메뉴 건너뛰기




Volumn 13, Issue 6, 2003, Pages 377-380

A Comparison of Laparoscopic Bipolar Vessel Sealing Devices in the Hemostasis of Small-, Medium-, and Large-Sized Arteries

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ARTERY DIAMETER; ARTERY INJURY; ARTICLE; DEVICE; HEMOSTASIS; INTERMETHOD COMPARISON; LAPAROSCOPE; NONHUMAN; PRESSURE MEASUREMENT; PRIORITY JOURNAL; SURGICAL EQUIPMENT; SWINE; THERMAL INJURY; TRANSDUCER;

EID: 0348141829     PISSN: 10926429     EISSN: None     Source Type: Journal    
DOI: 10.1089/109264203322656441     Document Type: Article
Times cited : (128)

References (8)
  • 1
    • 0037306077 scopus 로고    scopus 로고
    • Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model
    • Landman J, Kerbl K, Rehman J, et al. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 2003;169:697-700.
    • (2003) J Urol , vol.169 , pp. 697-700
    • Landman, J.1    Kerbl, K.2    Rehman, J.3
  • 3
    • 0041357211 scopus 로고    scopus 로고
    • Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries
    • Epub ahead of Print
    • Harold KL, Pollinger HS, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 2003; 13:[Epub ahead of Print].
    • (2003) Surg Endosc , vol.13
    • Harold, K.L.1    Pollinger, H.S.2    Matthews, B.D.3    Kercher, K.W.4    Sing, R.F.5    Heniford, B.T.6
  • 5
    • 0036160006 scopus 로고    scopus 로고
    • The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery
    • Siperstein AE, Berber E, Morkoyun E. The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery. Arch Surg 2002;137:137-142.
    • (2002) Arch Surg , vol.137 , pp. 137-142
    • Siperstein, A.E.1    Berber, E.2    Morkoyun, E.3
  • 7
    • 0041527489 scopus 로고    scopus 로고
    • Electrocautery, argon beam coagulation, cryotherapy, and other hemostatic and tissue ablative instruments
    • Nyhus LM, Baker RJ, Fischer JE, (eds.). Boston: Little, Brown and Company
    • Hurst RD, Fichera A, Michelassi F. Electrocautery, argon beam coagulation, cryotherapy, and other hemostatic and tissue ablative instruments. In Nyhus LM, Baker RJ, Fischer JE, (eds.): Mastery of Surgery, Vol. I. Boston: Little, Brown and Company, 1997, pp. 234-245.
    • (1997) Mastery of Surgery , vol.1 , pp. 234-245
    • Hurst, R.D.1    Fichera, A.2    Michelassi, F.3
  • 8
    • 85039588305 scopus 로고    scopus 로고
    • Gyrus Medical PlasmaKinetic generator. Available at: http://www.gyrusmedical.com/products-plasmakinetics. asp?action=productview& ProductID=74. Accessed September 24, 2003.
    • Gyrus Medical PlasmaKinetic Generator


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.