메뉴 건너뛰기




Volumn 516, Issue 2-3, 2004, Pages 315-326

Evaluation and reduction of ion back-flow in multi-GEM detectors

Author keywords

Gaseous detectors; Gaseous photomultiplier; GEM; Ion back flow; Ion feedback; Ion gating

Indexed keywords

AMPLIFICATION; AVALANCHE DIODES; HEAVY IONS; LIGHT POLARIZATION; PARTICLE DETECTORS; PHOTOCATHODES; PHOTONS; SECONDARY EMISSION; ULTRAVIOLET LAMPS;

EID: 0348107105     PISSN: 01689002     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.nima.2003.08.156     Document Type: Article
Times cited : (50)

References (25)
  • 14
    • 0041926524 scopus 로고    scopus 로고
    • Electron collection and ion feedback in GEM-based detectors
    • to be published
    • F. Sauli, et al., Electron collection and ion feedback in GEM-based detectors, IEEE Trans. Nucl. Sci., to be published.
    • IEEE Trans. Nucl. Sci.
    • Sauli, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.