메뉴 건너뛰기




Volumn 111, Issue 1, 2004, Pages 107-117

A surface-tension-driven fluidic network for precise enzyme batch-dispensing and glucose detection

Author keywords

Glucose sensor; Micro fluidic network; Parallel dispensing; Polymer MEMS

Indexed keywords

BLOOD; DEPOSITION; ENZYME IMMOBILIZATION; GLUCOSE; GLUCOSE SENSORS; HEMODYNAMICS; HYDROPHILICITY; MICROELECTROMECHANICAL DEVICES; SURFACE TENSION;

EID: 0442311889     PISSN: 09244247     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.sna.2003.10.028     Document Type: Conference Paper
Times cited : (37)

References (8)
  • 3
    • 0031244908 scopus 로고    scopus 로고
    • Performance of amperometric sensors based on multiple microelectrode arrays
    • Morf W.E., de Rooij N.F. Performance of amperometric sensors based on multiple microelectrode arrays. Sens. Actuators B. 44:1997;538-541.
    • (1997) Sens. Actuators B , vol.44 , pp. 538-541
    • Morf, W.E.1    De Rooij, N.F.2
  • 4
    • 0031223016 scopus 로고    scopus 로고
    • Multianalyte sensor for the simultaneous determination of glucose, L-lactate and uric acid based on a microelectrode array
    • H. Frebel, G.c. Chemnitius, K. Cammann, R. Kakerow, M. Rospect, W. Mokwa, Multianalyte sensor for the simultaneous determination of glucose, L-lactate and uric acid based on a microelectrode array, Sens. Actuators B 43 (1997) 87-93.
    • (1997) Sens. Actuators B , vol.43 , pp. 87-93
    • Frebel, H.1    Chemnitius, G.C.2    Cammann, K.3    Kakerow, R.4    Rospect, M.5    Mokwa, W.6
  • 6
    • 0037480258 scopus 로고    scopus 로고
    • A power-free surface-tension-driven fluidic network system for large-array enzyme immobilization and glucose sensing
    • Kyoto, Japan, January 19-23
    • F.-G. Tseng, K.-H. Lin, H.-T. Hsu, Yu-H. Chang, C.-C. Chieng, A power-free surface-tension-driven fluidic network system for large-array enzyme immobilization and glucose sensing, in: Proceedings IEEE MEMS'03, Kyoto, Japan, January 19-23, 2003, pp. 419-422.
    • (2003) Proceedings IEEE MEMS'03 , pp. 419-422
    • Tseng, F.-G.1    Lin, K.-H.2    Hsu, H.-T.3    Chang, Yu.-H.4    Chieng, C.-C.5
  • 7
    • 0442289234 scopus 로고    scopus 로고
    • Novel liquid injection method with wedge-shaped microchannel on a PDMS microchip system for diagnostic analyses
    • Munich, Germany, June 10-14
    • R. Aoyama, M. Seki, J.W. Hong, T. Fujii, I. Endo, Novel liquid injection method with wedge-shaped microchannel on a PDMS microchip system for diagnostic analyses, IEEE Transducers'01, Munich, Germany, June 10-14, 2001.
    • (2001) IEEE Transducers'01
    • Aoyama, R.1    Seki, M.2    Hong, J.W.3    Fujii, T.4    Endo, I.5
  • 8
    • 0031682845 scopus 로고    scopus 로고
    • Microfabricated capillarity-driven stop valve and sample injector
    • Heidelberg, Germany, January 25-29
    • P.F. Man, C.H. Mastrangelo, M.A. Burns, D.T. Burke, Microfabricated capillarity-driven stop valve and sample injector, in: Proceedings of IEEE MEMS'98, Heidelberg, Germany, January 25-29, 1998, pp. 45-48.
    • (1998) Proceedings of IEEE MEMS'98 , pp. 45-48
    • Man, P.F.1    Mastrangelo, C.H.2    Burns, M.A.3    Burke, D.T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.