메뉴 건너뛰기




Volumn 48, Issue 1-3, 1998, Pages 308-317

A screen-printed amperometric dissolved oxygen sensor utilising an immobilised electrolyte gel and membrane

Author keywords

Dissolved oxygen sensor; Membrane covered sensor; Oxygen reduction; Potentiostatic measurement; Screen printing; Thick film sensor

Indexed keywords


EID: 0347649430     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(98)00063-X     Document Type: Article
Times cited : (15)

References (16)
  • 4
    • 0022559382 scopus 로고
    • A thick-film multiple component three electrode sensor
    • V. Karagounis, L. Lun, C.C. Liu, A thick-film multiple component three electrode sensor, IEEE Trans. Biomed-eng., BME-33 2 (1986) 108-112.
    • (1986) IEEE Trans. Biomed-eng. , vol.BME-33 , Issue.2 , pp. 108-112
    • Karagounis, V.1    Lun, L.2    Liu, C.C.3
  • 5
    • 0023306484 scopus 로고
    • In vitro stability of an oxygen sensor
    • J. Lucisano, J. Armour, D. Gough, In vitro stability of an oxygen sensor, Anal. Chem. 59 (1987) 736-739.
    • (1987) Anal. Chem. , vol.59 , pp. 736-739
    • Lucisano, J.1    Armour, J.2    Gough, D.3
  • 6
    • 0027544481 scopus 로고
    • An auto-calibrated miniature microhole cathode array for measuring dissolved oxygen
    • Y.-O. Chen, G. Li, An auto-calibrated miniature microhole cathode array for measuring dissolved oxygen, Sensors and Actuators B 10 (1993) 219-222.
    • (1993) Sensors and Actuators B , vol.10 , pp. 219-222
    • Chen, Y.-O.1    Li, G.2
  • 9
    • 0025503255 scopus 로고
    • Problems associated with the miniaturisation of a voltammetric oxygen sensor: Chemical crosstalk among electrodes
    • C. Sha, M. Shao, C.C. Liu, Problems associated with the miniaturisation of a voltammetric oxygen sensor: chemical crosstalk among electrodes, Sensors and Actuators B 2 (1990) 239-242.
    • (1990) Sensors and Actuators B , vol.2 , pp. 239-242
    • Sha, C.1    Shao, M.2    Liu, C.C.3
  • 14
    • 0017874628 scopus 로고
    • A fast stabilisation technique for oxygen sensors with low cathode current densities
    • W.F. Mindt, P. Eberhard, A fast stabilisation technique for oxygen sensors with low cathode current densities, Acta Annaesth. Scand. Suppl. 68 (1978) 63-67.
    • (1978) Acta Annaesth. Scand. Suppl. , vol.68 , pp. 63-67
    • Mindt, W.F.1    Eberhard, P.2
  • 15
    • 0011739614 scopus 로고
    • Some considerations of the steady-state and transient behaviour of membrane-covered dissolved oxygen detectors
    • J.M. Hale, M.L. Hitchman, Some considerations of the steady-state and transient behaviour of membrane-covered dissolved oxygen detectors, J. Electroanal. Chem. 107 (1980) 281-294.
    • (1980) J. Electroanal. Chem. , vol.107 , pp. 281-294
    • Hale, J.M.1    Hitchman, M.L.2
  • 16
    • 0021469027 scopus 로고
    • An experimental study of oxygen probe linearity and transient characteristics in the high oxygen concentration range
    • V. Linek, P. Beneš, V. Vacek, An experimental study of oxygen probe linearity and transient characteristics in the high oxygen concentration range, J. Electroanal. Chem. 169 (1984) 233-257.
    • (1984) J. Electroanal. Chem. , vol.169 , pp. 233-257
    • Linek, V.1    Beneš, P.2    Vacek, V.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.