메뉴 건너뛰기




Volumn 18, Issue 1, 2004, Pages 28-33

Results of palmar plating of the lunate facet combined with external fixation for the treatment of high-energy compression fractures of the distal radius

Author keywords

Compression fractures; Distal radius; External fixation; Lunate facet; Palmar plating

Indexed keywords

ADULT; AGE; ARTICLE; BONE PLATE; BONE RADIOGRAPHY; CLINICAL ARTICLE; CONTROLLED STUDY; EXTERNAL FIXATOR; FEMALE; FOLLOW UP; FRACTURE EXTERNAL FIXATION; FRACTURE REDUCTION; GRIP STRENGTH; HUMAN; JOINT CHARACTERISTICS AND FUNCTIONS; LUNATE BONE; MALE; METABOLIC BONE DISEASE; OPEN REDUCTION; OSTEOSYNTHESIS; PRIORITY JOURNAL; QUESTIONNAIRE; RADIUS; RADIUS FRACTURE; RATING SCALE; RETROSPECTIVE STUDY; SCORING SYSTEM; SURGICAL TECHNIQUE; TENOSYNOVITIS; TREATMENT OUTCOME; ULNA;

EID: 0347917138     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-200401000-00006     Document Type: Article
Times cited : (28)

References (28)
  • 2
    • 0022485799 scopus 로고
    • Intraarticular fractures of the distal end of the radius in young adults
    • Knirk JL, Jupiter JB. Intraarticular fractures of the distal end of the radius in young adults. J Bone Joint Surg. 1986;68A:647-659.
    • (1986) J. Bone Joint Surg. , vol.68 A , pp. 647-659
    • Knirk, J.L.1    Jupiter, J.B.2
  • 3
    • 0025364276 scopus 로고
    • Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius
    • Axelrod TS, McMurtry RY. Open reduction and internal fixation of comminuted, intraarticular fractures of the distal radius. J Hand Surg. 1990; 15A:1-11.
    • (1990) J. Hand Surg. , vol.15 A , pp. 1-11
    • Axelrod, T.S.1    McMurtry, R.Y.2
  • 4
    • 0025366726 scopus 로고
    • Intra-articular fractures of the distal radius: A cadaveric study to determine if ligamentotaxis restores radiopalmar tilt
    • Bartosh RA, Saldana MJ. Intra-articular fractures of the distal radius: a cadaveric study to determine if ligamentotaxis restores radiopalmar tilt. J Hand Surgery. 1990;15A:18-21.
    • (1990) J. Hand Surgery , vol.15 A , pp. 18-21
    • Bartosh, R.A.1    Saldana, M.J.2
  • 5
    • 0029035440 scopus 로고
    • Results of combined internal and external fixation for the treatment of severe AO-C3 fractures of the distal radius
    • Bass RL, Glair WF, Hubbard PP. Results of combined internal and external fixation for the treatment of severe AO-C3 fractures of the distal radius. J Hand Surgery. 1995;20A:373-381.
    • (1995) J. Hand Surgery , vol.20 A , pp. 373-381
    • Bass, R.L.1    Glair, W.F.2    Hubbard, P.P.3
  • 6
    • 0026335623 scopus 로고
    • Current concepts review. Fractures of the distal end of the radius
    • Jupiter JB. Current concepts review. Fractures of the distal end of the radius. J Bone Joint Surg. 1991;73A:461-469.
    • (1991) J. Bone Joint Surg. , vol.73 A , pp. 461-469
    • Jupiter, J.B.1
  • 7
    • 0027226343 scopus 로고
    • The operative treatment of intraarticular fractures of the distal radius
    • Jupiter JB, Lipton H. The operative treatment of intraarticular fractures of the distal radius. Clin Orthop. 1993;292:48-61.
    • (1993) Clin. Orthop. , vol.292 , pp. 48-61
    • Jupiter, J.B.1    Lipton, H.2
  • 8
    • 0026639210 scopus 로고
    • Open reduction and internal fixation for distal radius fractures
    • Missakian ML, Cooney WP, Amadio PC, et al. Open reduction and internal fixation for distal radius fractures. J Hand Surg. 1992;17A:745-755.
    • (1992) J. Hand Surg. , vol.17 A , pp. 745-755
    • Missakian, M.L.1    Cooney, W.P.2    Amadio, P.C.3
  • 9
    • 0028266946 scopus 로고
    • Factors affecting functional outcome of displaced intraarticular distal radius fractures
    • Trumble TE, Schmitt SR, Vedder NB. Factors affecting functional outcome of displaced intraarticular distal radius fractures. J Hand Surg. 1994;19A:325-340.
    • (1994) J. Hand Surg. , vol.19 A , pp. 325-340
    • Trumble, T.E.1    Schmitt, S.R.2    Vedder, N.B.3
  • 10
    • 0027518565 scopus 로고
    • Severe fractures of the distal radius: Effect of amount and duration of external fixator distraction on outcome
    • Kaempffe FA, Wheeler DR, Peimer CA, et al. Severe fractures of the distal radius: effect of amount and duration of external fixator distraction on outcome. J Hand Surg. 1993;18A:33-41.
    • (1993) J. Hand Surg. , vol.18 A , pp. 33-41
    • Kaempffe, F.A.1    Wheeler, D.R.2    Peimer, C.A.3
  • 11
    • 0029954867 scopus 로고    scopus 로고
    • Development of an upper extremity outcome measure: The DASH (Disabilities of the Arm, Shoulder, and Hand)
    • Hudak P, Amadio PC, Bombardier C, et al. Development of an upper extremity outcome measure: the DASH (Disabilities of the Arm, Shoulder, and Hand). Am J Indus Med. 1996;29:602-608.
    • (1996) Am. J. Indus. Med. , vol.29 , pp. 602-608
    • Hudak, P.1    Amadio, P.C.2    Bombardier, C.3
  • 12
    • 0035020852 scopus 로고    scopus 로고
    • Measuring the whole or the parts? Validity, reliability and responsiveness of the disabilities of the arm, shoulder, and hand outcome measure in different regions of the upper extremity
    • Beaton DE, Katz JN, Fossel AH, et al. Measuring the whole or the parts? Validity, reliability and responsiveness of the disabilities of the arm, shoulder, and hand outcome measure in different regions of the upper extremity. J Hand Therapy. 2001;14:128-146.
    • (2001) J. Hand Therapy , vol.14 , pp. 128-146
    • Beaton, D.E.1    Katz, J.N.2    Fossel, A.H.3
  • 13
    • 0017076151 scopus 로고
    • Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones
    • Gustillo RB, Anderson JT. Prevention of infection in the treatment of one thousand and twenty-five open fractures of long bones. J Bone Joint Surg. 1976;58A:453-458.
    • (1976) J. Bone Joint Surg. , vol.58 A , pp. 453-458
    • Gustillo, R.B.1    Anderson, J.T.2
  • 14
    • 0026073542 scopus 로고
    • External fixation for intraarticular fractures of the distal radius
    • Jakim I, Peiterese HS, Sweet MB. External fixation for intraarticular fractures of the distal radius. J Bone Joint Surg. 1991;73B:302-306.
    • (1991) J. Bone Joint Surg. , vol.73 B , pp. 302-306
    • Jakim, I.1    Peiterese, H.S.2    Sweet, M.B.3
  • 15
    • 0025987121 scopus 로고
    • Percutaneous and limited open reduction of the articular surface of the distal radius
    • Geissler WB, Fernandez DL. Percutaneous and limited open reduction of the articular surface of the distal radius. J Orthop Trauma. 1991;5:255-264.
    • (1991) J. Orthop. Trauma , vol.5 , pp. 255-264
    • Geissler, W.B.1    Fernandez, D.L.2
  • 16
    • 0026317894 scopus 로고
    • Augmented external fixation of unstable distal radius fractures
    • Seitz WH Jr, Froimson AI, Leb R, et al. Augmented external fixation of unstable distal radius fractures. J Hand Surg. 1991;16A:1010-1016.
    • (1991) J. Hand Surg. , vol.16 A , pp. 1010-1016
    • Seitz Jr., W.H.1    Froimson, A.I.2    Leb, R.3
  • 17
    • 0033779857 scopus 로고    scopus 로고
    • Pin reduction and fixation of volar fracture fragments of the distal radius fractures via the flexor carpi radialis tendon
    • Ziran BH, Scheel M, Keith MW. Pin reduction and fixation of volar fracture fragments of the distal radius fractures via the flexor carpi radialis tendon. J Trauma. 2000;49:433-439.
    • (2000) J. Trauma , vol.49 , pp. 433-439
    • Ziran, B.H.1    Scheel, M.2    Keith, M.W.3
  • 18
    • 0024389429 scopus 로고
    • Open reduction and internal fixation of displaced, comminuted intraarticular fractures of the distal end of the radius
    • Bradway JK, Amadio PC, Cooney WP. Open reduction and internal fixation of displaced, comminuted intraarticular fractures of the distal end of the radius. J Bone Joint Surg. 1989;71A:839-847.
    • (1989) J. Bone Joint Surg. , vol.71 A , pp. 839-847
    • Bradway, J.K.1    Amadio, P.C.2    Cooney, W.P.3
  • 19
    • 0030928604 scopus 로고    scopus 로고
    • Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures
    • Ring D, Jupiter JB, Brennwald J, et al. Prospective multicenter trial of a plate for dorsal fixation of distal radius fractures. J Hand Surg. 1997;22A: 777-784.
    • (1997) J. Hand Surg. , vol.22 A , pp. 777-784
    • Ring, D.1    Jupiter, J.B.2    Brennwald, J.3
  • 20
    • 0030767613 scopus 로고    scopus 로고
    • Displaced intraarticular fractures of the distal aspect of the radius. Long-term results in young adults after open reduction and internal fixation
    • Catalano LW 3rd, Cole RJ, Gelberman RH, et al. Displaced intraarticular fractures of the distal aspect of the radius. Long-term results in young adults after open reduction and internal fixation. J Bone Joint Surg. 1997; 79A:1290-1302.
    • (1997) J. Bone Joint Surg. , vol.79 A , pp. 1290-1302
    • Catalano III, L.W.1    Cole, R.J.2    Gelberman, R.H.3
  • 21
    • 0025817344 scopus 로고
    • Treatment of displaced articular fractures of the radius
    • Fernandez DL, Geissler WB. Treatment of displaced articular fractures of the radius. J Hand Surg. 1991;16A:375-384.
    • (1991) J. Hand Surg. , vol.16 A , pp. 375-384
    • Fernandez, D.L.1    Geissler, W.B.2
  • 22
    • 0025356403 scopus 로고
    • An effective treatment of comminuted fractures of the distal radius
    • Leung KS, Shen WY, Tsang HK, et al. An effective treatment of comminuted fractures of the distal radius. J Hand Surg. 1990;15A:11-17.
    • (1990) J. Hand Surg. , vol.15 A , pp. 11-17
    • Leung, K.S.1    Shen, W.Y.2    Tsang, H.K.3
  • 23
    • 0027461687 scopus 로고
    • Fractures of the distal end of the radius in young adults: A 30-year follow-up
    • Kopylov P, Johnell O, Redlund-Johnell I, et al. Fractures of the distal end of the radius in young adults: a 30-year follow-up. J Hand Surg. 1993; 18B:45-49.
    • (1993) J. Hand Surg. , vol.18 B , pp. 45-49
    • Kopylov, P.1    Johnell, O.2    Redlund-Johnell, I.3
  • 24
    • 0032720912 scopus 로고    scopus 로고
    • Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius
    • Nunley JA, Rowan PR. Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius. J Hand Surgery. 1999;24A:1279-1280.
    • (1999) J. Hand Surgery , vol.24 A , pp. 1279-1280
    • Nunley, J.A.1    Rowan, P.R.2
  • 25
    • 0034068196 scopus 로고    scopus 로고
    • Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft fur osteosynthesefragen/Association for the Study of Internal Fixation
    • Schnur DP, Chang B. Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO/ASIF titanium pi plate. Arbeitsgemeinschaft fur osteosynthesefragen/Association for the Study of Internal Fixation. Ann Plast Surg. 2000;44:564-566.
    • (2000) Ann. Plast. Surg. , vol.44 , pp. 564-566
    • Schnur, D.P.1    Chang, B.2
  • 26
    • 0023941944 scopus 로고
    • Limited open reduction of the lunate facet in comminuted intraarticular fractures of the distal radius
    • Axelrod TS, Paley D, Green J, et al. Limited open reduction of the lunate facet in comminuted intraarticular fractures of the distal radius. J Hand Surg. 1988;13A:372-377.
    • (1988) J. Hand Surg. , vol.13 A , pp. 372-377
    • Axelrod, T.S.1    Paley, D.2    Green, J.3
  • 27
    • 0035069761 scopus 로고    scopus 로고
    • Treatment of severely comminuted intraarticular fractures of the distal end of the radius by open reduction and combined internal and external fixation
    • Rogachefsky RA, Lipson SR, Applegate B, et al. Treatment of severely comminuted intraarticular fractures of the distal end of the radius by open reduction and combined internal and external fixation. J Bone Joint Surg. 2001;83A:509-519.
    • (2001) J. Bone Joint Surg. , vol.83 A , pp. 509-519
    • Rogachefsky, R.A.1    Lipson, S.R.2    Applegate, B.3
  • 28
    • 0032460038 scopus 로고    scopus 로고
    • Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: A brief report
    • Kambouroglou GK, Axelrod TS. Complications of the AO/ASIF titanium distal radius plate system (pi plate) in internal fixation of the distal radius: a brief report. J Hand Surg. 1998;23A:737-741.
    • (1998) J. Hand Surg. , vol.23 A , pp. 737-741
    • Kambouroglou, G.K.1    Axelrod, T.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.