-
1
-
-
0000383767
-
Detection of desterolized sunflower oil in olive oil through isomerized △7-sterols
-
Biedermann, M.; Grob, K.; Mariani, C.; Schmidt, J. P. Detection of desterolized sunflower oil in olive oil through isomerized △7-sterols. Z. Lebensm. Unters. Forsch. 1996, 202, 199-204.
-
(1996)
Z. Lebensm. Unters. Forsch.
, vol.202
, pp. 199-204
-
-
Biedermann, M.1
Grob, K.2
Mariani, C.3
Schmidt, J.P.4
-
2
-
-
0027534041
-
Preconcentration of volatile components of foods: Optimization of the steam distillation-solvent extraction at normal pressure
-
Blanch, G. P.; Tabera, J.; Herraiz, M.; Reglero, G. Preconcentration of volatile components of foods: optimization of the steam distillation-solvent extraction at normal pressure. J. Chromatogr. 1993a, 628, 261-8.
-
(1993)
J. Chromatogr.
, vol.628
, pp. 261-268
-
-
Blanch, G.P.1
Tabera, J.2
Herraiz, M.3
Reglero, G.4
-
3
-
-
0027744385
-
Preconcentration of samples by steam distillation-solvent extraction at low temperature
-
Blanch, G. P.; Herraiz, M.; Reglero, G.; Tabera, J. Preconcentration of samples by steam distillation-solvent extraction at low temperature. J. Chromatogr. A 1993b, 655, 141-49.
-
(1993)
J. Chromatogr. A
, vol.655
, pp. 141-149
-
-
Blanch, G.P.1
Herraiz, M.2
Reglero, G.3
Tabera, J.4
-
5
-
-
0026940088
-
Rapid analysis of whey proteins from different animal species by reversed-phase high-performance liquid chromatography
-
de Frutos, M.; Cifuentes, A.; Amigo, L.; Ramos, M.; Diez-Masa, J. C. Rapid analysis of whey proteins from different animal species by reversed-phase high-performance liquid chromatography. Z. Lebensm. Unters. -Forsch. 1992, 195, 326-31.
-
(1992)
Z. Lebensm. Unters. -Forsch.
, vol.195
, pp. 326-331
-
-
De Frutos, M.1
Cifuentes, A.2
Amigo, L.3
Ramos, M.4
Diez-Masa, J.C.5
-
6
-
-
0000485722
-
Simplex optimization of variables in analytical chemistry
-
Deming, S. N.; Morgan, S. L. Simplex optimization of variables in analytical chemistry. Anal. Chem. 1973, 45, 278A-83A.
-
(1973)
Anal. Chem.
, vol.45
-
-
Deming, S.N.1
Morgan, S.L.2
-
7
-
-
84986774165
-
Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography. II. Use of a solvent vapor exit to increase introduction volumes and introduction rates into the gas Chromatograph
-
Goosens, E. C.; de Jong, D.; de Jong, G. J.; Brinkman, U. A. Th. Reversed-phase liquid chromatography coupled on-line with capillary gas chromatography. II. Use of a solvent vapor exit to increase introduction volumes and introduction rates into the gas Chromatograph. J. Microcolumn Sep. 1994, 6, 207-15.
-
(1994)
J. Microcolumn Sep.
, vol.6
, pp. 207-215
-
-
Goosens, E.C.1
De Jong, D.2
De Jong, G.J.3
Brinkman, U.A.Th.4
-
9
-
-
0027085792
-
Hypenated high-performance liquid chromatography-capillary gas chromatography
-
Grob, K. Hypenated high-performance liquid chromatography-capillary gas chromatography. J. Chromatogr. 1992, 626, 25-32.
-
(1992)
J. Chromatogr.
, vol.626
, pp. 25-32
-
-
Grob, K.1
-
10
-
-
0029052192
-
Development of the transfer techniques for on-line high-performance liquid chromatography-capillary gas chromatography
-
Grob, K. Development of the transfer techniques for on-line high-performance liquid chromatography-capillary gas chromatography. J. Chromatogr. 1995, 703, 265-76.
-
(1995)
J. Chromatogr.
, vol.703
, pp. 265-276
-
-
Grob, K.1
-
11
-
-
84986492823
-
Reproducibility of results from LC-GC of sterols and wax esters in olive oil
-
Grob, K.; Lanfranchi, M. Reproducibility of results from LC-GC of sterols and wax esters in olive oil. J. High Resolut. Chromatogr. 1989, 12, 624-26.
-
(1989)
J. High Resolut. Chromatogr.
, vol.12
, pp. 624-626
-
-
Grob, K.1
Lanfranchi, M.2
-
12
-
-
0000480272
-
Determination of free and esterified sterols and of wax esters in oils and fats by coupled liquid chromatography-gas chromatography
-
Grob, K.; Lanfranchi, M.; Mariani, C. Determination of free and esterified sterols and of wax esters in oils and fats by coupled liquid chromatography-gas chromatography. J. Chromatogr. 1989, 471, 397-405.
-
(1989)
J. Chromatogr.
, vol.471
, pp. 397-405
-
-
Grob, K.1
Lanfranchi, M.2
Mariani, C.3
-
13
-
-
0025508177
-
Evaluation of olive oil through the fatty alcohols, the sterols and their esters by coupled LC-GC
-
Grob, K.; Lanfranchi, M.; Mariani, C. Evaluation of olive oil through the fatty alcohols, the sterols and their esters by coupled LC-GC. J. Am. Oil Chem. Soc. 1990, 67, 626-34.
-
(1990)
J. Am. Oil Chem. Soc.
, vol.67
, pp. 626-634
-
-
Grob, K.1
Lanfranchi, M.2
Mariani, C.3
-
14
-
-
0345876141
-
On-line HPLC-HRGC coupling and simultaneous transfer of two different LC fractions. Determination of aliphatic alcohols and sterols in olive oil
-
Lanuzza, F.; Micali, G.; Calabrò. G. On-line HPLC-HRGC coupling and simultaneous transfer of two different LC fractions. Determination of aliphatic alcohols and sterols in olive oil. J. High Resolut. Chromatogr. 1996, 19, 444-8.
-
(1996)
J. High Resolut. Chromatogr.
, vol.19
, pp. 444-448
-
-
Lanuzza, F.1
Micali, G.2
Calabrò, G.3
-
15
-
-
0027468194
-
Trace level analysis of micropollutants in aqueous samples using gas chromatography with on-line sample enrichment and large volume injection
-
Mol, H. G.; Staniewski, J.; Janssen, H. G.; Cramers, C. A.; Ghijsen, R. T.; Brinkman, U. A. Th. Trace level analysis of micropollutants in aqueous samples using gas chromatography with on-line sample enrichment and large volume injection. J. Chromatogr. 1993, 630, 201-12.
-
(1993)
J. Chromatogr.
, vol.630
, pp. 201-212
-
-
Mol, H.G.1
Staniewski, J.2
Janssen, H.G.3
Cramers, C.A.4
Ghijsen, R.T.5
Brinkman, U.A.Th.6
-
16
-
-
0002001441
-
Large volume sample introduction using temperature programmable injectors: Implications of liner diameter
-
Mol, H. G. J.; Janssen, H. G.; Cramers, C. A.; Brinkman, U. A. Th. Large volume sample introduction using temperature programmable injectors: Implications of liner diameter. J. High Resolut. Chromatogr. 1995a, 18, 19-27.
-
(1995)
J. High Resolut. Chromatogr.
, vol.18
, pp. 19-27
-
-
Mol, H.G.J.1
Janssen, H.G.2
Cramers, C.A.3
Brinkman, U.A.Th.4
-
17
-
-
84988072526
-
Large volume injection in capillary GC using PTV injectors: Comparison of inertness of packing materials
-
Mol, H. G. J.; Hendriks, P. J. M.; Janssen, H. G.; Cramers, C. A.; Brinkman, U. A. Th. Large volume injection in capillary GC using PTV injectors: Comparison of inertness of packing materials. J. High Resolut. Chromatogr. 1995b, 18, 124-8.
-
(1995)
J. High Resolut. Chromatogr.
, vol.18
, pp. 124-128
-
-
Mol, H.G.J.1
Hendriks, P.J.M.2
Janssen, H.G.3
Cramers, C.A.4
Brinkman, U.A.Th.5
-
18
-
-
84986773244
-
Automated LC-GC: A powerful method for essential oils analysis. Part IV. Coupled LC-GC-MS (ITD) for bergamot oil analysis
-
Mondello, L.; Bartle, K. D.; Dugo, P.; Gans, P..; Dugo, G. Automated LC-GC: A powerful method for essential oils analysis. Part IV. Coupled LC-GC-MS (ITD) for bergamot oil analysis. J. Microcolumn Sep. 1994, 6, 237-44.
-
(1994)
J. Microcolumn Sep.
, vol.6
, pp. 237-244
-
-
Mondello, L.1
Bartle, K.D.2
Dugo, P.3
Gans, P.4
Dugo, G.5
-
19
-
-
0001083047
-
On-line microbore high performance liquid chromatography-capillary gas chromatography for food and water analysis. A review
-
Mondello, L.; Dugo, G.; Bartle, K. D. On-line microbore high performance liquid chromatography-capillary gas chromatography for food and water analysis. A review. J. Microcolumn Sep. 1996a, 8, 275-310.
-
(1996)
J. Microcolumn Sep.
, vol.8
, pp. 275-310
-
-
Mondello, L.1
Dugo, G.2
Bartle, K.D.3
-
20
-
-
0001106162
-
On-line HPLC-HRGC-MS for the analysis of natural complex mixtures
-
Mondello, L.; Dugo, P.; Dugo, G.; Bartle, K. D. On-line HPLC-HRGC-MS for the analysis of natural complex mixtures. J. Chromatogr. Sci. 1996b, 34, 174-81.
-
(1996)
J. Chromatogr. Sci.
, vol.34
, pp. 174-181
-
-
Mondello, L.1
Dugo, P.2
Dugo, G.3
Bartle, K.D.4
-
21
-
-
0000238336
-
A simplex method for function minimization
-
Nedler, J. A.; Mead, R. A simplex method for function minimization. Comput. J. 1965, 7, 308-13.
-
(1965)
Comput. J.
, vol.7
, pp. 308-313
-
-
Nedler, J.A.1
Mead, R.2
-
22
-
-
85034473890
-
-
Jan 29, EEC Regulation 183/ 93 of Jan 29, 1993
-
Official Journal of the European Communities, Off. J. Eur. Communities 1988 (Jan 29), L22, 58 (EEC Regulation 183/ 93 of Jan 29, 1993).
-
(1988)
Off. J. Eur. Communities
, vol.L22
, pp. 58
-
-
-
23
-
-
0030144453
-
Kinetic evaluation of 3,β-hidroxychoIest-5-en-7-one (7-Ketocholesterol) stability during saponification
-
Park, P. W.; Guardiola, F.; Park, S. H.; Addis, P. B. Kinetic evaluation of 3,β-hidroxychoIest-5-en-7-one (7-Ketocholesterol) stability during saponification. J. Am. Oil Chem. Soc. 1996, 73, 623-29.
-
(1996)
J. Am. Oil Chem. Soc.
, vol.73
, pp. 623-629
-
-
Park, P.W.1
Guardiola, F.2
Park, S.H.3
Addis, P.B.4
-
25
-
-
0003157443
-
Automatic injection in high-resolution gas chromatography. A programmed temperature vaporizer as a general purpose injection system
-
Poy, F.; Visani, S.; Terrosi, F. Automatic injection in high-resolution gas chromatography. A programmed temperature vaporizer as a general purpose injection system. J. Chromatogr. 1981, 217, 81-90.
-
(1981)
J. Chromatogr.
, vol.217
, pp. 81-90
-
-
Poy, F.1
Visani, S.2
Terrosi, F.3
-
26
-
-
0010650795
-
Sampling systems in capillary chromatography
-
Kaiser, R. E., Ed.; Hüthig: Heidelberg, Germany
-
Schomburg, G. Sampling systems in capillary chromatography. In Proceedings of the 4th International Symposium on Capillary Chromatography, Hindelang; Kaiser, R. E., Ed.; Hüthig: Heidelberg, Germany, 1981; pp 371-4.
-
(1981)
Proceedings of the 4th International Symposium on Capillary Chromatography, Hindelang
, pp. 371-374
-
-
Schomburg, G.1
-
27
-
-
0027361324
-
Variables affecting the introduction of large sample volumes in capillary gas chromatography using a programmed-temperature vaporizer
-
Señoráns, F. J.; Tabera, J.; Villén, J.; Herraiz, M.; Reglero, G. Variables affecting the introduction of large sample volumes in capillary gas chromatography using a programmed-temperature vaporizer. J. Chromatogr. 1993, 648, 407-14.
-
(1993)
J. Chromatogr.
, vol.648
, pp. 407-414
-
-
Señoráns, F.J.1
Tabera, J.2
Villén, J.3
Herraiz, M.4
Reglero, G.5
-
28
-
-
0010650427
-
Use of a programmed temperature injector for on-line reversed phase liquid chromatography-capillary gas chromatography
-
Señoráns, F. J.; Reglero, G.; Herraiz, M. Use of a programmed temperature injector for on-line reversed phase liquid chromatography-capillary gas chromatography. J. Chromatogr. Sci. 1995a, 33, 446-50.
-
(1995)
J. Chromatogr. Sci.
, vol.33
, pp. 446-450
-
-
Señoráns, F.J.1
Reglero, G.2
Herraiz, M.3
-
29
-
-
84988099685
-
On-line reversed phase liquid chromatography-capillary gas chromatography using a programmed temperature vaporizer as interface
-
Señoráns, F. J.; Herraiz, M.; Tabera, J. On-line reversed phase liquid chromatography-capillary gas chromatography using a programmed temperature vaporizer as interface. J. High Resolut. Chromatogr. 1995b, 18, 433-38.
-
(1995)
J. High Resolut. Chromatogr.
, vol.18
, pp. 433-438
-
-
Señoráns, F.J.1
Herraiz, M.2
Tabera, J.3
-
30
-
-
0040022062
-
Rapid separation of free sterols in edible oils by on-line coupled reversed phase liquid chromatography-gas chromatography
-
Señoráns, F. J.; Tabera, J.; Herraiz, M. Rapid separation of free sterols in edible oils by on-line coupled reversed phase liquid chromatography-gas chromatography. J. Agric. Food Chem. 1996, 44, 3189-92.
-
(1996)
J. Agric. Food Chem.
, vol.44
, pp. 3189-3192
-
-
Señoráns, F.J.1
Tabera, J.2
Herraiz, M.3
-
31
-
-
84946640734
-
Sequential application of simplex design in optimization and evolutionary operation
-
Spendley, W.; Hext, G. R.; Himsworth, F. R. Sequential application of simplex design in optimization and evolutionary operation. Technometrics 1962, 4, 441.
-
(1962)
Technometrics
, vol.4
, pp. 441
-
-
Spendley, W.1
Hext, G.R.2
Himsworth, F.R.3
-
32
-
-
84988057751
-
Potential and limitations of differently designed programmed temperature injector liners for large volume sample introduction in capillary GC
-
Staniewski, J.; Rijks, J. A. Potential and limitations of differently designed programmed temperature injector liners for large volume sample introduction in capillary GC. J. High Resolut. Chromatogr. 1993, 16, 182-7.
-
(1993)
J. High Resolut. Chromatogr.
, vol.16
, pp. 182-187
-
-
Staniewski, J.1
Rijks, J.A.2
-
33
-
-
84986765094
-
Programmed-temperature injector for large-volume sample introduction in capillary gas chromatography and for liquid chromatography-gas chromatography interfacing
-
Staniewski, J.; Janssen, H. G.; Cramers, C. A..; Rijks, J. A. Programmed-temperature injector for large-volume sample introduction in capillary gas chromatography and for liquid chromatography-gas chromatography interfacing. J. Microcolumn Sep. 1992, 4, 331-8.
-
(1992)
J. Microcolumn Sep.
, vol.4
, pp. 331-338
-
-
Staniewski, J.1
Janssen, H.G.2
Cramers, C.A.3
Rijks, J.A.4
-
35
-
-
0026897512
-
Experimental design optimization of large volume sampling in a programmed temperature vaporizer
-
Villén, J.; Señoráns, F. J.; Herraiz, M.; Reglero, G.; Tabera, J. Experimental design optimization of large volume sampling in a programmed temperature vaporizer. J. Chromatogr. Sci. 1992, 30, 261-6.
-
(1992)
J. Chromatogr. Sci.
, vol.30
, pp. 261-266
-
-
Villén, J.1
Señoráns, F.J.2
Herraiz, M.3
Reglero, G.4
Tabera, J.5
-
36
-
-
0000152897
-
Capillary gas Chromatographic injection system for large sample volumes
-
Vogt, W.; Jacob, K; Ohnesorge, A.; Obwexer, H. W. Capillary gas Chromatographic injection system for large sample volumes. J. Chromatogr. 1979, 186, 197-205.
-
(1979)
J. Chromatogr.
, vol.186
, pp. 197-205
-
-
Vogt, W.1
Jacob, K.2
Ohnesorge, A.3
Obwexer, H.W.4
-
37
-
-
84985225002
-
On-line solid-phase extraction-thermal desorption for introduction of large volumes of aqueous samples into a gas Chromatograph
-
Vreuls, J. J.; Brinkman, U. A. Th.; de Jong, G. J.; Grob, K.; Artho, A. On-line solid-phase extraction-thermal desorption for introduction of large volumes of aqueous samples into a gas Chromatograph. J. High Resolut. Chromatogr. 1991, 14, 455-9.
-
(1991)
J. High Resolut. Chromatogr.
, vol.14
, pp. 455-459
-
-
Vreuls, J.J.1
Brinkman, U.A.Th.2
De Jong, G.J.3
Grob, K.4
Artho, A.5
-
38
-
-
0000970556
-
Liquid chromatography coupled on-line with gas chromatography: State of the art
-
Vreuls, J. J.; de Jong, G. J.; Ghijsen, R. T.; Brinkman, U. A. Th. Liquid chromatography coupled on-line with gas chromatography: State of the art. J. AOAC Int. 1994, 77, 306-27.
-
(1994)
J. AOAC Int.
, vol.77
, pp. 306-327
-
-
Vreuls, J.J.1
De Jong, G.J.2
Ghijsen, R.T.3
Brinkman, U.A.Th.4
|