메뉴 건너뛰기




Volumn 29, Issue 9, 2003, Pages 567-575

Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: Value of the safety quotient

Author keywords

[No Author keywords available]

Indexed keywords

STAINLESS STEEL; BIOMEDICAL AND DENTAL MATERIALS; DENTAL ALLOY; NICKEL; TITANIUM; TITANIUM NICKELIDE;

EID: 0642279783     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004770-200309000-00007     Document Type: Article
Times cited : (86)

References (20)
  • 1
    • 0016052927 scopus 로고
    • Cleaning and shaping the root canal
    • Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18:269-96.
    • (1974) Dent Clin North Am , vol.18 , pp. 269-296
    • Schilder, H.1
  • 2
    • 0018528053 scopus 로고
    • The influence of the method of canal preparation on the quality of apical and coronal obturation
    • Allison DA, Weber CR, Walton RE. The influence of the method of canal preparation on the quality of apical and coronal obturation. J Endodon 1979;5:298-304.
    • (1979) J Endodon , vol.5 , pp. 298-304
    • Allison, D.A.1    Weber, C.R.2    Walton, R.E.3
  • 3
    • 0141902992 scopus 로고    scopus 로고
    • Cleaning and shaping root canal systems
    • Cohen S, Burns RC, eds. St. Louis: CV Mosby
    • Ruddle CJ. Cleaning and shaping root canal systems. In: Cohen S, Burns RC, eds. Pathways of the pulp. 8th ed. St. Louis: CV Mosby, 2002;231-91.
    • (2002) Pathways of the Pulp. 8th Ed. , pp. 231-291
    • Ruddle, C.J.1
  • 4
    • 0020346392 scopus 로고
    • Instrumentation of root canals in molars using the step-down technique
    • Goerig AC, Michelich RJ, Schultz HH. Instrumentation of root canals in molars using the step-down technique. J Endodon 1982;8:550-7.
    • (1982) J Endodon , vol.8 , pp. 550-557
    • Goerig, A.C.1    Michelich, R.J.2    Schultz, H.H.3
  • 5
    • 0021504864 scopus 로고
    • An evaluation of the crown-down pressureless technique
    • Morgan LF, Montgomery S. An evaluation of the crown-down pressureless technique. J Endodon 1984;10:491-8.
    • (1984) J Endodon , vol.10 , pp. 491-498
    • Morgan, L.F.1    Montgomery, S.2
  • 6
    • 0022068379 scopus 로고
    • The balanced force concept for instrumentation of curved canals
    • Roane JB, Sabala CL, Duncanson MG. The balanced force concept for instrumentation of curved canals. J Endodon 1985;11:203-11.
    • (1985) J Endodon , vol.11 , pp. 203-211
    • Roane, J.B.1    Sabala, C.L.2    Duncanson, M.G.3
  • 7
    • 0025103453 scopus 로고
    • Comparison of balanced forces, endosonic, and stepback filing instrumentation techniques: Quantification of extruded apical debris
    • McKendry DJ. Comparison of balanced forces, endosonic, and stepback filing instrumentation techniques: quantification of extruded apical debris. J Endodon 1990;16:24-7.
    • (1990) J Endodon , vol.16 , pp. 24-27
    • McKendry, D.J.1
  • 8
    • 0031197167 scopus 로고    scopus 로고
    • A comparison of canal centering ability of our instrumentation techniques
    • Short JA, Morgan LA, Baumgartner JC. A comparison of canal centering ability of our instrumentation techniques. J Endodon 1997;23:503-7.
    • (1997) J Endodon , vol.23 , pp. 503-507
    • Short, J.A.1    Morgan, L.A.2    Baumgartner, J.C.3
  • 9
    • 2442533275 scopus 로고    scopus 로고
    • Nonsurgical endodontic retreatment
    • Cohen S, Burns RC, eds. St. Louis: CV Mosby
    • Ruddle CJ. Nonsurgical endodontic retreatment. In: Cohen S, Burns RC, eds. Pathways of the pulp. 8th ed. St. Louis: CV Mosby, 2002:875-929.
    • (2002) Pathways of the Pulp. 8th Ed. , pp. 875-929
    • Ruddle, C.J.1
  • 10
    • 0024052338 scopus 로고
    • An initial investigation of the bending and torsional properties of nitinol root canal files
    • Walia H, Brantley WA, Gerstein H. An initial investigation of the bending and torsional properties of nitinol root canal files. J Endodon 1988;14:346-57.
    • (1988) J Endodon , vol.14 , pp. 346-357
    • Walia, H.1    Brantley, W.A.2    Gerstein, H.3
  • 11
    • 0026166609 scopus 로고
    • Dynamic fracture of hybrid endodontic hand instrument compared with traditional files
    • Haikel Y, Gasser P, Allemann C. Dynamic fracture of hybrid endodontic hand instrument compared with traditional files. J Endodon 1991;17:217-21.
    • (1991) J Endodon , vol.17 , pp. 217-221
    • Haikel, Y.1    Gasser, P.2    Allemann, C.3
  • 12
    • 0028490836 scopus 로고
    • Torsional and stiffness properties of Canal Master U stainless steel and nitinol instruments
    • Camps J, Pertot WJ. Torsional and stiffness properties of Canal Master U stainless steel and nitinol instruments. J Endodon 1994;8:395-8.
    • (1994) J Endodon , vol.8 , pp. 395-398
    • Camps, J.1    Pertot, W.J.2
  • 13
    • 0031064647 scopus 로고    scopus 로고
    • Cyclic fatigue testing of nickel-titanium endodontics instruments
    • Pruett JP, Clement DJ, Carnes DL. Cyclic fatigue testing of nickel-titanium endodontics instruments. J Endodon 1997;23:77-85.
    • (1997) J Endodon , vol.23 , pp. 77-85
    • Pruett, J.P.1    Clement, D.J.2    Carnes, D.L.3
  • 14
    • 0031064241 scopus 로고    scopus 로고
    • Analysis of forces developed during obturations: Warm vertical compaction
    • Blum JY, Parahy E, Micallef JP. Analysis of forces developed during obturations: warm vertical compaction. J Endodon 1997;2:91-6.
    • (1997) J Endodon , vol.2 , pp. 91-96
    • Blum, J.Y.1    Parahy, E.2    Micallef, J.P.3
  • 15
    • 0031268055 scopus 로고    scopus 로고
    • Analysis of forces developed during root canal preparation with the balanced force technique
    • Blum JY, Machtou P, Esber S, Micallef JP. Analysis of forces developed during root canal preparation with the balanced force technique. Int Endod J 1997;30:386-96.
    • (1997) Int Endod J , vol.30 , pp. 386-396
    • Blum, J.Y.1    Machtou, P.2    Esber, S.3    Micallef, J.P.4
  • 16
    • 0034157104 scopus 로고    scopus 로고
    • Torque during canal instrumentation using rotary nickel-titanium files
    • Sattapan B, Palamara JEA, Messer HH. Torque during canal instrumentation using rotary nickel-titanium files J Endodon 2000;26:156-60.
    • (2000) J Endodon , vol.26 , pp. 156-160
    • Sattapan, B.1    Palamara, J.E.A.2    Messer, H.H.3
  • 18
    • 0032152422 scopus 로고    scopus 로고
    • Endodontic canal preparation: Advances in rotary instrumentation
    • Machtou P. Endodontic canal preparation: advances in rotary instrumentation. Pract Periodontics Aesthet Dent 1997;10:937-40.
    • (1997) Pract Periodontics Aesthet Dent , vol.10 , pp. 937-940
    • Machtou, P.1
  • 19
    • 0032610007 scopus 로고    scopus 로고
    • Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments
    • Blum JY, Cohen A, Machtou P, Micallef JP. Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments. Int Endod J 1999;32:24-31.
    • (1999) Int Endod J , vol.32 , pp. 24-31
    • Blum, J.Y.1    Cohen, A.2    Machtou, P.3    Micallef, J.P.4
  • 20
    • 0033091907 scopus 로고    scopus 로고
    • Location of contact areas on rotary Profile instruments in relationship to the forces developed during mechanical preparation on extracted teeth
    • Blum JY, Machtou P, Micallef JP. Location of contact areas on rotary Profile instruments in relationship to the forces developed during mechanical preparation on extracted teeth. Int Endod J 1999;32:108-14.
    • (1999) Int Endod J , vol.32 , pp. 108-114
    • Blum, J.Y.1    Machtou, P.2    Micallef, J.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.