1
-
-
0032924963
-
Socket considerations for the patient with a transtibial amputation
-
Fergason J.; Smith D.G., Socket considerations for the patient with a transtibial amputation. Clinical Orthopaedics & Related Research, (361):76-84, 1999.
-
(1999)
Clinical Orthopaedics & Related Research
, Issue.361
, pp. 76-84
-
-
Fergason, J.1
Smith, D.G.2
-
2
-
-
0032033824
-
Effect of alignment changes on stance phase pressures and shear stresses on transtibial amputees: Measurements from 13 transducer sites
-
Sander J.E.; Bell D.M.; Okumura R.M.; Dralle A.J., Effect of alignment changes on stance phase pressures and shear stresses on transtibial amputees: measurements from 13 transducer sites. IEEE Transactions on Rehabilitation Engineering., 6: 21-31, 1998.
-
(1998)
IEEE Transactions on Rehabilitation Engineering
, vol.6
, pp. 21-31
-
-
Sander, J.E.1
Bell, D.M.2
Okumura, R.M.3
Dralle, A.J.4
-
3
-
-
0026896837
-
Interface load analysis for computer-aided design of below-knee prosthetic sockets
-
Reynolds D.P.; Lord M., Interface load analysis for computer-aided design of below-knee prosthetic sockets. Medical & Biological Engineering & Computing., 30:419-426, 1992.
-
(1992)
Medical & Biological Engineering & Computing
, vol.30
, pp. 419-426
-
-
Reynolds, D.P.1
Lord, M.2
-
4
-
-
0032053296
-
Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis
-
Zhang M.; Turner-Smith A.R.; Tanner A.; Roberts V.C., Clinical investigation of the pressure and shear stress on the trans-tibial stump with a prosthesis. Medical Engineering & Physics, 20(3):188-98, 1998.
-
(1998)
Medical Engineering & Physics
, vol.20
, Issue.3
, pp. 188-198
-
-
Zhang, M.1
Turner-Smith, A.R.2
Tanner, A.3
Roberts, V.C.4
-
5
-
-
0029329286
-
Interface mechanics in external prosthetics: Review of interface stress measurement techniques
-
Sanders J.E., Interface mechanics in external prosthetics: review of interface stress measurement techniques. Medical & Biological Engineering & Computing, 33: 509-516, 1995.
-
(1995)
Medical & Biological Engineering & Computing
, vol.33
, pp. 509-516
-
-
Sanders, J.E.1
-
6
-
-
0027172620
-
Clinical measurement of normal and shear stresses on a trans-tibial stump: Characteristics of wave-form shapes during walking
-
Sanders J.E.; Daly C.H.; Burgess E.M., Clinical measurement of normal and shear stresses on a trans-tibial stump: characteristics of wave-form shapes during walking., Prosthetics and Orthotics Internatonal, 17, 38-48, 1993.
-
(1993)
Prosthetics and Orthotics Internatonal
, vol.17
, pp. 38-48
-
-
Sanders, J.E.1
Daly, C.H.2
Burgess, E.M.3
-
7
-
-
0030482286
-
Interface mechanics in lower-limb external prosthetics: A review of finite element models
-
Zachariah S.G.; Sanders J.E., Interface mechanics in lower-limb external prosthetics: a review of finite element models. IEEE Transactions on Rehabilitation Engineering., 4: 288-302, 1996.
-
(1996)
IEEE Transactions on Rehabilitation Engineering
, vol.4
, pp. 288-302
-
-
Zachariah, S.G.1
Sanders, J.E.2
-
8
-
-
0027612309
-
Measurement of stresses in three orthogonal directions at residual limb-prosthetic socket interface
-
Sander J.E.; Daly C.H., Measurement of stresses in three orthogonal directions at residual limb-prosthetic socket interface. IEEE Transactions on Rehabilitation Engineering., 1: 79-85, 1993.
-
(1993)
IEEE Transactions on Rehabilitation Engineering
, vol.1
, pp. 79-85
-
-
Sander, J.E.1
Daly, C.H.2
-
10
-
-
0034998521
-
Standing interface stresses as a predictor of walking interface stresses in the trans-tibial prosthesis
-
Zachariah S.G.; Sanders J.E., Standing interface stresses as a predictor of walking interface stresses in the trans-tibial prosthesis. Prosthetics & Orthotics International., 25(1):34-40, 2001.
-
(2001)
Prosthetics & Orthotics International
, vol.25
, Issue.1
, pp. 34-40
-
-
Zachariah, S.G.1
Sanders, J.E.2
-
11
-
-
0030843837
-
A new biomechanical method for determination of static prosthetic alignment
-
Blumentritt S., A new biomechanical method for determination of static prosthetic alignment. Prosthetics and Orthotics International 21: 107-113, 1997.
-
(1997)
Prosthetics and Orthotics International
, vol.21
, pp. 107-113
-
-
Blumentritt, S.1
|