메뉴 건너뛰기




Volumn 17, Issue 5, 2002, Pages 287-292

Activated clotting time systems vary in precision and bias and are not interchangeable when following heparin management protocols during cardiopulmonary bypass

Author keywords

Angioplasty; Blood coagulation tests mt methods ; Cardiopulmonary bypass; Equipment design; Heparin ad administration dosage ; Human; Percutaneous coronary; Transluminal; Whole blood coagulation time.

Indexed keywords

CARDIOVASCULAR SYSTEM; COAGULATION; PATIENT MONITORING; PULMONARY DISEASES;

EID: 0347928631     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1021298103264     Document Type: Article
Times cited : (30)

References (18)
  • 2
    • 0014004037 scopus 로고
    • Activated coagulation time of whole blood
    • Hattersley PC. Activated coagulation time of whole blood. JAMA 1966; 196: 436-444
    • (1966) JAMA , vol.196 , pp. 436-444
    • Hattersley, P.C.1
  • 4
    • 0018917017 scopus 로고
    • Clinical experience with the activated clotting time for the control of heparin and protamine therapy during cardiopulmonary bypass
    • Akl BF, Vargas GM, Neal J, Robillard J, Kelly P. Clinical experience with the activated clotting time for the control of heparin and protamine therapy during cardiopulmonary bypass. J Thorac Cardiovasc Surg 1980; 79 (1): 97-102
    • (1980) J Thorac Cardiovasc Surg , vol.79 , Issue.1 , pp. 97-102
    • Akl, B.F.1    Vargas, G.M.2    Neal, J.3    Robillard, J.4    Kelly, P.5
  • 5
    • 0021981383 scopus 로고
    • Blood transfusion requirements in coronary artery surgery with and without the activated clotting time (ACT) technique
    • Preiss DU, Schmidt-Bleibtreu H, Berguson P, Metz G. Blood transfusion requirements in coronary artery surgery with and without the activated clotting time (ACT) technique. Klin Wochenschr 1985; 63 (6): 252-256
    • (1985) Klin Wochenschr , vol.63 , Issue.6 , pp. 252-256
    • Preiss, D.U.1    Schmidt-Bleibtreu, H.2    Berguson, P.3    Metz, G.4
  • 6
    • 0017625789 scopus 로고
    • Control of heparinization by activated clotting time during bypass with improved postoperative hemostasis
    • Verska JJ. Control of heparinization by activated clotting time during bypass with improved postoperative hemostasis. Ann Thorac Surg 1977; 24 (2): 170-173
    • (1977) Ann Thorac Surg , vol.24 , Issue.2 , pp. 170-173
    • Verska, J.J.1
  • 7
    • 0032818162 scopus 로고    scopus 로고
    • Anticoagulation and anticoagulation reversal with cardiac surgery involving cardiopulmonary bypass: An update
    • discussion 36-37
    • Despotis GJ, Joist JH. Anticoagulation and anticoagulation reversal with cardiac surgery involving cardiopulmonary bypass: An update. J Cardiothorac Vasc Anesth 1999; 13 (4 Suppl 1): 18-29; discussion 36-37
    • (1999) J Cardiothorac Vasc Anesth , vol.13 , Issue.4 SUPPL. 1 , pp. 18-29
    • Despotis, G.J.1    Joist, J.H.2
  • 9
    • 0018135359 scopus 로고
    • Adequate anticoagulation during cardiopulmonary bypass determined by activated clotting time and the appearance of fibrin monomer
    • Young JA, Kisker CT, Doty DB. Adequate anticoagulation during cardiopulmonary bypass determined by activated clotting time and the appearance of fibrin monomer. Ann Thorac Surg 1978; 26 (3): 231-240
    • (1978) Ann Thorac Surg , vol.26 , Issue.3 , pp. 231-240
    • Young, J.A.1    Kisker, C.T.2    Doty, D.B.3
  • 10
    • 0026547156 scopus 로고
    • An evaluation of two activated clotting time monitors during cardiac surgery
    • Reich DL, Zhal K, Perucho MH, Thys DM. An evaluation of two activated clotting time monitors during cardiac surgery. J Clin Monit 1992; 8 (1): 33-36
    • (1992) J Clin Monit , vol.8 , Issue.1 , pp. 33-36
    • Reich, D.L.1    Zhal, K.2    Perucho, M.H.3    Thys, D.M.4
  • 11
    • 0028261576 scopus 로고
    • Comparison of Hemochron and HemoTec activated coagulation time target values during percutaneous transluminal coronary angioplasty
    • Avendano A, Ferguson JJ. Comparison of Hemochron and HemoTec activated coagulation time target values during percutaneous transluminal coronary angioplasty. J Am Coll Cardiol 1994; 23 (4): 907-910
    • (1994) J Am Coll Cardiol , vol.23 , Issue.4 , pp. 907-910
    • Avendano, A.1    Ferguson, J.J.2
  • 12
    • 0035123838 scopus 로고    scopus 로고
    • An investigation of a new activated clotting time "MAX-ACT" in patients undergoing extracorporeal circulation
    • Leyvi G, Shore-Lesserson L, Harrington D, Vela-Cantos F, Hossain S. An investigation of a new activated clotting time "MAX-ACT" in patients undergoing extracorporeal circulation. Anesth Analg 2001; 92 (3): 578-583
    • (2001) Anesth Analg , vol.92 , Issue.3 , pp. 578-583
    • Leyvi, G.1    Shore-Lesserson, L.2    Harrington, D.3    Vela-Cantos, F.4    Hossain, S.5
  • 13
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1 (8476): 307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0034112185 scopus 로고    scopus 로고
    • Maintenance of blood heparin concentration rather than activated clotting time better preserves the coagulation system in hypothermic cardiopulmonary bypass
    • Shirota K, Watanabe T, Takagi Y, Ohara Y, Usui A, Yasuura K. Maintenance of blood heparin concentration rather than activated clotting time better preserves the coagulation system in hypothermic cardiopulmonary bypass. Artif Organs 2000; 24 (1): 49-56
    • (2000) Artif Organs , vol.24 , Issue.1 , pp. 49-56
    • Shirota, K.1    Watanabe, T.2    Takagi, Y.3    Ohara, Y.4    Usui, A.5    Yasuura, K.6
  • 17
    • 0029052424 scopus 로고
    • The impact of heparin concentration and activated clotting time monitoring on blood conservation. A prospective, randomized evaluation in patients undergoing cardiac operation
    • Despotis GJ, Joist JH, Hogue CW, Jr. et al. The impact of heparin concentration and activated clotting time monitoring on blood conservation. A prospective, randomized evaluation in patients undergoing cardiac operation. J Thorac Cardiovasc Surg 1995; 110 (1): 46-54
    • (1995) J Thorac Cardiovasc Surg , vol.110 , Issue.1 , pp. 46-54
    • Despotis, G.J.1    Joist, J.H.2    Hogue C.W., Jr.3
  • 18
    • 0030028375 scopus 로고    scopus 로고
    • Factors associated with excessive postoperative blood loss and hemostatic transfusion requirements: A multivariate analysis in cardiac surgical patients
    • Despotis GJ, Filos KS, Zoys TN, Hogue CW, Spitznagel E, Lappas DG. Factors associated with excessive postoperative blood loss and hemostatic transfusion requirements: A multivariate analysis in cardiac surgical patients. Anesth Analg 1996; 82 (1): 13-21
    • (1996) Anesth Analg , vol.82 , Issue.1 , pp. 13-21
    • Despotis, G.J.1    Filos, K.S.2    Zoys, T.N.3    Hogue, C.W.4    Spitznagel, E.5    Lappas, D.G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.