메뉴 건너뛰기




Volumn 29, Issue 12, 2003, Pages 2318-2323

Understanding, retaining, and removing dispersive and pseudodispersive ophthalmic viscosurgical devices

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; ASPIRATION; CALCULATION; CANADA; CORRELATION ANALYSIS; DEVICE; DISPERSION; EYE SURGERY; FLOW KINETICS; HOSPITAL; LAVAGE; LENS IMPLANT; LIQUID; PRIORITY JOURNAL; SURGICAL INSTRUMENT; VISCOSITY;

EID: 0347989507     PISSN: 08863350     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jcrs.2003.09.045     Document Type: Article
Times cited : (34)

References (11)
  • 1
    • 85030932019 scopus 로고    scopus 로고
    • inventor; Biotrics, Inc, assignee. Ultrapure hyaluronic acid and the use thereof. US patent 4 141 973. February 27, 1979
    • Balazs EA, inventor; Biotrics, Inc, assignee. Ultrapure hyaluronic acid and the use thereof. US patent 4 141 973. February 27, 1979
    • Balazs, E.A.1
  • 2
    • 0001793450 scopus 로고
    • Dispersive and cohesive viscoelastic materials in phacoemulsification
    • Arshinoff SA. Dispersive and cohesive viscoelastic materials in phacoemulsification. Ophthalmic Pract 1995; 13:98-104
    • (1995) Ophthalmic Pract , vol.13 , pp. 98-104
    • Arshinoff, S.A.1
  • 3
    • 0032952529 scopus 로고    scopus 로고
    • Dispersive-cohesive viscoelastic soft shell technique
    • Arshinoff SA. Dispersive-cohesive viscoelastic soft shell technique. J Cataract Refract Surg 1999; 25:167-173
    • (1999) J Cataract Refract Surg , vol.25 , pp. 167-173
    • Arshinoff, S.A.1
  • 4
    • 0002112321 scopus 로고    scopus 로고
    • Dispersive and cohesive viscoelastic materials in phacoemulsification revisited 1998
    • Arshinoff SA. Dispersive and cohesive viscoelastic materials in phacoemulsification revisited 1998. Ophthalmic Pract 1998; 16:24-32
    • (1998) Ophthalmic Pract , vol.16 , pp. 24-32
    • Arshinoff, S.A.1
  • 5
    • 0000195212 scopus 로고    scopus 로고
    • Why Healon5? The meaning of "viscoadaptive"
    • Arshinoff SA. Why Healon5? The meaning of "viscoadaptive". Ophthalmic Pract 1999; 17:332-334
    • (1999) Ophthalmic Pract , vol.17 , pp. 332-334
    • Arshinoff, S.A.1
  • 6
    • 0002094478 scopus 로고    scopus 로고
    • Healon5
    • Buratto L, Giardini P, Bellucci R, eds, Thorofare, NJ, Slack
    • Arshinoff SA. "Healon5." In: Buratto L, Giardini P, Bellucci R, eds, Viscoelastics in Ophthalmic Surgery. Thorofare, NJ, Slack, 2000; 393-399
    • (2000) Viscoelastics in Ophthalmic Surgery , pp. 393-399
    • Arshinoff, S.A.1
  • 8
    • 0030226886 scopus 로고    scopus 로고
    • Comparison of viscoelastic substances used on phacoemulsification
    • Hutz WW, Eckhardt HB, Kohnen T. Comparison of viscoelastic substances used on phacoemulsification. J Cataract Refract Surg 1996; 22:955-959
    • (1996) J Cataract Refract Surg , vol.22 , pp. 955-959
    • Hutz, W.W.1    Eckhardt, H.B.2    Kohnen, T.3
  • 10
    • 0034109128 scopus 로고    scopus 로고
    • Two-compartment technique to remove ophthalmic viscosurgical devices
    • Tetz MR, Holzer MP. Two-compartment technique to remove ophthalmic viscosurgical devices. J Cataract Refract Surg 2000; 26:641-643
    • (2000) J Cataract Refract Surg , vol.26 , pp. 641-643
    • Tetz, M.R.1    Holzer, M.P.2
  • 11
    • 0036734185 scopus 로고    scopus 로고
    • Using BSS with viscoadaptives in the ultimate soft-shell technique
    • Arshinoff SA. Using BSS with viscoadaptives in the ultimate soft-shell technique. J Cataract Refract Surg 2002; 28:1509-1514
    • (2002) J Cataract Refract Surg , vol.28 , pp. 1509-1514
    • Arshinoff, S.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.