메뉴 건너뛰기




Volumn 74, Issue 6, 2003, Pages 658-660

Early bead shedding of the Vitalock acetabular cup - A report on 7 cases

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ARTICLE; CLINICAL ARTICLE; CLINICAL EXAMINATION; CONTROLLED STUDY; ENDOPROSTHESIS; ENDOPROSTHESIS LOOSENING; FOLLOW UP; HIP PROSTHESIS; HIP RADIOGRAPHY; HUMAN; JOINT STABILITY; OSTEOLYSIS; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; SURGICAL TECHNIQUE; TOTAL HIP PROSTHESIS; TREATMENT OUTCOME;

EID: 0347601723     PISSN: 00016470     EISSN: None     Source Type: Journal    
DOI: 10.1080/00016470310018153     Document Type: Article
Times cited : (9)

References (13)
  • 2
    • 0028028328 scopus 로고
    • Pain in the thigh following total hip replacement with a Porous-Coated Anatomic prosthesis for osteoarthrosis
    • Am
    • Bourne R B, Rorabeck C H, Ghazal M E, Lee M H. Pain in the thigh following total hip replacement with a Porous-Coated Anatomic prosthesis for osteoarthrosis. J Bone Joint Surg (Am) 1994; 76: 1464-70.
    • (1994) J Bone Joint Surg , vol.76 , pp. 1464-1470
    • Bourne, R.B.1    Rorabeck, C.H.2    Ghazal, M.E.3    Lee, M.H.4
  • 3
    • 0022532235 scopus 로고
    • Excessive metal release due to loosening and fretting of sintered particles on porous-coated hip prostheses
    • Am
    • Buchert P K, Vaughn B K, Mallory T H, Engh C A, Bobyn D. Excessive metal release due to loosening and fretting of sintered particles on porous-coated hip prostheses. J Bone Joint Surg (Am) 1986; 68: 606-9.
    • (1986) J Bone Joint Surg , vol.68 , pp. 606-609
    • Buchert, P.K.1    Vaughn, B.K.2    Mallory, T.H.3    Engh, C.A.4    Bobyn, D.5
  • 4
    • 0023946442 scopus 로고
    • The uncemented Porous-Coated Anatomic total hip replacement
    • Am
    • Callaghan J J, Dysart S H, Savory C G. The uncemented Porous-Coated Anatomic total hip replacement. J Bone Joint Surg (Am) 1988; 70: 337-46.
    • (1988) J Bone Joint Surg , vol.70 , pp. 337-346
    • Callaghan, J.J.1    Dysart, S.H.2    Savory, C.G.3
  • 5
    • 0023675987 scopus 로고
    • Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases
    • Davey J R, Harris W H. Loosening of cobalt chrome beads from a porous-coated acetabular component. A report of ten cases. Clin Orthop 1988; 231: 97-102.
    • (1988) Clin Orthop , vol.231 , pp. 97-102
    • Davey, J.R.1    Harris, W.H.2
  • 6
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • De Lee J G, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976; 121: 20-32.
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • De Lee, J.G.1    Charnley, J.2
  • 8
    • 0346164166 scopus 로고    scopus 로고
    • Hemispheric porous-coated acetabular component with and without screw fixation
    • Gil Garay E, Gomez Cordero P, Peleteiro Pensado P. Hemispheric porous-coated acetabular component with and without screw fixation. Hip Int 2000; 10: 248.
    • (2000) Hip Int , vol.10 , pp. 248
    • Gil Garay, E.1    Gomez Cordero, P.2    Peleteiro Pensado, P.3
  • 11
    • 0026736673 scopus 로고
    • Bead loosening from a porous-coated acetabular component. A follow-up note
    • Maloney W J, Davey J R, Harris W H. Bead loosening from a porous-coated acetabular component. A follow-up note. Clin Orthop 1992; 281: 112-4.
    • (1992) Clin Orthop , vol.281 , pp. 112-114
    • Maloney, W.J.1    Davey, J.R.2    Harris, W.H.3
  • 13
    • 0030768857 scopus 로고    scopus 로고
    • Incidence of late bead shedding from uncemented porous coated cups. A radiographic evaluation
    • von Knoch M, Sychterz C J, Anderson Engh C, Engh C A. Incidence of late bead shedding from uncemented porous coated cups. A radiographic evaluation. Clin Orthop 1997; 342: 99-105.
    • (1997) Clin Orthop , vol.342 , pp. 99-105
    • Von Knoch, M.1    Sychterz, C.J.2    Anderson Engh, C.3    Engh, C.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.