메뉴 건너뛰기




Volumn 14, Issue 5, 2003, Pages 356-357

Sinus formation after insertion of a silicone-coated suburethral sling

Author keywords

Fistula; Silicone; Sinus; Sling

Indexed keywords

AGED; ARTICLE; CASE REPORT; DEBRIDEMENT; EROSION; FEMALE; HUMAN; MATERIAL COATING; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; RECTUS ABDOMINIS MUSCLE; SILICONE PROSTHESIS; SURGICAL EQUIPMENT; SURGICAL TECHNIQUE; URETHRA SURGERY; URETHROPLASTY; UROGENITAL SINUS;

EID: 0347765780     PISSN: 09373462     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00192-003-1065-0     Document Type: Article
Times cited : (7)

References (9)
  • 1
    • 0342365746 scopus 로고
    • Sub-urethral sling procedures: When should they be performed?
    • Owen RG (1992) Sub-urethral sling procedures: When should they be performed? Int Urogynecol J 3:283-286
    • (1992) Int. Urogynecol. J. , vol.3 , pp. 283-286
    • Owen, R.G.1
  • 2
    • 0028334774 scopus 로고
    • Surgery for genuine stress incontinence
    • Jarvis GJ (1994) Surgery for genuine stress incontinence. Br J Obstet Gynaecol 101:371-374
    • (1994) Br. J. Obstet. Gynaecol. , vol.101 , pp. 371-374
    • Jarvis, G.J.1
  • 4
    • 0024338050 scopus 로고
    • Experience with silastic slings for female urinary incontinence
    • Korda A. Peat B, Hunter P (1989) Experience with silastic slings for female urinary incontinence. Aust NZ J Obstet Gynaecol 29:150-154
    • (1989) Aust. NZ J. Obstet. Gynaecol. , vol.29 , pp. 150-154
    • Korda, A.1    Peat, B.2    Hunter, P.3
  • 5
    • 0028962208 scopus 로고
    • A follow-up of silastic sling for genuine stress incontinence
    • Chin YK, Stanton SL (1995) A follow-up of silastic sling for genuine stress incontinence. Br J Obstet Gynaecol 102:143-147
    • (1995) Br. J. Obstet. Gynaecol. , vol.102 , pp. 143-147
    • Chin, Y.K.1    Stanton, S.L.2
  • 6
    • 0029052284 scopus 로고
    • Long-term clinical and urodynamics evaluation of the polytetrafluoroethylene suburethral sling for treatment of genuine stress incontinence
    • Weinberger MW, Ostegard DR (1995) Long-term clinical and urodynamics evaluation of the polytetrafluoroethylene suburethral sling for treatment of genuine stress incontinence. Obstet Gynecol 86:92-96
    • (1995) Obstet. Gynecol. , vol.86 , pp. 92-96
    • Weinberger, M.W.1    Ostegard, D.R.2
  • 7
    • 0034048138 scopus 로고    scopus 로고
    • Complications of silicone insertion for stress urinary incontinence
    • Duckett JR, Constantine G (2000) Complications of silicone insertion for stress urinary incontinence. J Urol 163:1835-1837
    • (2000) J. Urol. , vol.163 , pp. 1835-1837
    • Duckett, J.R.1    Constantine, G.2
  • 8
    • 0027138108 scopus 로고
    • Tissue reaction to expanded polytetrafluoroethylene suburethral sling for urinary incontinence: Clinical and histologic study
    • Bent AE. Ostegard DR. Zwick-Zaffuto MT (1993) Tissue reaction to expanded polytetrafluoroethylene suburethral sling for urinary incontinence: clinical and histologic study. Am J Obstet Gynecol 169:1198-1204
    • (1993) Am. J. Obstet. Gynecol. , vol.169 , pp. 1198-1204
    • Bent, A.E.1    Ostegard, D.R.2    Zwick-Zaffuto, M.T.3
  • 9
    • 0028940939 scopus 로고
    • Modified pubovaginal sling and Martius graft for repair of the recurrent vesicovaginal fistula involving the internal urinary sphincter
    • Ghoneim GM, Monga M (1995) Modified pubovaginal sling and Martius graft for repair of the recurrent vesicovaginal fistula involving the internal urinary sphincter. Eur Urol 27:241-245
    • (1995) Eur. Urol. , vol.27 , pp. 241-245
    • Ghoneim, G.M.1    Monga, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.