메뉴 건너뛰기




Volumn 111, Issue 2, 2004, Pages 103-108

Intrapartum ultrasound estimation of total bladder volume

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; BALLOON CATHETER; BALLOON DILATATION; BLADDER; BLADDER CAPACITY; BLADDER CATHETERIZATION; BLADDER DISTENSION; CATHETERIZATION; CESAREAN SECTION; CONTROLLED STUDY; ECHOGRAPHY; FEMALE; HUMAN; HUMAN EXPERIMENT; LABOR; LINEAR REGRESSION ANALYSIS; MATHEMATICAL ANALYSIS; METHODOLOGY; MIDWIFE; MULTIPARA; NORMAL HUMAN; NULLIPARA; PHYSIOLOGY; PREDICTION; PREGNANCY; PRIORITY JOURNAL; PROSPECTIVE STUDY; REAL TIME ECHOGRAPHY; SENSITIVITY AND SPECIFICITY; STANDARD; URINE; URINE VOLUME; UTERINE CERVIX DILATATION;

EID: 0442291987     PISSN: 14700328     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1471-0528.2003.51107.x-i1     Document Type: Article
Times cited : (18)

References (30)
  • 1
    • 0020625449 scopus 로고
    • Effect of lumbar epidural analgesia on lower urinary tract function in the immediate postpartum period
    • Weil A, Reyes H, Rottenberg RD, Beguin F, Hermann WI. Effect of lumbar epidural analgesia on lower urinary tract function in the immediate postpartum period. Br J Obstet Gynaecol 1983;90(5):428-432.
    • (1983) Br J Obstet Gynaecol , vol.90 , Issue.5 , pp. 428-432
    • Weil, A.1    Reyes, H.2    Rottenberg, R.D.3    Beguin, F.4    Hermann, W.I.5
  • 2
    • 0017160405 scopus 로고
    • Postoperative over distension of the bladder
    • Hinman F. Postoperative over distension of the bladder. Surg Gynecol Obstet 1976;142:901-902.
    • (1976) Surg Gynecol Obstet , vol.142 , pp. 901-902
    • Hinman, F.1
  • 3
    • 0040523073 scopus 로고
    • Dysuria in the dog
    • Holt PE. Dysuria in the dog. Vet Rec 1990:121-125, 147-153.
    • (1990) Vet Rec , pp. 121-125
    • Holt, P.E.1
  • 4
    • 0031957037 scopus 로고    scopus 로고
    • Effect of the duration of labour on postpartum postvoid residual bladder volume
    • Yip SK, Hin LY, Chung TK. Effect of the duration of labour on postpartum postvoid residual bladder volume. Gynecol Obstet Investig 1998;45(3):177-180.
    • (1998) Gynecol Obstet Investig , vol.45 , Issue.3 , pp. 177-180
    • Yip, S.K.1    Hin, L.Y.2    Chung, T.K.3
  • 5
    • 0029348854 scopus 로고
    • Postpartum surveillance of urinary retention by ultrasonography: The effect of epidural analgesia
    • Weissman A, Grisaru D, Shenhav M, Peyser RM, Jaffa AJ. Postpartum surveillance of urinary retention by ultrasonography: the effect of epidural analgesia. Ultrasound Obstet Gynecol 1995;6:130-134.
    • (1995) Ultrasound Obstet Gynecol , vol.6 , pp. 130-134
    • Weissman, A.1    Grisaru, D.2    Shenhav, M.3    Peyser, R.M.4    Jaffa, A.J.5
  • 6
    • 0017742384 scopus 로고
    • Postpartum surveillance for urinary tract infections: Patients at risk for developing pyelonephritis after catheterisation
    • Harris RE, Thomas VL, Jui GW. Postpartum surveillance for urinary tract infections: patients at risk for developing pyelonephritis after catheterisation. South Med J 1977;70:1273-1275.
    • (1977) South Med J , vol.70 , pp. 1273-1275
    • Harris, R.E.1    Thomas, V.L.2    Jui, G.W.3
  • 7
    • 0024432695 scopus 로고
    • Assessing the effectiveness of different urinary catheters on emptying the bladder and application of transvaginal ultrasound
    • October
    • Haylen BT, Frazer MI, MacDonald JH. Assessing the effectiveness of different urinary catheters on emptying the bladder and application of transvaginal ultrasound. Br J Urol 1989;64(4):353-356 (October).
    • (1989) Br J Urol , vol.64 , Issue.4 , pp. 353-356
    • Haylen, B.T.1    Frazer, M.I.2    MacDonald, J.H.3
  • 8
    • 0003357566 scopus 로고    scopus 로고
    • U. K. Guidelines for preventing infection associated with the insertion and maintenance of short-term indwelling urethral catheters in acute care
    • Department of Health. U. K. Guidelines for preventing infection associated with the insertion and maintenance of short-term indwelling urethral catheters in acute care. J Hosp Infect 2001;47(Supplement):S39-S46.
    • (2001) J Hosp Infect , vol.47 , Issue.SUPPL.
  • 9
    • 0016077323 scopus 로고
    • Determination of organ volume by means of ultrasound B-mode scanning
    • Doust BD, Baum JK, Maklad NF, Baum RF. Determination of organ volume by means of ultrasound B-mode scanning. JCU 1974;2(2):127-130.
    • (1974) JCU , vol.2 , Issue.2 , pp. 127-130
    • Doust, B.D.1    Baum, J.K.2    Maklad, N.F.3    Baum, R.F.4
  • 10
    • 0016790517 scopus 로고
    • Residual urine determination by ultrasonic scanning
    • Pederson JF, Bartum RJ, Grytter C. Residual urine determination by ultrasonic scanning. Am J Roentgenol 1975;125:474-478.
    • (1975) Am J Roentgenol , vol.125 , pp. 474-478
    • Pederson, J.F.1    Bartum, R.J.2    Grytter, C.3
  • 11
    • 0022004687 scopus 로고
    • Ultrasound assessment of residual urine. A quantitative method
    • Beacock CJ, Roberts EE, Rees RWM, Buck AC. Ultrasound assessment of residual urine. A quantitative method. Br J Urol 1985;57:410-413.
    • (1985) Br J Urol , vol.57 , pp. 410-413
    • Beacock, C.J.1    Roberts, E.E.2    Rees, R.W.M.3    Buck, A.C.4
  • 12
    • 0024561765 scopus 로고
    • Accuracy of total bladder volume and residual urine measurement: Comparison between real-time ultrasonography and catheterization
    • Mainprize TC, Drutz HP. Accuracy of total bladder volume and residual urine measurement: comparison between real-time ultrasonography and catheterization. J Am Obstet Gynecol 1989;160:1013-1016.
    • (1989) J Am Obstet Gynecol , vol.160 , pp. 1013-1016
    • Mainprize, T.C.1    Drutz, H.P.2
  • 13
    • 0020056255 scopus 로고
    • Ultrasonic assessment of residual urine volume
    • Rageth JC, Langer K. Ultrasonic assessment of residual urine volume. Urol Res 1982;10:57-60.
    • (1982) Urol Res , vol.10 , pp. 57-60
    • Rageth, J.C.1    Langer, K.2
  • 14
    • 0020635753 scopus 로고
    • The estimation of bladder volume by sonocystography
    • Hakenberg OW, Ryall RL, Marshall VR. The estimation of bladder volume by sonocystography. J Urol 1983;130:249-251.
    • (1983) J Urol , vol.130 , pp. 249-251
    • Hakenberg, O.W.1    Ryall, R.L.2    Marshall, V.R.3
  • 15
    • 0030498960 scopus 로고    scopus 로고
    • Measurement of residual urine volume using a portable ultrasound instrument
    • Fuse H, Yokoyama T, Muraishi Y, Katayama T. Measurement of residual urine volume using a portable ultrasound instrument. Int J Urol Nephrol 1996;28(5):633-637.
    • (1996) Int J Urol Nephrol , vol.28 , Issue.5 , pp. 633-637
    • Fuse, H.1    Yokoyama, T.2    Muraishi, Y.3    Katayama, T.4
  • 16
    • 0031861157 scopus 로고    scopus 로고
    • Ultrasonographic estimation of post-partum postvoid residual bladder volumes. A comparison between transabdominal and transvaginal ultrasonography
    • Yip SK, Fung TY, Chung TK. Ultrasonographic estimation of post-partum postvoid residual bladder volumes. A comparison between transabdominal and transvaginal ultrasonography. Int Urogynecol J 1998;9(1):9-12.
    • (1998) Int Urogynecol J , vol.9 , Issue.1 , pp. 9-12
    • Yip, S.K.1    Fung, T.Y.2    Chung, T.K.3
  • 17
    • 0032158745 scopus 로고    scopus 로고
    • Estimation of bladder volume using ultrasonographic determination of cross-sectional areas and linear measurements
    • Atalan G, Barr FJ, Holt PE. Estimation of bladder volume using ultrasonographic determination of cross-sectional areas and linear measurements. Vet Radiol Ultrasound 1998;39(5):446-450.
    • (1998) Vet Radiol Ultrasound , vol.39 , Issue.5 , pp. 446-450
    • Atalan, G.1    Barr, F.J.2    Holt, P.E.3
  • 18
    • 0029655596 scopus 로고    scopus 로고
    • Estimation of bladder volume using portable ultrasound in clam enteroplasty patients
    • Barrington JW, Jones A, Robinson J, Stephenson TP. Estimation of bladder volume using portable ultrasound in clam enteroplasty patients. J Urol 1996;155(1):82-83.
    • (1996) J Urol , vol.155 , Issue.1 , pp. 82-83
    • Barrington, J.W.1    Jones, A.2    Robinson, J.3    Stephenson, T.P.4
  • 19
    • 0019450416 scopus 로고
    • Application of bladder ultrasonography. Bladder content and residue
    • Espuela Orgaz R, Gomez AZ, Ramirez CT, Torres JLM. Application of bladder ultrasonography. Bladder content and residue. J Urol 1981;125:174-176.
    • (1981) J Urol , vol.125 , pp. 174-176
    • Espuela Orgaz, R.1    Gomez, A.Z.2    Ramirez, C.T.3    Torres, J.L.M.4
  • 20
    • 0018184517 scopus 로고
    • Determination of bladder volumes by gray scale ultrasound
    • McLean GK, Edell SL. Determination of bladder volumes by gray scale ultrasound. Radiology 1978;128:181-182.
    • (1978) Radiology , vol.128 , pp. 181-182
    • McLean, G.K.1    Edell, S.L.2
  • 21
    • 0022543249 scopus 로고
    • Accuracy and repeatability of bladder volume measurement using ultrasound imaging
    • Griffiths CJ, Murray A, Ramsden PD. Accuracy and repeatability of bladder volume measurement using ultrasound imaging. J Urol 1986;136:808-812.
    • (1986) J Urol , vol.136 , pp. 808-812
    • Griffiths, C.J.1    Murray, A.2    Ramsden, P.D.3
  • 23
    • 0014076793 scopus 로고
    • Ultrasonic studies of the bladder
    • Holmes JH. Ultrasonic studies of the bladder. J Urol 1967;97: 654-663.
    • (1967) J Urol , vol.97 , pp. 654-663
    • Holmes, J.H.1
  • 24
    • 0020699780 scopus 로고
    • The accuracy of a hand-held real-time ultrasound scanner for estimating bladder volume
    • Ravichandran G, Fellows GJ. The accuracy of a hand-held real-time ultrasound scanner for estimating bladder volume. Br J Urol 1983;55:25-27.
    • (1983) Br J Urol , vol.55 , pp. 25-27
    • Ravichandran, G.1    Fellows, G.J.2
  • 25
    • 0020536645 scopus 로고
    • The accuracy of ultrasound in the measurement of changes in bladder volume
    • Poston GJ, Joseph AEA, Riddle PR. The accuracy of ultrasound in the measurement of changes in bladder volume. Br J Urol 1983;55:361-363.
    • (1983) Br J Urol , vol.55 , pp. 361-363
    • Poston, G.J.1    Joseph, A.E.A.2    Riddle, P.R.3
  • 26
    • 0024423379 scopus 로고
    • Residual urine volumes in a normal female population: Application of transvaginal ultrasound
    • Haylen BT. Residual urine volumes in a normal female population: application of transvaginal ultrasound. Br J Urol 1989;64:347-349.
    • (1989) Br J Urol , vol.64 , pp. 347-349
    • Haylen, B.T.1
  • 27
    • 0024425983 scopus 로고
    • Verification of the accuracy and range of transvaginal ultrasound in measuring bladder volumes in women
    • Haylen BT. Verification of the accuracy and range of transvaginal ultrasound in measuring bladder volumes in women. Br J Urol 1989;64:350-352.
    • (1989) Br J Urol , vol.64 , pp. 350-352
    • Haylen, B.T.1
  • 28
    • 0023271846 scopus 로고
    • Real-time ultrasound measurement of bladder volume: A comparative study of three methods
    • Hartnell GG, Keily EA, Williams G, Gibson RN. Real-time ultrasound measurement of bladder volume: a comparative study of three methods. B J Radiol 1987;60:1063-1065.
    • (1987) B J Radiol , vol.60 , pp. 1063-1065
    • Hartnell, G.G.1    Keily, E.A.2    Williams, G.3    Gibson, R.N.4
  • 29
    • 0016831477 scopus 로고
    • Ultrasound assessment of residual urine in children
    • Harrison NW, Parks C, Sherwood T. Ultrasound assessment of residual urine in children. Br J Urol 1976;47:805-814.
    • (1976) Br J Urol , vol.47 , pp. 805-814
    • Harrison, N.W.1    Parks, C.2    Sherwood, T.3
  • 30
    • 0036202106 scopus 로고    scopus 로고
    • Detecting postoperative urinary retention with an ultrasound scanner
    • Rosseland LA, Stubhaug A, Breivik H. Detecting postoperative urinary retention with an ultrasound scanner. Acta Anaesthesiol Scand 2002;46:279-282.
    • (2002) Acta Anaesthesiol Scand , vol.46 , pp. 279-282
    • Rosseland, L.A.1    Stubhaug, A.2    Breivik, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.