메뉴 건너뛰기




Volumn 5, Issue 5, 2003, Pages 364-368

Catheter ablation of ventricular tachycardia in patients with ischemic heart disease

Author keywords

[No Author keywords available]

Indexed keywords

AMIODARONE; BETA ADRENERGIC RECEPTOR BLOCKING AGENT;

EID: 0642346179     PISSN: 15233782     EISSN: None     Source Type: Journal    
DOI: 10.1007/s11886-003-0092-2     Document Type: Review
Times cited : (10)

References (26)
  • 1
    • 0037160734 scopus 로고    scopus 로고
    • Role of Purkinje conducting system in triggering of idiopathic ventricular fibrillation
    • Haissaguerre M, Shah DC, Jais P, et al.: Role of Purkinje conducting system in triggering of idiopathic ventricular fibrillation. Lancet 2002, 359:677-678.
    • (2002) Lancet , vol.359 , pp. 677-678
    • Haissaguerre, M.1    Shah, D.C.2    Jais, P.3
  • 2
    • 0027443890 scopus 로고
    • Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction
    • Stevenson WG, Khan H, Sager P, et al.: Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction. Circulation 1993, 88:1647-1670.
    • (1993) Circulation , vol.88 , pp. 1647-1670
    • Stevenson, W.G.1    Khan, H.2    Sager, P.3
  • 3
    • 0037065851 scopus 로고    scopus 로고
    • Isthmus characteristics of reentrant ventricular tachycardia after myocardial infarction
    • de Chillou C, Lacroix D, Klug D, et al.: Isthmus characteristics of reentrant ventricular tachycardia after myocardial infarction. Circulation 2002, 105:726-731.
    • (2002) Circulation , vol.105 , pp. 726-731
    • de Chillou, C.1    Lacroix, D.2    Klug, D.3
  • 4
    • 0023511484 scopus 로고
    • Neodymium: YAG laser photocoagulation: A successful new map-guided technique for the intraoperative ablation of ventricular tachycardia
    • Svenson RH, Gallagher JJ, Selle JG, et al.: Neodymium: YAG laser photocoagulation: a successful new map-guided technique for the intraoperative ablation of ventricular tachycardia. Circulation 1987, 76:1319-1328.
    • (1987) Circulation , vol.76 , pp. 1319-1328
    • Svenson, R.H.1    Gallagher, J.J.2    Selle, J.G.3
  • 5
    • 0034084886 scopus 로고    scopus 로고
    • Nonsurgical transthoracic epicardial catheter ablation to treat recurrent ventricular tachycardia occurring late after myocardial infarction
    • [see comments]
    • Sosa E, Scanavacca M, d'Avila A, et al.: Nonsurgical transthoracic epicardial catheter ablation to treat recurrent ventricular tachycardia occurring late after myocardial infarction [see comments]. J Am Coll Cardiol 2000, 35:1442-1449.
    • (2000) J. Am. Coll. Cardiol. , vol.35 , pp. 1442-1449
    • Sosa, E.1    Scanavacca, M.2    d'Avila, A.3
  • 6
    • 0035822636 scopus 로고    scopus 로고
    • Catheter ablation in patients with multiple and unstable ventricular tachycardias after myocardial infarction: Short ablation lines guided by reentry circuit isthmuses and sinus rhythm mapping
    • Soejima K, Suzuki M, Maisel WH, et al.: Catheter ablation in patients with multiple and unstable ventricular tachycardias after myocardial infarction: short ablation lines guided by reentry circuit isthmuses and sinus rhythm mapping. Circulation 2001, 104:664-669.
    • (2001) Circulation , vol.104 , pp. 664-669
    • Soejima, K.1    Suzuki, M.2    Maisel, W.H.3
  • 7
    • 16944364215 scopus 로고    scopus 로고
    • Comparison of effective and ineffective target sites that demonstrate concealed entrainment in patients with coronary artery disease undergoing radiofrequency ablation of ventricular tachycardia
    • Bogun F, Bahu M, Knight BP, et al.: Comparison of effective and ineffective target sites that demonstrate concealed entrainment in patients with coronary artery disease undergoing radiofrequency ablation of ventricular tachycardia. Circulation 1997, 95:183-190.
    • (1997) Circulation , vol.95 , pp. 183-190
    • Bogun, F.1    Bahu, M.2    Knight, B.P.3
  • 8
    • 3142765866 scopus 로고    scopus 로고
    • Recognition of far-field electrograms during entrainment mapping of ventricular tachycardia
    • Tung S, Stevenson WG, Soejima S, et al.: Recognition of far-field electrograms during entrainment mapping of ventricular tachycardia. J Am Coll Cardiol 2003, 111:1211.
    • (2003) J. Am. Coll. Cardiol. , vol.111 , pp. 1211
    • Tung, S.1    Stevenson, W.G.2    Soejima, S.3
  • 9
    • 0034884358 scopus 로고    scopus 로고
    • Catheter ablation of ventricular tachycardia in patients with coronary heart disease: Part I: Mapping
    • Delacretaz E, Stevenson WG: Catheter ablation of ventricular tachycardia in patients with coronary heart disease: part I: mapping. Pacing Clin Electrophysiol 2001, 24:1261-1277.
    • (2001) Pacing Clin. Electrophysiol. , vol.24 , pp. 1261-1277
    • Delacretaz, E.1    Stevenson, W.G.2
  • 10
    • 0034077896 scopus 로고    scopus 로고
    • Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy: Results of a prospective multicenter study. Cooled RF Multi Center Investigators Group
    • Calkins H, Epstein A, Packer D, et al.: Catheter ablation of ventricular tachycardia in patients with structural heart disease using cooled radiofrequency energy: results of a prospective multicenter study. Cooled RF Multi Center Investigators Group. J Am Coll Cardiol 2000, 35:1905-1914.
    • (2000) J. Am. Coll. Cardiol. , vol.35 , pp. 1905-1914
    • Calkins, H.1    Epstein, A.2    Packer, D.3
  • 11
    • 0036522222 scopus 로고    scopus 로고
    • Catheter ablation and antiarrhythmic drugs for haemodynamically tolerated post-infarction ventricular tachycardia; long-term outcome in relation to acute electrophysiological findings
    • Della Bella P, De Ponti R, Uriarte JA, et al.: Catheter ablation and antiarrhythmic drugs for haemodynamically tolerated post-infarction ventricular tachycardia; long-term outcome in relation to acute electrophysiological findings. Eur Heart J 2002, 23:414-424.
    • (2002) Eur. Heart J. , vol.23 , pp. 414-424
    • Della Bella, P.1    De Ponti, R.2    Uriarte, J.A.3
  • 12
    • 0027745366 scopus 로고
    • The Multicentre European Radiofrequency Survey (MERFS): Complications of radiofrequency catheter ablation of arrhythmias
    • The Multicentre European Radiofrequency Survey (MERFS) investigators of the Working Group on Arrhythmias of the European Society of Cardiology [see comments]
    • Hindricks G: The Multicentre European Radiofrequency Survey (MERFS): complications of radiofrequency catheter ablation of arrhythmias. The Multicentre European Radiofrequency Survey (MERFS) investigators of the Working Group on Arrhythmias of the European Society of Cardiology [see comments]. Eur Heart J 1993, 14:1644-1653.
    • (1993) Eur. Heart J. , vol.14 , pp. 1644-1653
    • Hindricks, G.1
  • 13
    • 0034696530 scopus 로고    scopus 로고
    • Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy
    • Marchlinski FE, Callans DJ, Gottlieb CD, et al.: Linear ablation lesions for control of unmappable ventricular tachycardia in patients with ischemic and nonischemic cardiomyopathy. Circulation 2000, 101:1288-1296.
    • (2000) Circulation , vol.101 , pp. 1288-1296
    • Marchlinski, F.E.1    Callans, D.J.2    Gottlieb, C.D.3
  • 14
    • 0033584723 scopus 로고    scopus 로고
    • Electroanatomic left ventricular mapping in the porcine model of healed anterior myocardial infarction: Correlation with intracardiac echocardiography and pathological analysis
    • Callans DJ, Ren JF, Michele J, et al.: Electroanatomic left ventricular mapping in the porcine model of healed anterior myocardial infarction: correlation with intracardiac echocardiography and pathological analysis. Circulation 1999, 100:1744-1750.
    • (1999) Circulation , vol.100 , pp. 1744-1750
    • Callans, D.J.1    Ren, J.F.2    Michele, J.3
  • 15
    • 0032506185 scopus 로고    scopus 로고
    • Electromechanical characterization of chronic myocardial infarction in the canine coronary occlusion model
    • Gepstein L, Goldin A, Lessick J, et al.: Electromechanical characterization of chronic myocardial infarction in the canine coronary occlusion model. Circulation 1998, 98:2055-2064.
    • (1998) Circulation , vol.98 , pp. 2055-2064
    • Gepstein, L.1    Goldin, A.2    Lessick, J.3
  • 16
    • 0028900907 scopus 로고
    • Effect of subendocardial resection on sinus rhythm endocardial electrogram abnormalities
    • Miller JM, Tyson GS, Hargrove WC 3rd, et al.: Effect of subendocardial resection on sinus rhythm endocardial electrogram abnormalities. Circulation 1995, 91:2385-2391.
    • (1995) Circulation , vol.91 , pp. 2385-2391
    • Miller, J.M.1    Tyson, G.S.2    Hargrove III, W.C.3
  • 17
    • 0029097778 scopus 로고
    • Relation of pace mapping QRS configuration and conduction delay to ventricular tachycardia reentry circuits in human infarct scars
    • Stevenson WG, Sager PT, Natterson PD, et al.: Relation of pace mapping QRS configuration and conduction delay to ventricular tachycardia reentry circuits in human infarct scars. J Am Coll Cardiol 1995, 26:481-488.
    • (1995) J. Am. Coll. Cardiol. , vol.26 , pp. 481-488
    • Stevenson, W.G.1    Sager, P.T.2    Natterson, P.D.3
  • 18
    • 0023525783 scopus 로고
    • Localization of slow conduction in a ventricular tachycardia circuit: Implications for catheter ablation
    • Stevenson WG, Weiss J, Wiener I, et al.: Localization of slow conduction in a ventricular tachycardia circuit: implications for catheter ablation. Am Heart J 1987, 114:1253-1258.
    • (1987) Am. Heart J. , vol.114 , pp. 1253-1258
    • Stevenson, W.G.1    Weiss, J.2    Wiener, I.3
  • 19
    • 0037420096 scopus 로고    scopus 로고
    • Relationship of slow conduction detected by pace-mapping to ventricular tachycardia reentry circuit sites after infarction
    • Brunckhorst CB, Stevenson WG, Soejima K, et al.: Relationship of slow conduction detected by pace-mapping to ventricular tachycardia reentry circuit sites after infarction. J Am Coll Cardiol 2003, 41:802-809.
    • (2003) J. Am. Coll. Cardiol. , vol.41 , pp. 802-809
    • Brunckhorst, C.B.1    Stevenson, W.G.2    Soejima, K.3
  • 20
    • 0037167690 scopus 로고    scopus 로고
    • Electrically unexcitable scar mapping based on pacing threshold for identification of the reentry circuit isthmus: Feasibility for guiding ventricular tachycardia ablation
    • Soejima K, Stevenson WG, Maisel WH, et al.: Electrically unexcitable scar mapping based on pacing threshold for identification of the reentry circuit isthmus: feasibility for guiding ventricular tachycardia ablation. Circulation 2002, 106:1678-1683.
    • (2002) Circulation , vol.106 , pp. 1678-1683
    • Soejima, K.1    Stevenson, W.G.2    Maisel, W.H.3
  • 21
    • 0036968361 scopus 로고    scopus 로고
    • Effect of radiofrequency catheter ablation of ventricular tachycardia on left ventricular function in patients with prior myocardial infarction
    • Khan HH, Maisel WH, Ho C, et al.: Effect of radiofrequency catheter ablation of ventricular tachycardia on left ventricular function in patients with prior myocardial infarction. J Interven Cardiol Electrphysiol 2002, 7:243-247.
    • (2002) J. Interven. Cardiol. Electrphysiol. , vol.7 , pp. 243-247
    • Khan, H.H.1    Maisel, W.H.2    Ho, C.3
  • 22
    • 0033580599 scopus 로고    scopus 로고
    • Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia
    • Schilling RJ, Peters NS, Davies DW: Feasibility of a noncontact catheter for endocardial mapping of human ventricular tachycardia. Circulation 1999, 99:2543-2552.
    • (1999) Circulation , vol.99 , pp. 2543-2552
    • Schilling, R.J.1    Peters, N.S.2    Davies, D.W.3
  • 23
    • 0034005801 scopus 로고    scopus 로고
    • Mapping and ablation of ventricular tachycardia guided by virtual electrograms using a noncontact, computerized mapping system
    • Strickberger SA, Knight BP, Michaud GF, et al.: Mapping and ablation of ventricular tachycardia guided by virtual electrograms using a noncontact, computerized mapping system. J Am Coll Cardiol 2000, 35:414-421.
    • (2000) J. Am. Coll. Cardiol. , vol.35 , pp. 414-421
    • Strickberger, S.A.1    Knight, B.P.2    Michaud, G.F.3
  • 24
    • 0036558597 scopus 로고    scopus 로고
    • Non-contact mapping to guide catheter ablation of untolerated ventricular tachycardia
    • Della Bella P, Pappalardo A, Riva S, et al.: Non-contact mapping to guide catheter ablation of untolerated ventricular tachycardia. Eur Heart J 2002, 23:742-752.
    • (2002) Eur. Heart J. , vol.23 , pp. 742-752
    • Della Bella, P.1    Pappalardo, A.2    Riva, S.3
  • 25
    • 0035836538 scopus 로고    scopus 로고
    • Saline-cooled versus standard radiofrequency catheter ablation for infarct-related ventricular tachycardias
    • Soejima K, Delacretaz E, Suzuki M, et al.: Saline-cooled versus standard radiofrequency catheter ablation for infarct-related ventricular tachycardias. Circulation 2001, 103:1858-1862.
    • (2001) Circulation , vol.103 , pp. 1858-1862
    • Soejima, K.1    Delacretaz, E.2    Suzuki, M.3
  • 26
    • 0029977234 scopus 로고    scopus 로고
    • A new technique to perform epicardial mapping in the electrophysiology laboratory
    • [see comments]
    • Sosa E, Scanavacca M, d'Avila A, et al.: A new technique to perform epicardial mapping in the electrophysiology laboratory [see comments]. J Cardiovasc Electrophysiol 1996, 7:531-536.
    • (1996) J. Cardiovasc. Electrophysiol. , vol.7 , pp. 531-536
    • Sosa, E.1    Scanavacca, M.2    d'Avila, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.