1
-
-
0037306077
-
Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model
-
Landman J, Kerbl K, Rehman J, et al. Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 2003;169:697-700.
-
(2003)
J Urol
, vol.169
, pp. 697-700
-
-
Landman, J.1
Kerbl, K.2
Rehman, J.3
-
2
-
-
0032094281
-
High-burst-strength, feedback-controlled bipolar vessel sealing
-
Kennedy JS, Stranahan PL, Taylor KD, Chandler JG. High-burst-strength, feedback-controlled bipolar vessel sealing. Surg Endosc 1998;12:876-878.
-
(1998)
Surg Endosc
, vol.12
, pp. 876-878
-
-
Kennedy, J.S.1
Stranahan, P.L.2
Taylor, K.D.3
Chandler, J.G.4
-
3
-
-
0041357211
-
Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries
-
Epub ahead of Print
-
Harold KL, Pollinger HS, Matthews BD, Kercher KW, Sing RF, Heniford BT. Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 2003; 13:[Epub ahead of Print].
-
(2003)
Surg Endosc
, vol.13
-
-
Harold, K.L.1
Pollinger, H.S.2
Matthews, B.D.3
Kercher, K.W.4
Sing, R.F.5
Heniford, B.T.6
-
4
-
-
0034915528
-
Initial results with an electrothermal bipolar vessel sealer
-
Heniford BT, Matthews BD, Sing RF, Backus C, Pratt B, Greene FL. Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 2001;15:799-801.
-
(2001)
Surg Endosc
, vol.15
, pp. 799-801
-
-
Heniford, B.T.1
Matthews, B.D.2
Sing, R.F.3
Backus, C.4
Pratt, B.5
Greene, F.L.6
-
5
-
-
0036160006
-
The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery
-
Siperstein AE, Berber E, Morkoyun E. The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery. Arch Surg 2002;137:137-142.
-
(2002)
Arch Surg
, vol.137
, pp. 137-142
-
-
Siperstein, A.E.1
Berber, E.2
Morkoyun, E.3
-
6
-
-
85039573616
-
Performance of the electrothermal bipolar vessel sealer in 200 consecutive bowel resections
-
March 12-15, Los Angeles, California
-
Heniford BT, Harold KL, Matthews BD, Kercher KW, Carbonell AM, Sing RF. Performance of the electrothermal bipolar vessel sealer in 200 consecutive bowel resections. Presented at the Society of American Gastrointestinal Endoscopic Surgeons (SAGES) Annual Scientific Session and Postgraduate Course, March 12-15, 2003, Los Angeles, California.
-
(2003)
Society of American Gastrointestinal Endoscopic Surgeons (SAGES) Annual Scientific Session and Postgraduate Course
-
-
Heniford, B.T.1
Harold, K.L.2
Matthews, B.D.3
Kercher, K.W.4
Carbonell, A.M.5
Sing, R.F.6
-
7
-
-
0041527489
-
Electrocautery, argon beam coagulation, cryotherapy, and other hemostatic and tissue ablative instruments
-
Nyhus LM, Baker RJ, Fischer JE, (eds.). Boston: Little, Brown and Company
-
Hurst RD, Fichera A, Michelassi F. Electrocautery, argon beam coagulation, cryotherapy, and other hemostatic and tissue ablative instruments. In Nyhus LM, Baker RJ, Fischer JE, (eds.): Mastery of Surgery, Vol. I. Boston: Little, Brown and Company, 1997, pp. 234-245.
-
(1997)
Mastery of Surgery
, vol.1
, pp. 234-245
-
-
Hurst, R.D.1
Fichera, A.2
Michelassi, F.3
-
8
-
-
85039588305
-
-
Gyrus Medical PlasmaKinetic generator. Available at: http://www.gyrusmedical.com/products-plasmakinetics. asp?action=productview& ProductID=74. Accessed September 24, 2003.
-
Gyrus Medical PlasmaKinetic Generator
-
-
|