메뉴 건너뛰기




Volumn 29, Issue 3, 2004, Pages 293-297

Noninvasive Magnetic Resonance to Three-Dimensional Rotational X-Ray Registration of Vertebral Bodies for Image-Guided Spine Surgery

Author keywords

3DRX; Image guided surgery; MRI; Mutual information; Percutaneous spine surgery; Registration; Vertebra

Indexed keywords

ARTICLE; CADAVER; CLINICAL ARTICLE; HUMAN; IMAGE GUIDED SURGERY; IMAGE RECONSTRUCTION; IMAGING SYSTEM; LUMBAR SPINE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SPINE SURGERY; THORACIC SPINE; THREE DIMENSIONAL IMAGING; VERTEBRA BODY;

EID: 0742287325     PISSN: 03622436     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.BRS.0000106980.33936.AD     Document Type: Article
Times cited : (19)

References (30)
  • 1
    • 0036276623 scopus 로고    scopus 로고
    • Spinal navigation in tumor surgery of the thoracic spine: First clinical results
    • Arand M, Hartwig E, Kinzl L, et al. Spinal navigation in tumor surgery of the thoracic spine: first clinical results. Clin Ortbop. 2002;399:211-218.
    • (2002) Clin Ortbop , vol.399 , pp. 211-218
    • Arand, M.1    Hartwig, E.2    Kinzl, L.3
  • 2
    • 0035420923 scopus 로고    scopus 로고
    • Image-guided endoscopic spine surgery: I. A feasibility study
    • Assaker R, Cinquin P, Cotton A, et al. Image-guided endoscopic spine surgery: I. A feasibility study. Spine. 2001;26:1705-1710.
    • (2001) Spine , vol.26 , pp. 1705-1710
    • Assaker, R.1    Cinquin, P.2    Cotton, A.3
  • 3
    • 0035420743 scopus 로고    scopus 로고
    • Image-guided endoscopic spine surgery. II: Clinical applications
    • Assaker R, Reyns N, Pertruzon B, et al. Image-guided endoscopic spine surgery. II: Clinical applications. Spine. 2001;26:1711-1718.
    • (2001) Spine , vol.26 , pp. 1711-1718
    • Assaker, R.1    Reyns, N.2    Pertruzon, B.3
  • 4
    • 0035865441 scopus 로고    scopus 로고
    • Computer-assisted thoracic pedicle screw placement: An in vitro feasibility study
    • Kim KD, Johnson JP, Bloch O, et al. Computer-assisted thoracic pedicle screw placement: an in vitro feasibility study. Spine. 2001;26:360-364.
    • (2001) Spine , vol.26 , pp. 360-364
    • Kim, K.D.1    Johnson, J.P.2    Bloch, O.3
  • 6
    • 0001908749 scopus 로고    scopus 로고
    • Computer-assisted surgery in posterior instrumentation of the cervical spine: And in-vitro feasibility study
    • Richter M, Amiot LP, Neller S, et al. Computer-assisted surgery in posterior instrumentation of the cervical spine: and in-vitro feasibility study. Eur Spine J. 2000;9(suppl):65-70.
    • (2000) Eur Spine J , vol.9 , Issue.SUPPL. , pp. 65-70
    • Richter, M.1    Amiot, L.P.2    Neller, S.3
  • 7
    • 0002660907 scopus 로고    scopus 로고
    • Computer-assisted spine surgery
    • Schlenzka D, Laine T, Lund T. Computer-assisted spine surgery. Eur Spine J. 2002;9(suppl):57-64.
    • (2002) Eur Spine J , vol.9 , Issue.SUPPL. , pp. 57-64
    • Schlenzka, D.1    Laine, T.2    Lund, T.3
  • 8
    • 0035865652 scopus 로고    scopus 로고
    • Virtual fluoroscopy: Computer-assisted fluoroscopic navigation
    • Foley KT, Simon DA, Rampersaud YR. Virtual fluoroscopy: computer-assisted fluoroscopic navigation Spine. 2001;46:347-351.
    • (2001) Spine , vol.46 , pp. 347-351
    • Foley, K.T.1    Simon, D.A.2    Rampersaud, Y.R.3
  • 9
    • 0036528299 scopus 로고    scopus 로고
    • Accuracy of fluoroscopic navigation of pedicle screws: CT-based evaluation of bone screw placement
    • Fritsch E, Duchow J, Seil R, et al. Accuracy of fluoroscopic navigation of pedicle screws: CT-based evaluation of bone screw placement. Orthopade. 2002;31:385-391.
    • (2002) Orthopade , vol.31 , pp. 385-391
    • Fritsch, E.1    Duchow, J.2    Seil, R.3
  • 10
    • 0002880775 scopus 로고    scopus 로고
    • A new approach to computer-aided spine surgery: Fluoroscopy-based surgical navigation
    • Nolte L-P, Slomezykowski MA, Berlemann U, et al. A new approach to computer-aided spine surgery: fluoroscopy-based surgical navigation. Eur Spine J. 2000;9(suppl):78-88.
    • (2000) Eur Spine J , vol.9 , Issue.SUPPL. , pp. 78-88
    • Nolte, L.-P.1    Slomezykowski, M.A.2    Berlemann, U.3
  • 12
    • 0032173357 scopus 로고    scopus 로고
    • Anatomy-based registration of CT-scan and intraoperative x-ray images for guiding a surgical robot
    • Guéziec A, Kazanzides P, Williamson B, et al. Anatomy-based registration of CT-scan and intraoperative x-ray images for guiding a surgical robot. IEEE Trans Med Imaging. 1998;17:715-728.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 715-728
    • Guéziec, A.1    Kazanzides, P.2    Williamson, B.3
  • 13
    • 0031904710 scopus 로고    scopus 로고
    • Automated 3-dimensional computed tomographic and fluoroscopic image registration
    • Hamadeh A, Lavallee S, Cinquin P. Automated 3-dimensional computed tomographic and fluoroscopic image registration. Comput Aided Surg. 1998;3:11-19.
    • (1998) Comput Aided Surg , vol.3 , pp. 11-19
    • Hamadeh, A.1    Lavallee, S.2    Cinquin, P.3
  • 17
    • 0032129157 scopus 로고    scopus 로고
    • A comparison of similarity measures for use in 2-D-3-D medical image registration
    • Penney GP, Weese J, Little JA, et al. A comparison of similarity measures for use in 2-D-3-D medical image registration. IEEE Trans Med Imaging. 1998;17:586-595.
    • (1998) IEEE Trans Med Imaging , vol.17 , pp. 586-595
    • Penney, G.P.1    Weese, J.2    Little, J.A.3
  • 18
    • 0032594330 scopus 로고    scopus 로고
    • Fast voxel-based 2D/3D registration algorithm using a volume rendering method based on the shear-warp factorization
    • Weese J, Göcke R, Penney GP, et al. Fast voxel-based 2D/3D registration algorithm using a volume rendering method based on the shear-warp factorization. Medical Imaging 1999: Image Processing, Proceedings of SPIE 1999;3661:802-810.
    • (1999) Medical Imaging 1999: Image Processing, Proceedings of SPIE , vol.3661 , pp. 802-810
    • Weese, J.1    Göcke, R.2    Penney, G.P.3
  • 22
    • 0031221119 scopus 로고    scopus 로고
    • Alignment by maximization of mutual information
    • Viola P, Wells WM III. Alignment by maximization of mutual information. Int J Comput Vision. 1997;24:137-154.
    • (1997) Int J Comput Vision , vol.24 , pp. 137-154
    • Viola, P.1    Wells III, W.M.2
  • 26
    • 0031106962 scopus 로고    scopus 로고
    • Multimodality image registration by maximization of mutual information
    • Maes F, Collignon A, Vandermeulen D, et al. Multimodality image registration by maximization of mutual information. IEEE Trans Med Imaging. 1997;16:187-198.
    • (1997) IEEE Trans Med Imaging , vol.16 , pp. 187-198
    • Maes, F.1    Collignon, A.2    Vandermeulen, D.3
  • 28
    • 84956669960 scopus 로고    scopus 로고
    • Matching 3D MR angiography data and 2D x-ray angiograms
    • Feldmar J, Malandain G, Ayache N, et al. Matching 3D MR angiography data and 2D x-ray angiograms. CVRMed-MRCAS. 1997;1205:129-138.
    • (1997) CVRMed-MRCAS , vol.1205 , pp. 129-138
    • Feldmar, J.1    Malandain, G.2    Ayache, N.3
  • 29
    • 84944056680 scopus 로고    scopus 로고
    • Multi-modal image registration by minimising Kullback-Leibler distance
    • LNCS 2498
    • Chung ACS, Wells WM III, Norbash A, et al. Multi-modal image registration by minimising Kullback-Leibler distance. MICCAI. 2002;(LNCS 2498): 525-532.
    • (2002) MICCAI , pp. 525-532
    • Chung, A.C.S.1    Wells III, W.M.2    Norbash, A.3
  • 30
    • 84944043372 scopus 로고    scopus 로고
    • A novel image similarity measure for registration of 3-D MR images and x-ray projection images
    • LNCS 2489
    • Rohlfing T, Maurer CR. A novel image similarity measure for registration of 3-D MR images and x-ray projection images. MICCAI. 2002; (LNCS 2489): 469-476.
    • (2002) MICCAI , pp. 469-476
    • Rohlfing, T.1    Maurer, C.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.