메뉴 건너뛰기




Volumn 35, Issue 6, 2003, Pages 536-538

Intra-aortic balloon pump related thrombosis of the abdominal aorta resulting in visceral ischaemia [3]

Author keywords

[No Author keywords available]

Indexed keywords

ABDOMINAL AORTA; AGED; AORTA BALLOON; AORTA THROMBOSIS; BYPASS SURGERY; CASE REPORT; CORONARY ARTERY BYPASS GRAFT; CORONARY ARTERY DISEASE; CORONARY STENT; HUMAN; INTERNAL MAMMARY ARTERY; INTESTINE ISCHEMIA; LEFT ANTERIOR DESCENDING CORONARY ARTERY; LETTER; MALE; SAPHENOUS VEIN; VEIN GRAFT;

EID: 0348047342     PISSN: 00313025     EISSN: None     Source Type: Journal    
DOI: 10.1080/00313020310001619160     Document Type: Article
Times cited : (1)

References (9)
  • 2
  • 3
    • 0018857017 scopus 로고
    • Complications of the intraaortic balloon counterpulsation device: Clinical and morphologic observations in 45 necropsy patients
    • Isner J, Cohen S, Virmani R, Lawrinson W, William R. Complications of the intraaortic balloon counterpulsation device: clinical and morphologic observations in 45 necropsy patients. Am J Cardiol 1980; 45(2): 260-8.
    • (1980) Am J Cardiol , vol.45 , Issue.2 , pp. 260-268
    • Isner, J.1    Cohen, S.2    Virmani, R.3    Lawrinson, W.4    William, R.5
  • 4
    • 0036210314 scopus 로고    scopus 로고
    • Mortality and morbidity from intra-aortic balloon pump - Risk analysis
    • Meco M, Gramegna A, Yassini A, et al. Mortality and morbidity from intra-aortic balloon pump - risk analysis. J Cardiovasc Surg 2002; 43(1): 17-23.
    • (2002) J Cardiovasc Surg , vol.43 , Issue.1 , pp. 17-23
    • Meco, M.1    Gramegna, A.2    Yassini, A.3
  • 5
    • 0019846931 scopus 로고
    • Superior mesenteric artery obstruction by intraaortic counterpulsation balloon simulating embolism: A case report
    • Karlson K, Martin E, Bregman D, Fankuchen E, Casarella W. Superior mesenteric artery obstruction by intraaortic counterpulsation balloon simulating embolism: A case report. Cardiovasc Intervent Radiol 1981; 4(4): 236-8.
    • (1981) Cardiovasc Intervent Radiol , vol.4 , Issue.4 , pp. 236-238
    • Karlson, K.1    Martin, E.2    Bregman, D.3    Fankuchen, E.4    Casarella, W.5
  • 6
    • 0034177074 scopus 로고    scopus 로고
    • Acute ischemic hepatic failure resulting from intraaortic balloon pump malposition
    • Shin H, Yozu R, Sumida T, Kawada S. Acute ischemic hepatic failure resulting from intraaortic balloon pump malposition. Eur J Cardiothorac Surg 2000; 17(4): 492-4.
    • (2000) Eur J Cardiothorac Surg , vol.17 , Issue.4 , pp. 492-494
    • Shin, H.1    Yozu, R.2    Sumida, T.3    Kawada, S.4
  • 7
    • 0029795094 scopus 로고    scopus 로고
    • Acute pancreatitis associated with intra-aortic balloon pump placement
    • Rizk A, Rashkow A. Acute pancreatitis associated with intra-aortic balloon pump placement. Cathet Cardiovasc Diag 1996; 38: 363-4.
    • (1996) Cathet Cardiovasc Diag , vol.38 , pp. 363-364
    • Rizk, A.1    Rashkow, A.2
  • 9
    • 0019952187 scopus 로고
    • Bilateral renal artery thrombotic occlusion: A unique complication following removal of a transthoracic intraaortic balloon
    • Baciewicz F, Kaplan B, Murphy T, Neiman H. Bilateral renal artery thrombotic occlusion: a unique complication following removal of a transthoracic intraaortic balloon. Ann Thorac Surg 1982; 33(6): 631-4.
    • (1982) Ann Thorac Surg , vol.33 , Issue.6 , pp. 631-634
    • Baciewicz, F.1    Kaplan, B.2    Murphy, T.3    Neiman, H.4