A technique for the measurement of patellar tracking during weight-bearing activities using ultrasound

Author keywords

Kinematics; Patella; Patellar tracking; Patello femoral joint; Ultrasound

Indexed keywords

JOINTS (ANATOMY); KINEMATICS; MAGNETIC RESONANCE IMAGING; PHYSIOLOGY; ULTRASONIC MEASUREMENT; MAGNETIC RESONANCE; ULTRASONIC APPLICATIONS; ULTRASONIC WAVES; ULTRASONICS;

EID: 0348146388     PISSN: 09544119     EISSN: None     Source Type: Journal    
DOI: 10.1243/09544110360729081     Document Type: Article
Times cited : (13)

References (30)
  • 1
    • 0033118556 scopus 로고    scopus 로고
    • In vitro measurement of the tracking pattern of the human patella
    • Ahmed, A. M., Duncan, N. A. and Tanzer, M. In vitro measurement of the tracking pattern of the human patella. Trans. ASME, J. Biomech. Engng, 1999, 121, 222-228.
    • (1999) Trans. ASME, J. Biomech. Engng , vol.121 , pp. 222-228
    • Ahmed, A.M.1    Duncan, N.A.2    Tanzer, M.3
  • 2
    • 0028898337 scopus 로고
    • A cadaver study of the function of the oblique part of vastus medialis
    • Goh, J. C., Lee, P. Y. and Bose, K. A cadaver study of the function of the oblique part of vastus medialis. J. Bone Jt Surg., 1995, 77-B, 225-231.
    • (1995) J. Bone Jt Surg. , vol.77 B , pp. 225-231
    • Goh, J.C.1    Lee, P.Y.2    Bose, K.3
  • 4
    • 0031044965 scopus 로고    scopus 로고
    • Influence of lateral release on patellar tracking and patellofemoral contact characteristics after total knee arthroplasty
    • Hsu, H. C., Luo, Z. P., Rand, J. A. and An, K. N. Influence of lateral release on patellar tracking and patellofemoral contact characteristics after total knee arthroplasty. J. Arthroplasty, 1997, 12, 74-83.
    • (1997) J. Arthroplasty , vol.12 , pp. 74-83
    • Hsu, H.C.1    Luo, Z.P.2    Rand, J.A.3    An, K.N.4
  • 7
    • 0038408944 scopus 로고    scopus 로고
    • Quadriceps forces and patellar motion in the anatomical model of the patellofemoral joint
    • Sakai, N., Luo, Z. P., Rand, J. A. and An, K. N. Quadriceps forces and patellar motion in the anatomical model of the patellofemoral joint. Knee, 1996, 3, 1-7.
    • (1996) Knee , vol.3 , pp. 1-7
    • Sakai, N.1    Luo, Z.P.2    Rand, J.A.3    An, K.N.4
  • 8
    • 0025426762 scopus 로고
    • The three-dimensional tracking pattern of the human patella
    • Van Kampen, A. and Huiskes, R. The three-dimensional tracking pattern of the human patella. J. Orthop. Res., 1990, 8, 372-382.
    • (1990) J. Orthop. Res. , vol.8 , pp. 372-382
    • Van Kampen, A.1    Huiskes, R.2
  • 11
    • 0004101501 scopus 로고
    • The use of intra-cortical pins to measure the motion of the knee joint during walking
    • PhD thesis, Pennsylvania State University
    • Lafortune, M. A. The use of intra-cortical pins to measure the motion of the knee joint during walking. PhD thesis, Pennsylvania State University, 1984.
    • (1984)
    • Lafortune, M.A.1
  • 13
    • 0027513704 scopus 로고
    • Patellar tracking patterns during active and passive knee extension: Evaluation with motion-triggered cine MR imaging
    • Brossmann, J., Muhle, C., Schroder, C., Melchert, U. H., Bull, C. C., Spielmann, R. P. and Heller, M. Patellar tracking patterns during active and passive knee extension: evaluation with motion-triggered cine MR imaging. Radiology, 1993, 187, 205-212.
    • (1993) Radiology , vol.187 , pp. 205-212
    • Brossmann, J.1    Muhle, C.2    Schroder, C.3    Melchert, U.H.4    Bull, C.C.5    Spielmann, R.P.6    Heller, M.7
  • 16
  • 17
    • 0027313206 scopus 로고
    • Patellofemoral joint: Identification of abnormalities with active-movement, 'unloaded' versus 'loaded' kinematic MR imaging techniques
    • Shellock, F. G., Mink, J. H., Deutsch, A. L., Foo, T. K. and Sullenberger, P. Patellofemoral joint: identification of abnormalities with active-movement, 'unloaded' versus 'loaded' kinematic MR imaging techniques. Radiology, 1993, 188, 575-578.
    • (1993) Radiology , vol.188 , pp. 575-578
    • Shellock, F.G.1    Mink, J.H.2    Deutsch, A.L.3    Foo, T.K.4    Sullenberger, P.5
  • 18
    • 0033406399 scopus 로고    scopus 로고
    • In vivo tracking of the human patella using cine phase contrast magnetic resonance imaging
    • Sheehan, F. T., Zajac, F. E. and Drace, J. E. In vivo tracking of the human patella using cine phase contrast magnetic resonance imaging. Trans. ASME, J. Biomech. Engng, 1999, 121, 650-656.
    • (1999) Trans. ASME, J. Biomech. Engng , vol.121 , pp. 650-656
    • Sheehan, F.T.1    Zajac, F.E.2    Drace, J.E.3
  • 19
    • 0035345266 scopus 로고    scopus 로고
    • Patello-femoral tracking in the weight-bearing knee: A study of asymptomatic volunteers utilising dynamic magnetic resonance imaging: A preliminary report
    • Tennant, S., Williams, A., Vedi, V., Kinmont, C., Gedroyc, W. and Hunt, D. M. Patello-femoral tracking in the weight-bearing knee: a study of asymptomatic volunteers utilising dynamic magnetic resonance imaging: a preliminary report. Knee Surg. Sports Traumatology Arthroscopy, 2001, 9, 155-162.
    • (2001) Knee Surg. Sports Traumatology Arthroscopy , vol.9 , pp. 155-162
    • Tennant, S.1    Williams, A.2    Vedi, V.3    Kinmont, C.4    Gedroyc, W.5    Hunt, D.M.6
  • 22
    • 0027171443 scopus 로고
    • The quantitative measurement of normal passive medial and lateral patellar motion limits
    • Skalley, T. C., Terry, G. C. and Teitge, R. A. The quantitative measurement of normal passive medial and lateral patellar motion limits. Am. J. Sports Medicine, 1993, 21, 728-732.
    • (1993) Am. J. Sports Medicine , vol.21 , pp. 728-732
    • Skalley, T.C.1    Terry, G.C.2    Teitge, R.A.3
  • 23
    • 0028857490 scopus 로고
    • Reliability of measurements obtained with four tests for patellofemoral alignment
    • Fitzgerald, G. K. and McClure, P. W. Reliability of measurements obtained with four tests for patellofemoral alignment. Phys. Ther., 1995, 75, 84-90.
    • (1995) Phys. Ther. , vol.75 , pp. 84-90
    • Fitzgerald, G.K.1    McClure, P.W.2
  • 24
    • 0018694826 scopus 로고
    • Patellar tracking patterns measurement by analytical x-ray photogrammetry
    • Veress, S. A., Lippert, F. G., Hou, M. C. and Takamoto, T. Patellar tracking patterns measurement by analytical x-ray photogrammetry. J. Biomechanics, 1979, 12, 639-650.
    • (1979) J. Biomechanics , vol.12 , pp. 639-650
    • Veress, S.A.1    Lippert, F.G.2    Hou, M.C.3    Takamoto, T.4
  • 27
    • 0026625238 scopus 로고
    • Effects of tibial rotations on patellar tracking and patello-femoral contact areas
    • Hefzy, M. S., Jackson, W. T., Saddemi, S. R. and Hsieh, Y. F. Effects of tibial rotations on patellar tracking and patello-femoral contact areas. J. Biomed. Engng, 1992, 14, 329-343.
    • (1992) J. Biomed. Engng , vol.14 , pp. 329-343
    • Hefzy, M.S.1    Jackson, W.T.2    Saddemi, S.R.3    Hsieh, Y.F.4
  • 28
    • 0034049967 scopus 로고    scopus 로고
    • The effect of reconstruction of the medial patellofemoral ligament on patellar tracking
    • Sandmeier, R. H., Burks, R. T., Bachus, K. N. and Billings, A. The effect of reconstruction of the medial patellofemoral ligament on patellar tracking. Am. J. Sports Medicine, 2000, 28, 345-349.
    • (2000) Am. J. Sports Medicine , vol.28 , pp. 345-349
    • Sandmeier, R.H.1    Burks, R.T.2    Bachus, K.N.3    Billings, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.