-
1
-
-
0026581323
-
Biosensors for environmental monitoring
-
K. R. Rogers, and J. N. Lin, Biosensors for environmental monitoring. Biosens. Bioelectron., 7, 317-321 (1992).
-
(1992)
Biosens. Bioelectron.
, vol.7
, pp. 317-321
-
-
Rogers, K.R.1
Lin, J.N.2
-
2
-
-
0019024285
-
Ammonia electrode with immobilized nitrifying bacteria
-
M. Hikuma, T. Kubo, T. Yasuda, I. Karube, and S. Suzuki, Ammonia electrode with immobilized nitrifying bacteria. Anal. Chem., 52, 1020-1024 (1980).
-
(1980)
Anal. Chem.
, vol.52
, pp. 1020-1024
-
-
Hikuma, M.1
Kubo, T.2
Yasuda, T.3
Karube, I.4
Suzuki, S.5
-
3
-
-
0343469202
-
Ammonium ion sensor based on immobilized nitrifying bacteria and a cation exchange membrane
-
T. Okada, I. Karube, and S. Suzuki, Ammonium ion sensor based on immobilized nitrifying bacteria and a cation exchange membrane. Anal. Chim. Acta. 135, 159-65 (1982).
-
(1982)
Anal. Chim. Acta.
, vol.135
, pp. 159-165
-
-
Okada, T.1
Karube, I.2
Suzuki, S.3
-
4
-
-
0025275580
-
Amperometric determination of ammonium ions with a microbial sensor
-
K. Riedel, J. Huth, M. Kühn, and P. Liebs, Amperometric determination of ammonium ions with a microbial sensor. J. Chem. Technol. Biotechnol., 47, 109-116 (1990).
-
(1990)
J. Chem. Technol. Biotechnol.
, vol.47
, pp. 109-116
-
-
Riedel, K.1
Huth, J.2
Kühn, M.3
Liebs, P.4
-
5
-
-
0019632211
-
Amperometric determination of ammonia gas with immobilized nitrifying bacteria
-
I. Karube, T. Okada, and S. Suzuki, Amperometric determination of ammonia gas with immobilized nitrifying bacteria. Anal. Chem., 53, 1852-1855 (1981).
-
(1981)
Anal. Chem.
, vol.53
, pp. 1852-1855
-
-
Karube T Okada, I.1
Suzuki, S.2
-
6
-
-
0027786427
-
Development of the ammonia biosensor monitoring system
-
H. Tanaka, E. Nakamura, H. Hoshikawa, and Y. Tanaka, Development of the ammonia biosensor monitoring system. Water Sci. Technology 28, 435-445 (1993).
-
(1993)
Water Sci. Technology
, vol.28
, pp. 435-445
-
-
Tanaka, H.1
Nakamura, E.2
Hoshikawa, H.3
Tanaka, Y.4
-
7
-
-
0010614447
-
Artificial electron donors for nitrate and nitrite reductase usable as mediators in amperometric biosensors
-
B. Strehlitz, B. Gründig, K.-D. Vorlop, P. Bartholmes, H. Kotte, and U. Stottmeister, Artificial electron donors for nitrate and nitrite reductase usable as mediators in amperometric biosensors. Fresenius' J. Anal. Chem., 349, 676-678 (1994).
-
(1994)
Fresenius' J. Anal. Chem.
, vol.349
, pp. 676-678
-
-
Strehlitz, B.1
Gründig, B.2
Vorlop, K.-D.3
Bartholmes, P.4
Kotte, H.5
Stottmeister, U.6
-
8
-
-
0000747021
-
A nitrite sensor based on a highly sensitive nitrite reductase mediator-coupled amperometric detection
-
B. Strehlitz, B. Gründig, W. Schumacher, P. M. H. Kronach, and H. Kotte, A nitrite sensor based on a highly sensitive nitrite reductase mediator-coupled amperometric detection. Anal. Chem., 68, 807-816 (1996).
-
(1996)
Anal. Chem.
, vol.68
, pp. 807-816
-
-
Strehlitz, B.1
Gründig, B.2
Schumacher, W.3
Kronach, P.M.H.4
Kotte, H.5
-
9
-
-
0344934771
-
Bacterial membrane electrode for the determination of nitrate
-
R. K. Kobos, D. J. Rice, and D. S. Flournay, Bacterial membrane electrode for the determination of nitrate. Anal. Chem., 51, 1122-1125 (1979).
-
(1979)
Anal. Chem.
, vol.51
, pp. 1122-1125
-
-
Kobos R.K. Rice, D.J.1
Flournay, D.S.2
-
10
-
-
0016828220
-
A novel enzyme electrode method for the determination of nitrite based on nitrite reductase
-
H.-H. Kiang, S. S. Kuan, and G. G. Guilbault, A novel enzyme electrode method for the determination of nitrite based on nitrite reductase. Anal. Chim. Acta. 80, 209-214 (1975).
-
(1975)
Anal. Chim. Acta.
, vol.80
, pp. 209-214
-
-
Kiang, H.-H.1
Kuan, S.S.2
Guilbault, G.G.3
-
11
-
-
0019942474
-
Amperometric determination of sodium nitrite by a microbial sensor
-
I. Karube, T. Okada, S. Suzuki, H. Suzuki, M. Hikuma, and T. Yasuda, Amperometric determination of sodium nitrite by a microbial sensor. Eur. J. Appl. Microbiol. Biotechnol. 15, 127-132 (1982).
-
(1982)
Eur. J. Appl. Microbiol. Biotechnol.
, vol.15
, pp. 127-132
-
-
Karube, I.1
Okada, T.2
Suzuki, S.3
Suzuki, H.4
Hikuma, M.5
Yasuda, T.6
-
12
-
-
0020766824
-
2 sensor which uses immobilized nitrate oxidizing bacteria
-
2 sensor which uses immobilized nitrate oxidizing bacteria. Biotechnol. Bioeng., 25, 1641-1651 (1983).
-
(1983)
Biotechnol. Bioeng.
, vol.25
, pp. 1641-1651
-
-
Okada, T.1
Karube, I.2
Suzuki, S.3
-
13
-
-
0345869521
-
4-sensitive PVC-ISE
-
F. Scheller, and R. D. Schmid (eds.), GBF Monographs 17
-
4-sensitive PVC-ISE, in F. Scheller, and R. D. Schmid (eds.), Biosensors: Fundamentals, Technologies and Application, GBF Monographs 17, 1992, pp. 79-82.
-
(1992)
Biosensors: Fundamentals, Technologies and Application
, pp. 79-82
-
-
Butt, S.B.1
Krause, J.2
Cammann, K.3
-
14
-
-
0019981381
-
Hybrid urea sensor using nitrifying bacteria
-
T. Okada, I. Karube, and S. Suzuki, Hybrid urea sensor using nitrifying bacteria. Eur. J. Appl. Microbiol. Biotechnol., 14, 149-154 (1982).
-
(1982)
Eur. J. Appl. Microbiol. Biotechnol.
, vol.14
, pp. 149-154
-
-
Okada, T.1
Karube, I.2
Suzuki, S.3
-
15
-
-
0345869487
-
Contribution en dévelopment d'un nouveau modèle d'electrode: L'electrode bactrienne
-
B. J. Vincke, M. J. Devleeschouwer, and G. J. Patriarche, Contribution en dévelopment d'un nouveau modèle d'electrode: l'electrode bactrienne. Anal. Lett., 16, 673-684 (1983).
-
(1983)
Anal. Lett.
, vol.16
, pp. 673-684
-
-
Vincke, B.J.1
Devleeschouwer, M.J.2
Patriarche, G.J.3
-
16
-
-
0347761080
-
Preparation and comparison of Proteus vulgaris bacterial electrodes for the determination of urea and their application
-
G. S. Ihn, B. W. Kim, M. J. Sohn, and I. T. Kim, Preparation and comparison of Proteus vulgaris bacterial electrodes for the determination of urea and their application (in Korean). Taehan Hwahakhoe Chi, 32, 323-332 (1988); Chem. Abstr., 109, 107, 156 (1988).
-
(1988)
Taehan Hwahakhoe Chi
, vol.32
, pp. 323-332
-
-
Ihn, G.S.1
Kim, B.W.2
Sohn, M.J.3
Kim, I.T.4
-
17
-
-
0345869516
-
-
G. S. Ihn, B. W. Kim, M. J. Sohn, and I. T. Kim, Preparation and comparison of Proteus vulgaris bacterial electrodes for the determination of urea and their application (in Korean). Taehan Hwahakhoe Chi, 32, 323-332 (1988); Chem. Abstr., 109, 107, 156 (1988).
-
(1988)
Chem. Abstr.
, vol.109
, pp. 107
-
-
-
18
-
-
85011152774
-
Microbial sensors for L-aspartic acid and urea
-
T. Morimoto, Y. Nakagawa, M. Senuma, and T. Tosa, Microbial sensors for L-aspartic acid and urea (in Japanese). Bumseki Kagaku, 39, 735-739 (1990).
-
(1990)
Bumseki Kagaku
, vol.39
, pp. 735-739
-
-
Morimoto, T.1
Nakagawa, Y.2
Senuma, M.3
Tosa, T.4
-
19
-
-
0009813739
-
Determination of free sulfur dioxide in wine by using a biosensor based on a glass electrode
-
K. Nakamura, K. Saegusa, M. Kurosawa, and Y. Amano, Determination of free sulfur dioxide in wine by using a biosensor based on a glass electrode. Biosci. Biotechnol. Biochem. 57, 379-382 (1993).
-
(1993)
Biosci. Biotechnol. Biochem.
, vol.57
, pp. 379-382
-
-
Nakamura, K.1
Saegusa, K.2
Kurosawa, M.3
Amano, Y.4
-
20
-
-
0028278023
-
Microbial sensor for selective determination of sulphide
-
M. Kurosawa, T. Hiroano, K. Nakamura, and Y. Amano, Microbial sensor for selective determination of sulphide. Appl. Microbiol. Biotechnol., 41, 556-559 (1994).
-
(1994)
Appl. Microbiol. Biotechnol.
, vol.41
, pp. 556-559
-
-
Kurosawa, M.1
Hiroano, T.2
Nakamura, K.3
Amano, Y.4
-
21
-
-
0343312407
-
Amperometric determination of sulfite with sulfite oxidase immobilized at a platinum electrode surface
-
T. Fonong, Amperometric determination of sulfite with sulfite oxidase immobilized at a platinum electrode surface. Anal. Chim. Acta. 184, 287-290 (1986).
-
(1986)
Anal. Chim. Acta.
, vol.184
, pp. 287-290
-
-
Fonong, T.1
-
22
-
-
0009036161
-
Determination of sulfite by using microbial sensor
-
M. Suzuki, S. Lee, K. Fujil, Y. Arikawa, I. Kubo, T. Kanagawa, E. Mikami, and I. Karube, Determination of sulfite by using microbial sensor. Anal. Lett., 15, 973-982 (1992).
-
(1992)
Anal. Lett.
, vol.15
, pp. 973-982
-
-
Suzuki, M.1
Lee, S.2
Fujil, K.3
Arikawa, Y.4
Kubo, I.5
Kanagawa, T.6
Mikami, E.7
Karube, I.8
-
23
-
-
0006096515
-
Preliminary studies of a bacterial sulfate electrode
-
R. K. Kobos, Preliminary studies of a bacterial sulfate electrode. Anal. Lett., 19, 353-362 (1986).
-
(1986)
Anal. Lett.
, vol.19
, pp. 353-362
-
-
Kobos, R.K.1
-
24
-
-
0347130748
-
-
Methode für die einfache enzymatische Bestimmung von anorganischen Phosphat. DE Patent 422/7569 (1992)
-
A. Warsinke, and B. Gründig, Methode für die einfache enzymatische Bestimmung von anorganischen Phosphat. DE Patent 422/7569 (1992).
-
-
-
Warsinke, A.1
Gründig, B.2
-
25
-
-
0021478933
-
Photomicrobial sensors for selective determination of phosphate
-
T. Matsunaga, S. Suzuki, and R. Tomoda, Photomicrobial sensors for selective determination of phosphate. Enzyme Microb. Technol., 6, 355-357 (1984).
-
(1984)
Enzyme Microb. Technol.
, vol.6
, pp. 355-357
-
-
Matsunaga S Suzuki, T.1
Tomoda, R.2
-
26
-
-
0025106966
-
Membrane biosensor for the determination of iron (II,III) based on immobilized cells of Thiobacillus ferroxidans
-
M. Mandl, and L. Macholan, Membrane biosensor for the determination of iron (II,III) based on immobilized cells of Thiobacillus ferroxidans. Folia Microbiol., 35, 363-367 (1990).
-
(1990)
Folia Microbiol.
, vol.35
, pp. 363-367
-
-
Mandl, M.1
Macholan, L.2
-
27
-
-
0000915402
-
A. biosensor for ferric ion
-
J. M. Barrero, M. C. Moreno-Bondi, M. C. Pérez-Conde, and C. Cámara, A. biosensor for ferric ion. Talanta, 40, 1619-1623 (1993).
-
(1993)
Talanta
, vol.40
, pp. 1619-1623
-
-
Barrero, J.M.1
Moreno-Bondi, M.C.2
Pérez-Conde, M.C.3
Cámara, C.4
-
28
-
-
0347218606
-
Biosensors for detection of heavy metal ions
-
R. D. Schmid and F. Scheller (eds), GBF Monographs 13
-
R. Hilpert, M. H. Zenk, and F. Binder, Biosensors for detection of heavy metal ions, in R. D. Schmid and F. Scheller (eds), Biosensors: Application in Medicine, Environmental Protection and Process Control, GBF Monographs 13 1989, pp. 367-370.
-
(1989)
Biosensors: Application in Medicine, Environmental Protection and Process Control
, pp. 367-370
-
-
Hilpert, R.1
Zenk, M.H.2
Binder, F.3
-
29
-
-
0027594651
-
Amperometric biosensing of heavy metal ions using a hybrid type of apoenzyme membrane in flow streams
-
I. Satoh, Amperometric biosensing of heavy metal ions using a hybrid type of apoenzyme membrane in flow streams. Sens. Actuat. B, 13-14, 162-165 (1993).
-
(1993)
Sens. Actuat. B
, vol.13-14
, pp. 162-165
-
-
Satoh, I.1
-
30
-
-
0007721951
-
Development of biosensors to measure metal ion bioavailability in mining and metal wastes
-
A. E. Torma, M. L. Apel, and C. L. Brierley, (eds.), The Minerals, Metals & Materials Society
-
D. S. Holmes, S. K. Dubey, and S. Gangolli, Development of biosensors to measure metal ion bioavailability in mining and metal wastes, in A. E. Torma, M. L. Apel, and C. L. Brierley, (eds.), Biohydrometallurgical Technologies. The Minerals, Metals & Materials Society, 1993, pp. 659-666.
-
(1993)
Biohydrometallurgical Technologies
, pp. 659-666
-
-
Holmes, D.S.1
Dubey, S.K.2
Gangolli, S.3
-
31
-
-
0027411275
-
Direct determination of lead by bioaccumulation at a moss-modified carbon paste electrode
-
J. A. Ramos, E. Bermejo, A. Zapardiel, J. A. Perez, and L. Hernandez, Direct determination of lead by bioaccumulation at a moss-modified carbon paste electrode. Anal. Chim. Acta, 273, 219 (1993).
-
(1993)
Anal. Chim. Acta
, vol.273
, pp. 219
-
-
Ramos, J.A.1
Bermejo, E.2
Zapardiel, A.3
Perez, J.A.4
Hernandez, L.5
-
32
-
-
0026677974
-
Characterization of the effects of aluminum on luciferase biosensors for the detection of ecotoxicity
-
J. Guzzo, A. Guzzo, and M. S. DuBon, Characterization of the effects of aluminum on luciferase biosensors for the detection of ecotoxicity. Toxicol. Lett., 64-65, 687 (1992).
-
(1992)
Toxicol. Lett.
, vol.64-65
, pp. 687
-
-
Guzzo A Guzzo, J.1
DuBon, M.S.2
-
33
-
-
0029209486
-
Methylphenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols
-
H. Kotte, B. Gründig, K.-D. Vorlop, B. Strehlitz, and U. Stottmeister, Methylphenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols. Anal. Chem., 57, 65-70 (1995).
-
(1995)
Anal. Chem.
, vol.57
, pp. 65-70
-
-
Kotte, H.1
Gründig, B.2
Vorlop, K.-D.3
Strehlitz, B.4
Stottmeister, U.5
-
34
-
-
0027762011
-
Amperometric biosensor for the determination of phenolic compounds using a tyrosinase graphite electrode in a flow injection system
-
F. Ortega, E. Domínguez, G. Jönnson-Petterson, and L. Gorton, Amperometric biosensor for the determination of phenolic compounds using a tyrosinase graphite electrode in a flow injection system. J. Biochem., 31, 289-300 (1993).
-
(1993)
J. Biochem.
, vol.31
, pp. 289-300
-
-
Ortega, F.1
Domínguez, E.2
Jönnson-Petterson, G.3
Gorton, L.4
-
35
-
-
0027244240
-
A new strategy for the construction of a tyrosinase-based amperometric phenol and o-diphenol sensor
-
S. Cosnier, and C. Innocent, A new strategy for the construction of a tyrosinase-based amperometric phenol and o-diphenol sensor. Biochim. Bioenerget., 31, 147-160 (1993).
-
(1993)
Biochim. Bioenerget.
, vol.31
, pp. 147-160
-
-
Cosnier, S.1
Innocent, C.2
-
36
-
-
0025084882
-
A sensitive enzyme electrode for phenol monitoring
-
J. Kulys, and R. D. Schmid. A sensitive enzyme electrode for phenol monitoring. Anal. Lett., 23, 589 (1990).
-
(1990)
Anal. Lett.
, vol.23
, pp. 589
-
-
Kulys, J.1
Schmid, R.D.2
-
38
-
-
0028938083
-
Microbial sensors for determination of aromatics and their chloroderivates. Part III. Determination of chlorinated phenols using a biosensors containing Trichosporon beigelii (cutaneum)
-
K. Riedel, B. Beyersdorf-Radeck, B. Neumann, and F. Scheller, Microbial sensors for determination of aromatics and their chloroderivates. Part III. Determination of chlorinated phenols using a biosensors containing Trichosporon beigelii (cutaneum). Appl. Microbiol. Biotechnol. 43, 7-9 (1995).
-
(1995)
Appl. Microbiol. Biotechnol.
, vol.43
, pp. 7-9
-
-
Riedel, K.1
Beyersdorf-Radeck, B.2
Neumann, B.3
Scheller, F.4
-
39
-
-
0025987556
-
Biosensoren zur Bestimmung von Phenol und Benzoat auf der Basis von Rhodococcus-Zellen und Enzymextrakten
-
K. Riedel, J. Hensel, and K. Ebert, Biosensoren zur Bestimmung von Phenol und Benzoat auf der Basis von Rhodococcus-Zellen und Enzymextrakten, Zentralbl. Bakteriol., 146, 425-434 (1991).
-
(1991)
Zentralbl. Bakteriol.
, vol.146
, pp. 425-434
-
-
Riedel, K.1
Hensel, J.2
Ebert, K.3
-
40
-
-
84963178319
-
Biocatalytical membrane electrode for phenol
-
A. Ciucu, V. Magearu, S. Fleschin, L. Lucaciu, and F. David, Biocatalytical membrane electrode for phenol. Anal. Lett., 24, 567-580 (1991).
-
(1991)
Anal. Lett.
, vol.24
, pp. 567-580
-
-
Ciucu, A.1
Magearu, V.2
Fleschin, S.3
Lucaciu, L.4
David, F.5
-
41
-
-
0027394067
-
Microbial sensors for determination of aromatics and their chloroderivates. Part II. Determination of chlorinated phenols using a Rhodococcus containing biosensors
-
K. Riedel, J. Hensel, S. Rothe, B. Neumann, and F. Scheller, Microbial sensors for determination of aromatics and their chloroderivates. Part II. Determination of chlorinated phenols using a Rhodococcus containing biosensors. Appl. Microbiol. Biotechnol., 38, 556-559 (1993).
-
(1993)
Appl. Microbiol. Biotechnol.
, vol.38
, pp. 556-559
-
-
Riedel, K.1
Hensel, J.2
Rothe, S.3
Neumann, B.4
Scheller, F.5
-
42
-
-
0025859750
-
Microbial sensors for determination of aromatics and their chloroderivates. Part I. Determination of 3-chlorobenzoate using a Pseudomonas containing biosensors
-
K. Riedel, A. V. Naumov, L. A. Boronin, L. A. Golovleva, J. Stein, and F. Scheller, Microbial sensors for determination of aromatics and their chloroderivates. Part I. Determination of 3-chlorobenzoate using a Pseudomonas containing biosensors. Appl. Microbiol. Biotechnol., 35, 559-562 (1991).
-
(1991)
Appl. Microbiol. Biotechnol.
, vol.35
, pp. 559-562
-
-
Riedel, K.1
Naumov, A.V.2
Boronin, L.A.3
Golovleva, L.A.4
Stein, J.5
Scheller, F.6
-
43
-
-
3643137341
-
Development of microbial sensors for determination of xenobiotics
-
F. Scheller and R. D. Schmid (eds.), GBF Monographs 17
-
B. Beyersdorf-Radek, K. Riedel, B. Neumann, F. Scheller, and R. D. Schmid, Development of microbial sensors for determination of xenobiotics in F. Scheller and R. D. Schmid (eds.), Biosensors: Fundamentals, Technologies and Application, GBF Monographs 17, 1991, pp. 55-60.
-
(1991)
Biosensors: Fundamentals, Technologies and Application
, pp. 55-60
-
-
Beyersdorf-Radek, B.1
Riedel, K.2
Neumann, B.3
Scheller, F.4
Schmid, R.D.5
-
44
-
-
0347761079
-
Microbial sensors for the determination of aromatics and their chloroderivates
-
H. Verachten and W. F. Verstraete (eds.), Oostende, Belgium
-
B. Beyersdorf-Radek, R. D. Schmid, K. Riedel, B. Neumann, and F. Scheller, Microbial sensors for the determination of aromatics and their chloroderivates, in H. Verachten and W. F. Verstraete (eds.), Proc. Symposium on Environmental Biotechnology, Oostende, Belgium, 1991, pp. 65-68.
-
(1991)
Proc. Symposium on Environmental Biotechnology
, pp. 65-68
-
-
Beyersdorf-Radek, B.1
Schmid, R.D.2
Riedel, K.3
Neumann, B.4
Scheller, F.5
-
45
-
-
0028325474
-
An amperometric benzene sensor using whole cell Pseudomonas putida ML2
-
H.-M. Tan, S.-P. Cheong, and T.-C. Tan, An amperometric benzene sensor using whole cell Pseudomonas putida ML2. Biosens. Bioelectron., 9, 1-8 (1994).
-
(1994)
Biosens. Bioelectron.
, vol.9
, pp. 1-8
-
-
Tan S-P Cheong, H.-M.1
Tan, T.-C.2
-
46
-
-
0027591448
-
Luminescent biomonitoring of benzene derivates in the environment using recombinant Escherichia coli
-
Y. Ikariyama, S. Nishiguchi, E. Kobatake, M. Aizawa, M. Tsuda, and T. Nakazawa, Luminescent biomonitoring of benzene derivates in the environment using recombinant Escherichia coli. Sens. Actuat. B. 13-14, 169-172 (1993).
-
(1993)
Sens. Actuat. B
, vol.13-14
, pp. 169-172
-
-
Ikariyama, Y.1
Nishiguchi, S.2
Kobatake, E.3
Aizawa, M.4
Tsuda, M.5
Nakazawa, T.6
-
47
-
-
0028209314
-
Optical biosensor for environmental on-line monitoring of naphthaline and salicylate unavailability with an immobilized bioluminescent catabolic reporter bacterium
-
A. Heitzer, K. Malchowsky, J. E. Thonnard, P. R. Bienkowski, D. C. White, and G. S. Sayler, Optical biosensor for environmental on-line monitoring of naphthaline and salicylate unavailability with an immobilized bioluminescent catabolic reporter bacterium. Appl. Environment. Microbiol., 60, 1487-1494 (1994).
-
(1994)
Appl. Environment. Microbiol.
, vol.60
, pp. 1487-1494
-
-
Heitzer, A.1
Malchowsky, K.2
Thonnard, J.E.3
Bienkowski, P.R.4
White, D.C.5
Sayler, G.S.6
-
48
-
-
0029779897
-
Microbial sensors for naphthaline using Spingomonas sp. B1 or Pseudomonas fluorescens WW4
-
A. König, C. Zaborosch, A. Muscat, K. D. Vorlop, and F. Spener, Microbial sensors for naphthaline using Spingomonas sp. B1 or Pseudomonas fluorescens WW4. Appl. Microbiol. Biotechnol., 45, 844-850 (1996).
-
(1996)
Appl. Microbiol. Biotechnol.
, vol.45
, pp. 844-850
-
-
König, A.1
Zaborosch, C.2
Muscat, A.3
Vorlop, K.D.4
Spener, F.5
-
49
-
-
0019130171
-
A specific microbial sensor for formic acid
-
T. Matsunaga, I. Karube, and S. Suzuki, A specific microbial sensor for formic acid. Eur. J. Appl. Microbiol. Biotechnol., 10, 235-243 (1980).
-
(1980)
Eur. J. Appl. Microbiol. Biotechnol.
, vol.10
, pp. 235-243
-
-
Matsunaga, T.1
Karube, I.2
Suzuki, S.3
-
50
-
-
0019450180
-
Microbial sensor system which uses Methylomonas sp. for the determination of methane
-
T. Okada, I. Karube, and S. Suzuki, Microbial sensor system which uses Methylomonas sp. for the determination of methane. Eur. J. Appl. Microbiol. Biotechnol., 12, 102-106 (1981).
-
(1981)
Eur. J. Appl. Microbiol. Biotechnol.
, vol.12
, pp. 102-106
-
-
Okada, T.1
Karube, I.2
Suzuki, S.3
-
51
-
-
0027422676
-
A microbial biosensor system for dichloromethanes
-
T. Henrysson, and B. Mattiasson, A microbial biosensor system for dichloromethanes. Biodegradation, 4, 101-105 (1993).
-
(1993)
Biodegradation
, vol.4
, pp. 101-105
-
-
Henrysson, T.1
Mattiasson, B.2
-
52
-
-
0009812707
-
Application of microbial cells as multistep catalysts in potentiometric biosensing electrodes
-
R. K. Kobos, and H. Y. Pyon, Application of microbial cells as multistep catalysts in potentiometric biosensing electrodes. Biotechnol. Bioeng., 23, 627-634 (1981).
-
(1981)
Biotechnol. Bioeng.
, vol.23
, pp. 627-634
-
-
Kobos, R.K.1
Pyon, H.Y.2
-
53
-
-
0026837417
-
Use of a fibre optic immunosensor for the detection of pesticides
-
F. F. Bier, W. Stöcklein, M. Böcher, U. Bilitewski, and R. Schmid, Use of a fibre optic immunosensor for the detection of pesticides. Sens. Actuat. B, 7, 505-512 (1992).
-
(1992)
Sens. Actuat. B
, vol.7
, pp. 505-512
-
-
Bier, F.F.1
Stöcklein, W.2
Böcher, M.3
Bilitewski, U.4
Schmid, R.5
-
54
-
-
25044449739
-
Flow injection immunoanalysis (FIIA): A new format of immunoassay for the determination of pesticides in water
-
R. D. Schmid (ed.), GBF Monographs 17
-
P. Krämer and R. D. Schmid, Flow injection immunoanalysis (FIIA): a new format of immunoassay for the determination of pesticides in water, in R. D. Schmid (ed.), Flow Injection Analysis (FIA) Based on Enzymes or Antibiotics, GBF Monographs 17, 1991, 189-197.
-
(1991)
Flow Injection Analysis (FIA) Based on Enzymes or Antibiotics
, pp. 189-197
-
-
Krämer, P.1
Schmid, R.D.2
-
55
-
-
0023889285
-
Reaktivierbare Enzymelektrode mit Acetylcholinesterase zur differenzieren Erfassung von Insektiziden im Spurenbereich, Fresenius' Z
-
G. Schwedt, M. Hauck, Reaktivierbare Enzymelektrode mit Acetylcholinesterase zur differenzieren Erfassung von Insektiziden im Spurenbereich, Fresenius' Z. Anal. Chem., 331, 316-320 (1988).
-
(1988)
Anal. Chem.
, vol.331
, pp. 316-320
-
-
Schwedt M Hauck, G.1
-
56
-
-
0027448121
-
Comparison of immobilization for the development of an acetylcholinesterase biosensor
-
K. Stein, and G. Schwedt, Comparison of immobilization for the development of an acetylcholinesterase biosensor. Anal. Chim. Acta, 272, 73-81 (1993).
-
(1993)
Anal. Chim. Acta
, vol.272
, pp. 73-81
-
-
Stein, K.1
Schwedt, G.2
-
58
-
-
0000073032
-
Mediated herbicide inhibition in a PET biosensor
-
M. Preuss, and E. A. A. Hall, Mediated herbicide inhibition in a PET biosensor. Anal. Chem., 67, 1940-1949 (1995).
-
(1995)
Anal. Chem.
, vol.67
, pp. 1940-1949
-
-
Preuss, M.1
Hall, E.A.A.2
-
59
-
-
0343847699
-
Detection and quantification of triazine herbicides using algal cell fluorescence
-
L. H. Weston and P. K. Robinson, Detection and quantification of triazine herbicides using algal cell fluorescence. Biotechnol. Tech., 5, 327-330 (1991).
-
(1991)
Biotechnol. Tech.
, vol.5
, pp. 327-330
-
-
Weston, L.H.1
Robinson, P.K.2
-
60
-
-
0026570698
-
Sensitive biolumicescent detection of pesticides utilizing a membrane mutant of Escherichia coli and recombinant DNa technology
-
S. Lee, M. Suzuki, E. Tamiya, and I. Karube, Sensitive biolumicescent detection of pesticides utilizing a membrane mutant of Escherichia coli and recombinant DNA technology. Anal. Chim. Acta, 257, 183-188 (1992).
-
(1992)
Anal. Chim. Acta
, vol.257
, pp. 183-188
-
-
Lee, S.1
Suzuki, M.2
Tamiya, E.3
Karube, I.4
-
61
-
-
0017760504
-
Microbial electrode BOD sensor
-
I. Karube, T. Matsunaga, S. Mitsuda, and S. Suzuki, Microbial electrode BOD sensor. Biotechnol. Bioeng., 19, 1535-1547 (1977).
-
(1977)
Biotechnol. Bioeng.
, vol.19
, pp. 1535-1547
-
-
Karube, I.1
Matsunaga, T.2
Mitsuda, S.3
Suzuki, S.4
-
62
-
-
0000693193
-
A fast estimation of BOD with microbial sensors
-
K. Riedel, R. Renneberg, M. Kühn, and F. Scheller, A fast estimation of BOD with microbial sensors. Appl. Microbiol. Biotechnol., 28, 316-318 (1988).
-
(1988)
Appl. Microbiol. Biotechnol.
, vol.28
, pp. 316-318
-
-
Riedel, K.1
Renneberg, R.2
Kühn, M.3
Scheller, F.4
-
63
-
-
0019578441
-
Preliminary screening of mutagens with a microbial sensor
-
I. Karube, and S. Suzuki, Preliminary screening of mutagens with a microbial sensor. Anal. Chem., 53, 1024-1026 (1981).
-
(1981)
Anal. Chem.
, vol.53
, pp. 1024-1026
-
-
Karube, I.1
Suzuki, S.2
-
64
-
-
0021423502
-
Rapid BOD measurement for municipal waste water samples using a biofilm electrode
-
S. E. Strand, and D. A. Carlson, Rapid BOD measurement for municipal waste water samples using a biofilm electrode. J. Water Pollut. Control Fed., 56, 464-467 (1984).
-
(1984)
J. Water Pollut. Control Fed.
, vol.56
, pp. 464-467
-
-
Strand, S.E.1
Carlson, D.A.2
-
65
-
-
0018635290
-
Amperometric estimation of BOD by using living immobilized yeasts
-
M. Hikuma, H. Suzuki, T. Yasuda, I. Karube, and S. Suzuki, Amperometric estimation of BOD by using living immobilized yeasts. Eur. J. Appl. Microbiol. Biotechnol., 8, 289-297 (1979).
-
(1979)
Eur. J. Appl. Microbiol. Biotechnol.
, vol.8
, pp. 289-297
-
-
Hikuma, M.1
Suzuki, H.2
Yasuda, T.3
Karube, I.4
Suzuki, S.5
-
66
-
-
0000443148
-
BOD quick estimating system utilizing a microbial electrode
-
R. A. C. Drake (ed.), Transport Systems, Proc. IAWPRC Workshop
-
K. Harita, Y. Otani, M. Hikuma, and T. Yasuda, BOD quick estimating system utilizing a microbial electrode, in R. A. C. Drake (ed.), Instrumental Control of Water and Wastewater Treatment, Transport Systems, Proc. IAWPRC Workshop, 1985, pp. 529-532.
-
(1985)
Instrumental Control of Water and Wastewater Treatment
, pp. 529-532
-
-
Harita, K.1
Otani, Y.2
Hikuma, M.3
Yasuda, T.4
-
67
-
-
0347761072
-
BOD estimation system using immobilized yeast cells
-
K. C. Chen, and T. T. Hwang, BOD estimation system using immobilized yeast cells (in Chinese). Chung-kuo Nung Yeh Hua Hueh Hui Chih, 25, 369-377 (1987); Chem. Abstr., 108, 192237 (1988).
-
(1987)
Chung-kuo Nung Yeh Hua Hueh Hui Chih
, vol.25
, pp. 369-377
-
-
Chen, K.C.1
Hwang, T.T.2
-
68
-
-
0347130754
-
-
K. C. Chen, and T. T. Hwang, BOD estimation system using immobilized yeast cells (in Chinese). Chung-kuo Nung Yeh Hua Hueh Hui Chih, 25, 369-377 (1987); Chem. Abstr., 108, 192237 (1988).
-
(1988)
Chem. Abstr.
, vol.108
, pp. 192237
-
-
-
69
-
-
0025455689
-
A microbial sensor for BOD
-
K. Riedel, K.-P. Lange, H. J. Stein, M. Kühn, P. Ott, and F. Scheller, A microbial sensor for BOD. Water Res., 24, 883-887 (1990).
-
(1990)
Water Res.
, vol.24
, pp. 883-887
-
-
Riedel, K.1
Lange, K.-P.2
Stein, H.J.3
Kühn, M.4
Ott, P.5
Scheller, F.6
-
70
-
-
12044258118
-
Optical fiber sensor for biological oxygen demand
-
C. Preininger, I. Klimant, and O. S. Wolfbeis, Optical fiber sensor for biological oxygen demand. Anal. Chem. 66, 1841-1846 (1994).
-
(1994)
Anal. Chem.
, vol.66
, pp. 1841-1846
-
-
Preininger, C.1
Klimant, I.2
Wolfbeis, O.S.3
-
72
-
-
0026128647
-
Study of BOD microbial sensors for waste water treatment control
-
Y. R. Li, and J. Chu, Study of BOD microbial sensors for waste water treatment control. Appl. Biochem. Biotechnol., 28, 855-863 (1991).
-
(1991)
Appl. Biochem. Biotechnol.
, vol.28
, pp. 855-863
-
-
Li, Y.R.1
Chu, J.2
-
73
-
-
0003347166
-
Microbial sensor of biochemical oxygen demand using Hansenula anomala
-
G. S. Ihn, K. H. Park, U. H. Pek, and Moo Jeong, Microbial sensor of biochemical oxygen demand using Hansenula anomala. Bull. Korean Chem. Soc., 13, 145-148 (1992).
-
(1992)
Bull. Korean Chem. Soc.
, vol.13
, pp. 145-148
-
-
Ihn, G.S.1
Park, K.H.2
Pek, U.H.3
Jeong, M.4
-
74
-
-
21344479232
-
Comprehension of the response time in a microbial BOD sensor (II)
-
M.-J. Sohn, and D. Hong, Comprehension of the response time in a microbial BOD sensor (II). Bull. Korean Chem. Soc., 14, 666-668 (1993).
-
(1993)
Bull. Korean Chem. Soc.
, vol.14
, pp. 666-668
-
-
Sohn, M.-J.1
Hong, D.2
-
75
-
-
0041488109
-
Biosensor for the estimation of biological oxygen demand based on Torulopsis candida
-
S. Rajasekar, V. M. Madhav, R. Rajasekar, D. Jeyakumar, and G. P. Rao, Biosensor for the estimation of biological oxygen demand based on Torulopsis candida. Bull. Electrochem., 8, 196-198 (1992).
-
(1992)
Bull. Electrochem.
, vol.8
, pp. 196-198
-
-
Rajasekar, S.1
Madhav, V.M.2
Rajasekar, R.3
Jeyakumar, D.4
Rao, G.P.5
-
76
-
-
0022698483
-
A new biosensor for rapid BOD estimation by using immobilized growing cell beads
-
Y. C. Su, J. H. Huang, and M. L. Liu, A new biosensor for rapid BOD estimation by using immobilized growing cell beads. Proc. Natl. Sci. Counc. B. ROC, 10, 105-112 (1986).
-
(1986)
Proc. Natl. Sci. Counc. B. ROC
, vol.10
, pp. 105-112
-
-
Su, Y.C.1
Huang, J.H.2
Liu, M.L.3
-
77
-
-
0026867650
-
Microbial membrane-modified dissolved oxygen probe for rapid biochemical oxygen demand measurement
-
T. C. Tan, F. Li, K. G. Neoh, and Y. K. Lee, Microbial membrane-modified dissolved oxygen probe for rapid biochemical oxygen demand measurement. Sens. Actuat. B, 8, 167-172 (1992).
-
(1992)
Sens. Actuat. B
, vol.8
, pp. 167-172
-
-
Tan, T.C.1
Li, F.2
Neoh, K.G.3
Lee, Y.K.4
-
78
-
-
0010615941
-
Microbial sensor for the BOD estimation
-
X. Zhang, Z. Wang, and H. Jian, Microbial sensor for the BOD estimation (in Chinese). Huanjing Kexue Xuebao, 6, 184-192 (1986); Chem. Abstr., 105, 158286 (1986).
-
(1986)
Huanjing Kexue Xuebao
, vol.6
, pp. 184-192
-
-
Zhang, X.1
Wang, Z.2
Jian, H.3
-
79
-
-
84988126378
-
-
X. Zhang, Z. Wang, and H. Jian, Microbial sensor for the BOD estimation (in Chinese). Huanjing Kexue Xuebao, 6, 184-192 (1986); Chem. Abstr., 105, 158286 (1986).
-
(1986)
Chem. Abstr.
, vol.105
, pp. 158286
-
-
-
80
-
-
85007934552
-
Biological oxygen demand sensor using an arsenic resistant bacterium
-
A. Ohki, K. Shinohara, and S. Maeda, Biological oxygen demand sensor using an arsenic resistant bacterium. Anal. Sci., 6, 905-906 (1990).
-
(1990)
Anal. Sci.
, vol.6
, pp. 905-906
-
-
Ohki, A.1
Shinohara, K.2
Maeda, S.3
-
81
-
-
0024374797
-
Microbial BOD sensor utilizing thermophilic bacteria
-
I. Karube, K. Yokoyama, K. Sode, and E. Tamiya, Microbial BOD sensor utilizing thermophilic bacteria. Anal. Lett., 22, 791-801 (1989).
-
(1989)
Anal. Lett.
, vol.22
, pp. 791-801
-
-
Karube, I.1
Yokoyama, K.2
Sode, K.3
Tamiya, E.4
-
82
-
-
0010618760
-
Microbial sensor for rapid estimation of biochemical oxygen demand (BOD) in presence of heavy metal ions
-
R.-D. Wilken, U. Förster, and A. Krodël (eds.), CER Consultants Ltd., Edingburgh, Scotland
-
M. Slama, Ch. Zaborosch, and F. Spener, Microbial sensor for rapid estimation of biochemical oxygen demand (BOD) in presence of heavy metal ions, in R.-D. Wilken, U. Förster, and A. Krodël (eds.), International Conference on Heavy Metals in the Environment. CER Consultants Ltd., Edingburgh, Scotland, 1995, Vol. 2, pp. 171-174.
-
(1995)
International Conference on Heavy Metals in the Environment
, vol.2
, pp. 171-174
-
-
Slama, M.1
Zaborosch, Ch.2
Spener, F.3
-
83
-
-
0028604590
-
BOD biosensor for secondary effluent from wastewater treatment plants
-
H. Tanaka, E. Nakamura, Y. Minamiyama, and T. Toyoda, BOD biosensor for secondary effluent from wastewater treatment plants. Water Sci. Technol., 30, 215-227 (1994).
-
(1994)
Water Sci. Technol.
, vol.30
, pp. 215-227
-
-
Tanaka, H.1
Nakamura, E.2
Minamiyama, Y.3
Toyoda, T.4
-
84
-
-
0007627771
-
Minutenschnelle Bestimmung des BSB
-
K. Riedel, R. Kloos, R. Uthemann, Minutenschnelle Bestimmung des BSB, Wasser Boden Luft, 11-12, 35-38 (1993).
-
(1993)
Wasser Boden Luft
, vol.11-12
, pp. 35-38
-
-
Riedel, K.1
Kloos, R.2
Uthemann, R.3
-
85
-
-
0038726698
-
Sensor BSB: Ein neuer mit Biosensoren gewonnener Summenparameter in der Abwasseranalytik
-
K. Riedel, R. Uthemann, Sensor BSB: ein neuer mit Biosensoren gewonnener Summenparameter in der Abwasseranalytik, Wasserwirtsch. Wassertech., 2, 35-38 (1994).
-
(1994)
Wasserwirtsch. Wassertech.
, vol.2
, pp. 35-38
-
-
Riedel R Uthemann, K.1
-
86
-
-
0347130753
-
Determination of BOD in waste water with a commercial combination-sensor containing Rhodococcus erythropolis and Issatchenkia orientalis
-
in press
-
K. Riedel, R. Uthemann, X. Yang, and R. Renneberg, Determination of BOD in waste water with a commercial combination-sensor containing Rhodococcus erythropolis and Issatchenkia orientalis. Biosens. Bioelectron. (in press).
-
Biosens. Bioelectron.
-
-
Riedel, K.1
Uthemann, R.2
Yang, X.3
Renneberg, R.4
-
87
-
-
51249164304
-
Characterization of microbial membranes used for the estimation of biochemical oxygen demand with a biosensor
-
E. Galindo, J. L. Garcia, L. G. Torres, and R. Quintero, Characterization of microbial membranes used for the estimation of biochemical oxygen demand with a biosensor. Biotchnol. Tech., 6, 399-404 (1992).
-
(1992)
Biotchnol. Tech.
, vol.6
, pp. 399-404
-
-
Galindo, E.1
Garcia, J.L.2
Torres, L.G.3
Quintero, R.4
-
88
-
-
0347761074
-
-
Mikrobiologisches Sensorsystem zur Bestimmung des "Biochemischen Sauerstoffbedarfs" (BSB) von komplex zusammengesetzten, höhermolekularen Verbindungen enthaltenden Medien, DD Patent 275 379 A3 (1990)
-
K. Riedel, R. Renneberg, P. Ott, F. Scheller, J. Stein, E. Ritter, N. Fahrenbruch, and B. Klimes, Mikrobiologisches Sensorsystem zur Bestimmung des "Biochemischen Sauerstoffbedarfs" (BSB) von komplex zusammengesetzten, höhermolekularen Verbindungen enthaltenden Medien, DD Patent 275 379 A3 (1990).
-
-
-
Riedel, K.1
Renneberg, R.2
Ott, P.3
Scheller, F.4
Stein, J.5
Ritter, E.6
Fahrenbruch, N.7
Klimes, B.8
-
89
-
-
84885413880
-
BOD biosensor based on an amperometric oxygen electrode covered by Lipomyces kononenkoae
-
M. Reiss, A. Tari, and W. Hartmeier, BOD biosensor based on an amperometric oxygen electrode covered by Lipomyces kononenkoae. Bioengineering, 99, 87 (1993).
-
(1993)
Bioengineering
, vol.99
, pp. 87
-
-
Reiss, M.1
Tari, A.2
Hartmeier, W.3
-
90
-
-
0027604719
-
A novel BOD sensor based on bacterial luminescence
-
C.-K. Hyan, E. Tamiya, T. Takeuchi, and I. Karube, A novel BOD sensor based on bacterial luminescence. Biotechnol. Bioeng., 41, 1107-1111 (1993).
-
(1993)
Biotechnol. Bioeng.
, vol.41
, pp. 1107-1111
-
-
Hyan, C.-K.1
Tamiya, E.2
Takeuchi, T.3
Karube, I.4
-
91
-
-
0344262865
-
Trends in bioelectronics research
-
July-September
-
I. Karube, Trends in bioelectronics research. Sci. Technol. Japan, July-September, 1986, pp. 32-40.
-
(1986)
Sci. Technol. Japan
, pp. 32-40
-
-
Karube, I.1
-
92
-
-
0344933444
-
-
CRC Press, Boca Raton, Fla.
-
R. G. Bond, and C. P. Straub, Handbook of Environmental Control, Vol. 3. CRC Press, Boca Raton, Fla., 1973, pp. 671-686.
-
(1973)
Handbook of Environmental Control
, vol.3
, pp. 671-686
-
-
Bond, R.G.1
Straub, C.P.2
-
96
-
-
0038726700
-
Feldgerät mit Biosensor zur BSB-Kurzzeitmessung in Abwasser-reinigungsanlagen
-
H. Merten, Feldgerät mit Biosensor zur BSB-Kurzzeitmessung in Abwasser-reinigungsanlagen, Proc. Symposium der Technischen Akademie Esslingen, 1992.
-
(1992)
Proc. Symposium der Technischen Akademie Esslingen
-
-
Merten, H.1
-
98
-
-
0038388490
-
BSB-Kurzzeit-Messung mit Biosensoren in kommunalen Klärwerken
-
H. Merten, and S. Gehring, BSB-Kurzzeit-Messung mit Biosensoren in kommunalen Klärwerken, Wasserwirtsch. Wassertech., 3, 2-6 (1995).
-
(1995)
Wasserwirtsch. Wassertech.
, vol.3
, pp. 2-6
-
-
Merten, H.1
Gehring, S.2
-
99
-
-
0038388493
-
-
Prüfgerätewerk Medingen GmbH, Dresden
-
BSB-Modul (company literature), Prüfgerätewerk Medingen GmbH, Dresden.
-
BSB-Modul (Company Literature)
-
-
-
100
-
-
0028269021
-
Rapid BOD measurement with the Medingen BOD-module
-
R. Szweda, and R. Renneberg, Rapid BOD measurement with the Medingen BOD-module. Biosens. Bioelectron., 9, ix-x (1994).
-
(1994)
Biosens. Bioelectron.
, vol.9
-
-
Szweda, R.1
Renneberg, R.2
-
101
-
-
0347761077
-
Meßsystem für die Abwasserkontrolle
-
E. Klinger, and H. Merten, Meßsystem für die Abwasserkontrolle, Mikroelektronik, 6, (1992).
-
(1992)
Mikroelektronik
, vol.6
-
-
Klinger, E.1
Merten, H.2
-
105
-
-
84909888535
-
A microbial sensor for BOD
-
F. Scheller and R. D. Schmid (eds.), GBF Monographs 17
-
K. Riedel, B. Neumann, N. Klimes, B. Fahrenbruch, F. Scheller, H. Merten, E. Klinger and H.-J. Stein, A microbial sensor for BOD, in F. Scheller and R. D. Schmid (eds.), Biosensors: Fundamentals, Technologies and Application, GBF Monographs 17, 1991, pp. 51-54.
-
(1991)
Biosensors: Fundamentals, Technologies and Application
, pp. 51-54
-
-
Riedel, K.1
Neumann, B.2
Klimes, N.3
Fahrenbruch, B.4
Scheller, F.5
Merten, H.6
Klinger, E.7
Stein, H.-J.8
-
107
-
-
0028410815
-
An on-line respirographic biosensor for the characterization of load and toxicity of wastewaters
-
P. A. Vanrolleghem, Z. Kong, G. Rombputs, and W. Verstraete, An on-line respirographic biosensor for the characterization of load and toxicity of wastewaters. J. Chem. Biotechnol., 59, 321-333 (1994).
-
(1994)
J. Chem. Biotechnol.
, vol.59
, pp. 321-333
-
-
Vanrolleghem, P.A.1
Kong, Z.2
Rombputs, G.3
Verstraete, W.4
-
109
-
-
0028059826
-
Monitoring BOD in the presence of heavy metal ions by a poly(4-vinylpyridine) coated microbial sensor
-
F. Li, and T. C. Tan, Monitoring BOD in the presence of heavy metal ions by a poly(4-vinylpyridine) coated microbial sensor. Biosens. Bioelectron., 9, 445-455 (1994).
-
(1994)
Biosens. Bioelectron.
, vol.9
, pp. 445-455
-
-
Li, F.1
Tan, T.C.2
|