • 0033106215 scopus 로고    scopus 로고
    • Guidance-Based Quantification of Arm Impairment Following Brain Injury
    • Reinkensmeyer, D. J., Dewald, J. P. A., and Rymer, W. Z., 1999, "Guidance-Based Quantification of Arm Impairment Following Brain Injury," IEEE Trans. Rehabil. Eng., 7(1), pp. 1-11.
    • (1999) IEEE Trans. Rehabil. Eng. , vol.7 , Issue.1 , pp. 1-11
    • Reinkensmeyer, D.J.1    Dewald, J.P.A.2    Rymer, W.Z.3
  • 5
    • 0033335153 scopus 로고    scopus 로고
    • Evaluation of an Assistive Controller for Reaching Following Brain Injury
    • Reinkensmeyer, D., Takahashi C., and Timoszyk, W., 1999, "Evaluation of an Assistive Controller for Reaching Following Brain Injury," BMES/EMBS Conference, pp. 631.
    • (1999) BMES/EMBS Conference , pp. 631
    • Reinkensmeyer, D.1    Takahashi, C.2    Timoszyk, W.3
  • 6
    • 0033052172 scopus 로고    scopus 로고
    • Robotic Assistance of an Active Upper Limb Exercise in Neurologically Impaired Patients
    • Cozens, J. A., 1999, "Robotic Assistance of an Active Upper Limb Exercise in Neurologically Impaired Patients," IEEE Trans. Rehabil. Eng., 7(2), pp. 254-256.
    • (1999) IEEE Trans. Rehabil. Eng. , vol.7 , Issue.2 , pp. 254-256
    • Cozens, J.A.1
  • 7
    • 0035359272 scopus 로고    scopus 로고
    • An Exoskeletal Robot for Human Elbow Motion Support-Sensor Fusion, Adaptation, and Control
    • Kiguchi, K., Kariya, S., watanable, K., Izumi, K., and Fukuda, T., 2001, "An Exoskeletal Robot for Human Elbow Motion Support-Sensor Fusion, Adaptation, and Control," IEEE Trans. Syst. Man Cybern., 31(3), pp. 353-361.
    • (2001) IEEE Trans. Syst. Man Cybern. , vol.31 , Issue.3 , pp. 353-361
    • Kiguchi, K.1    Kariya, S.2    Watanable, K.3    Izumi, K.4    Fukuda, T.5
  • 9
    • 0019226631 scopus 로고
    • Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography-Part I: Derivation of the Optimal Myprocessor
    • Hogan, N., and Mann, R. W., 1980, "Myoelectric Signal Processing: Optimal Estimation Applied to Electromyography-Part I: Derivation of the Optimal Myprocessor," IEEE Trans. Biomed. Eng., 27(7), pp. 382-395.
    • (1980) IEEE Trans. Biomed. Eng. , vol.27 , Issue.7 , pp. 382-395
    • Hogan, N.1    Mann, R.W.2
  • 10
    • 0024000563 scopus 로고
    • The Electromyogram (EMG) as a Control Signal for Functional Neuromuscular Stimulation-Part I: Autoregressive Modeling as a Means of EMG Signature Discrimination
    • Hefftner, G., Zucchini, W., and Jaros, G. G., 1988, "The Electromyogram (EMG) as a Control Signal for Functional Neuromuscular Stimulation-Part I: Autoregressive Modeling as a Means of EMG Signature Discrimination," IEEE Trans. Biomed. Eng., 35(4), pp. 230-237.
    • (1988) IEEE Trans. Biomed. Eng. , vol.35 , Issue.4 , pp. 230-237
    • Hefftner, G.1    Zucchini, W.2    Jaros, G.G.3
  • 11
    • 0029542621 scopus 로고
    • EMG Feature Evaluation for Movement Control of Upper Extremity Prostheses
    • Zardoshti-Kermani, M., Wheeler, B. C., and Hashemi, R. M., 1995, "EMG Feature Evaluation for Movement Control of Upper Extremity Prostheses," IEEE Trans. Rehabil. Eng., 3(4), pp. 324-333.
    • (1995) IEEE Trans. Rehabil. Eng. , vol.3 , Issue.4 , pp. 324-333
    • Zardoshti-Kermani, M.1    Wheeler, B.C.2    Hashemi, R.M.3
  • 13
    • 0003110481 scopus 로고
    • "Nonlinear Damping of Limb Motion," Chapter 13
    • edited by J. M. Winters and S. L.-Y. Woo, published by Springer-Verlag
    • Wu, C.-H., Houk, J. C., Young, K.-Y., and Miller, L. E., 1990, "Nonlinear Damping of Limb Motion," Chapter 13, in Multiple muscle systems, edited by J. M. Winters and S. L.-Y. Woo, published by Springer-Verlag.
    • (1990) Multiple Muscle Systems
    • Wu, C.-H.1    Houk, J.C.2    Young, K.-Y.3    Miller, L.E.4
  • 14
    • 0029380440 scopus 로고
    • Adaptive Filtering of the Electromyographic Signal for Prosthetic Control and Force Estimation
    • Park, E., and Meek, S. G., 1995, "Adaptive Filtering of the Electromyographic Signal for Prosthetic Control and Force Estimation," IEEE Trans. Biomed. Eng., 42(10), pp. 1048-1052.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.10 , pp. 1048-1052
    • Park, E.1    Meek, S.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.