메뉴 건너뛰기




Volumn 42, Issue 1, 2004, Pages 1-17

Detection of glass contamination in horticultural peat with dual-energy X-ray absorptiometry (DXA)

Author keywords

Dual energy X ray absorptiometry; DXA; Glass detection; Horticultural peat; Non destructive quality assurance

Indexed keywords

AGRICULTURE; COMPOSITION; COMPUTER SOFTWARE; CONTAMINATION; ENERGY RESOURCES; GLASS; NONDESTRUCTIVE EXAMINATION; SIGNAL TO NOISE RATIO; X RAY ANALYSIS;

EID: 0742271226     PISSN: 01681699     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0168-1699(03)00083-8     Document Type: Article
Times cited : (12)

References (33)
  • 1
    • 0034908469 scopus 로고    scopus 로고
    • Measurement of mass attenuation coefficients for four mixtures using X-rays from 13 kVp up to 40 kVp
    • Angelone M., Esposito A., Chiti M., Gentile A. Measurement of mass attenuation coefficients for four mixtures using X-rays from 13 kVp up to 40 kVp. Radiat. Phys. Chem. 61:2001;547-548.
    • (2001) Radiat. Phys. Chem. , vol.61 , pp. 547-548
    • Angelone, M.1    Esposito, A.2    Chiti, M.3    Gentile, A.4
  • 3
    • 85030906962 scopus 로고
    • Hamburg, Germany: Philips Industrial X-ray GmbH
    • Anonymous. Specification for MCN 166 tube. 1981;Philips Industrial X-ray GmbH, Hamburg, Germany.
    • (1981) Specification for MCN 166 Tube
    • Anonymous1
  • 4
    • 0742280038 scopus 로고    scopus 로고
    • Feasibility of the X-ray technique for the detection of glass contamination in peat
    • Ayalew G., Holden N.M., Ward S.M. Feasibility of the X-ray technique for the detection of glass contamination in peat. Agrifood Eng. Res. Rev. 5:2000;69-72.
    • (2000) Agrifood Eng. Res. Rev. , vol.5 , pp. 69-72
    • Ayalew, G.1    Holden, N.M.2    Ward, S.M.3
  • 5
    • 0033390149 scopus 로고    scopus 로고
    • X-ray CT imaging and quality detection of peach at different physiological maturity
    • Barcelon E.G., Tojo S., Wantanabe K. X-ray CT imaging and quality detection of peach at different physiological maturity. Trans. ASAE. 42:(2):1999;435-441.
    • (1999) Trans. ASAE , vol.42 , Issue.2 , pp. 435-441
    • Barcelon, E.G.1    Tojo, S.2    Wantanabe, K.3
  • 7
    • 0742332647 scopus 로고    scopus 로고
    • Analysis of peat chemical composition for developing value-added classification of peat for industrial production
    • Beining B.A., Holden N.M., Ward S.M., Farrell E.P. Analysis of peat chemical composition for developing value-added classification of peat for industrial production. Int. Peat J. 10:2000;13-20.
    • (2000) Int. Peat J. , vol.10 , pp. 13-20
    • Beining, B.A.1    Holden, N.M.2    Ward, S.M.3    Farrell, E.P.4
  • 8
    • 0030657556 scopus 로고    scopus 로고
    • An accurate method for computer-generating tungsten anode X-ray spectra from 30 to 140 kV
    • Boone J.M., Seibert J.A. An accurate method for computer-generating tungsten anode X-ray spectra from 30 to 140 kV. Med. Phys. 24:(11):1997;1661- 1670.
    • (1997) Med. Phys. , vol.24 , Issue.11 , pp. 1661-1670
    • Boone, J.M.1    Seibert, J.A.2
  • 10
    • 0003409574 scopus 로고    scopus 로고
    • Upper Saddle River, NJ: Prentice-Hall. 07458
    • Castleman K. Digital Image Processing. 1996;71-99 Prentice-Hall, Upper Saddle River, NJ. 07458.
    • (1996) Digital Image Processing , pp. 71-99
    • Castleman, K.1
  • 11
    • 0021354483 scopus 로고
    • Studies of X-ray energy absorption and quantum noise properties of X-ray screens by use of Monte Carlo simulation
    • Chan H.-P., Doi K. Studies of X-ray energy absorption and quantum noise properties of X-ray screens by use of Monte Carlo simulation. Med. Phys. 11:(1):1984;37-46.
    • (1984) Med. Phys. , vol.11 , Issue.1 , pp. 37-46
    • Chan, H.-P.1    Doi, K.2
  • 17
    • 0021828887 scopus 로고
    • Theoretical optimization of dual-energy X-ray imaging with applications to mammography
    • Johns P.C., Yaffe M.J. Theoretical optimization of dual-energy X-ray imaging with applications to mammography. Med. Phys. 12:(3):1985;289-296.
    • (1985) Med. Phys. , vol.12 , Issue.3 , pp. 289-296
    • Johns, P.C.1    Yaffe, M.J.2
  • 19
    • 0016819212 scopus 로고
    • Photon attenuation in computed tomography
    • McCullough E.C. Photon attenuation in computed tomography. Med. Phys. 2:(6):1975;307-320.
    • (1975) Med. Phys. , vol.2 , Issue.6 , pp. 307-320
    • McCullough, E.C.1
  • 20
    • 0001384029 scopus 로고
    • Body composition by dual-energy X-ray absorptiometry - A review of the technology
    • Nord R.H., Payne R.K. Body composition by dual-energy X-ray absorptiometry - a review of the technology. Asia Pac. J. Clin. Nutr. 4:1995;167-171.
    • (1995) Asia Pac. J. Clin. Nutr. , vol.4 , pp. 167-171
    • Nord, R.H.1    Payne, R.K.2
  • 25
    • 0037210269 scopus 로고    scopus 로고
    • Explosive detection systems (EDS) for aviation security
    • Singh S., Singh M. Explosive detection systems (EDS) for aviation security. Signal Process. 83:2003;31-55.
    • (2003) Signal Process. , vol.83 , pp. 31-55
    • Singh, S.1    Singh, M.2
  • 26
    • 0034036231 scopus 로고    scopus 로고
    • Depth-segmented detector for X-ray absorptiometry
    • Stevens G.M., Pelc N.J. Depth-segmented detector for X-ray absorptiometry. Med. Phys. 27:(5):2000;1174-1184.
    • (2000) Med. Phys. , vol.27 , Issue.5 , pp. 1174-1184
    • Stevens, G.M.1    Pelc, N.J.2
  • 27
    • 0001046533 scopus 로고
    • Calculated bremmstrahlung spectra from thick tungsten targets
    • Storm E. Calculated bremmstrahlung spectra from thick tungsten targets. Phys. Rev. A5:(6):1972;2328-2338.
    • (1972) Phys. Rev. , vol.5 , Issue.6 , pp. 2328-2338
    • Storm, E.1
  • 28
    • 0029700775 scopus 로고    scopus 로고
    • Statistical evaluation of thermographic non-destructive testing performance applied to CFRP
    • Vavilov V.P., Bisson P.G., Grinzato E. Statistical evaluation of thermographic non-destructive testing performance applied to CFRP. Proc. SPIE. 2766:1996;174-177.
    • (1996) Proc. SPIE , vol.2766 , pp. 174-177
    • Vavilov, V.P.1    Bisson, P.G.2    Grinzato, E.3
  • 31
    • 0021475441 scopus 로고
    • Problems in the γ-transmission measurement of conveyed loads
    • Wykes J.S., Croke G.M. Problems in the γ-transmission measurement of conveyed loads. Int. J. Appl. Radiat. Isot. 35:(8):1984;731-741.
    • (1984) Int. J. Appl. Radiat. Isot. , vol.35 , Issue.8 , pp. 731-741
    • Wykes, J.S.1    Croke, G.M.2
  • 32
    • 0023206809 scopus 로고
    • Online measurement of the stone content of stone/coal loads using an X-ray tube source
    • Wykes J.S., Hoddy J.D., Croke G.M., Sandbank A. Online measurement of the stone content of stone/coal loads using an X-ray tube source. Nucl. Geophys. 1:(1):1987;59-69.
    • (1987) Nucl. Geophys. , vol.1 , Issue.1 , pp. 59-69
    • Wykes, J.S.1    Hoddy, J.D.2    Croke, G.M.3    Sandbank, A.4
  • 33
    • 0042814983 scopus 로고    scopus 로고
    • X-ray simulations for imaging applications in the agricultural and food industries
    • Zwiggelaar R., Bull C.R., Mooney M.J. X-ray simulations for imaging applications in the agricultural and food industries. J. Agric. Eng. Res. 63:1996;161-170.
    • (1996) J. Agric. Eng. Res. , vol.63 , pp. 161-170
    • Zwiggelaar, R.1    Bull, C.R.2    Mooney, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.