메뉴 건너뛰기




Volumn 28, Issue 4, 2003, Pages 267-269

Evaluation of two water-equivalent phantom materials for output calibration of photon and electron beams

Author keywords

Beam calibration; Solid phantom; Water equivalency

Indexed keywords

WATER;

EID: 0347479355     PISSN: 09583947     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.meddos.2003.09.001     Document Type: Article
Times cited : (14)

References (8)
  • 1
    • 0021062111 scopus 로고
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams
    • Erratum: A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 11:213; 1984
    • A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 10:1983;741-771. Erratum: A protocol for the determination of absorbed dose from high-energy photon and electron beams. Med. Phys. 11:213; 1984.
    • (1983) Med. Phys. , vol.10 , pp. 741-771
  • 2
    • 0032874911 scopus 로고    scopus 로고
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams
    • AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams. Med. Phys. 26:1999;1847-1870.
    • (1999) Med. Phys. , vol.26 , pp. 1847-1870
  • 3
    • 0020137053 scopus 로고
    • A solid water phantom material for radiotherapy x-ray and x-ray beam calibrations
    • Constantinou C., Attix F., Paliwal B. A solid water phantom material for radiotherapy x-ray and x-ray beam calibrations. Med. Phys. 9:1982;436-441.
    • (1982) Med. Phys. , vol.9 , pp. 436-441
    • Constantinou, C.1    Attix, F.2    Paliwal, B.3
  • 4
    • 0022506972 scopus 로고
    • Stopping-power and mass energy-absorption coefficient ratios for solid water
    • Ho A., Paliwal B. Stopping-power and mass energy-absorption coefficient ratios for solid water. Med. Phys. 31:1986;403-404.
    • (1986) Med. Phys. , vol.31 , pp. 403-404
    • Ho, A.1    Paliwal, B.2
  • 5
    • 0028908320 scopus 로고
    • Evaluation of water-equivalent plastics as phantom material for electron beam dosimetry
    • Thomadsen B., Constantinou C., Ho A. Evaluation of water-equivalent plastics as phantom material for electron beam dosimetry. Med. Phys. 22:1995;291.
    • (1995) Med. Phys. , vol.22 , pp. 291
    • Thomadsen, B.1    Constantinou, C.2    Ho, A.3
  • 6
    • 0027031494 scopus 로고
    • Comparison of absorbed doses in water and solid water for electron beams
    • Prasad S.C. Comparison of absorbed doses in water and solid water for electron beams. Med. Dosim. 17:1992;205-206.
    • (1992) Med. Dosim. , vol.17 , pp. 205-206
    • Prasad, S.C.1
  • 7
    • 0028566142 scopus 로고
    • A comparative study of dosimetric properties of plastic water and solid water in brachytherapy applications
    • Meigooni A.G., Li Z., Mishra V., Williamson J.F. A comparative study of dosimetric properties of plastic water and solid water in brachytherapy applications. Med. Phys. 21:1994;1983-1987.
    • (1994) Med. Phys. , vol.21 , pp. 1983-1987
    • Meigooni, A.G.1    Li, Z.2    Mishra, V.3    Williamson, J.F.4
  • 8
    • 0029113276 scopus 로고
    • How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams?
    • Tello V.M., Tailor R.C., Hanson W.F. How water equivalent are water-equivalent solid materials for output calibration of photon and electron beams? Med. Phys. 22:1995;1177-1189.
    • (1995) Med. Phys. , vol.22 , pp. 1177-1189
    • Tello, V.M.1    Tailor, R.C.2    Hanson, W.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.