메뉴 건너뛰기




Volumn 230, Issue 1, 2004, Pages 101-108

Evaluation of Lung Injury after Three-dimensional Conformal Stereotactic Radiation Therapy for Solitary Lung Tumors: CT Appearance

Author keywords

Lung neoplasms, CT; Lung neoplasms, therapeutic radiology; Radiations, injurious effects, complications of therapeutic radiology; Stereotaxis; Therapeutic radiology, three dimensional

Indexed keywords

ARTICLE; CANCER RADIOTHERAPY; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; DOSIMETRY; HUMAN; LINEAR ACCELERATOR; LUNG INJURY; LUNG TUMOR; PRIORITY JOURNAL; RADIATION DOSE; SIMULATOR; STEREOTAXIC SURGERY; TREATMENT OUTCOME; TUMOR VOLUME;

EID: 0347479227     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiol.2301021226     Document Type: Article
Times cited : (117)

References (25)
  • 1
    • 0028855915 scopus 로고
    • Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator: Clinical experience of the first thirty-one patients
    • Blomgren H, Lax I, Naslund I, Svanstrom R. Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator: clinical experience of the first thirty-one patients. Acta Oncol 1995; 34:861-870.
    • (1995) Acta Oncol , vol.34 , pp. 861-870
    • Blomgren, H.1    Lax, I.2    Naslund, I.3    Svanstrom, R.4
  • 3
    • 0035404395 scopus 로고    scopus 로고
    • Simple method of stereotactic radiotherapy without stereotactic body frame for extracranial tumors
    • Takai Y, Mituya M, Nemoto K, et al. Simple method of stereotactic radiotherapy without stereotactic body frame for extracranial tumors. Nippon Igaku Hoshasen Gakkai Zasshi 2001; 61:403-407.
    • (2001) Nippon Igaku Hoshasen Gakkai Zasshi , vol.61 , pp. 403-407
    • Takai, Y.1    Mituya, M.2    Nemoto, K.3
  • 4
    • 18344370445 scopus 로고    scopus 로고
    • Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame
    • Nagata Y, Negoro Y, Aoki T, et al. Clinical outcomes of 3D conformal hypofractionated single high-dose radiotherapy for one or two lung tumors using a stereotactic body frame. Int J Radiat Oncol Biol Phys 2002; 52:1041-1046.
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1041-1046
    • Nagata, Y.1    Negoro, Y.2    Aoki, T.3
  • 5
    • 0033828191 scopus 로고    scopus 로고
    • Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: Original research in the treatment of thoracic neoplasms
    • Nakagawa K, Aoki Y, Tago M, Terahara A, Ohtomo K. Megavoltage CT-assisted stereotactic radiosurgery for thoracic tumors: original research in the treatment of thoracic neoplasms. Int J Radiat Oncol Biol Phys 2000; 48:449-457.
    • (2000) Int J Radiat Oncol Biol Phys , vol.48 , pp. 449-457
    • Nakagawa, K.1    Aoki, Y.2    Tago, M.3    Terahara, A.4    Ohtomo, K.5
  • 6
    • 0035500881 scopus 로고    scopus 로고
    • Computed tomography-guided frameless stereotactic radiotherapy for stage I non-small cell lung cancer: A 5-year experience
    • Uematsu M, Shioda A, Suda A, et al. Computed tomography-guided frameless stereotactic radiotherapy for stage I non-small cell lung cancer: a 5-year experience. Int J Radiat Oncol Biol Phys 2001; 51:666-670.
    • (2001) Int J Radiat Oncol Biol Phys , vol.51 , pp. 666-670
    • Uematsu, M.1    Shioda, A.2    Suda, A.3
  • 7
    • 0032521265 scopus 로고    scopus 로고
    • Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients: A preliminary experience
    • Uematsu M, Shioda A, Tahara K, et al. Focal, high dose, and fractionated modified stereotactic radiation therapy for lung carcinoma patients: a preliminary experience. Cancer 1998; 82:1062-1070.
    • (1998) Cancer , vol.82 , pp. 1062-1070
    • Uematsu, M.1    Shioda, A.2    Tahara, K.3
  • 8
    • 0035879442 scopus 로고    scopus 로고
    • The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: Reduction of respiratory tumor movement and evaluation of the daily setup accuracy
    • Negoro Y, Nagata Y, Aoki T, et al. The effectiveness of an immobilization device in conformal radiotherapy for lung tumor: reduction of respiratory tumor movement and evaluation of the daily setup accuracy. Int J Radiat Oncol Biol Phys 2001; 50:889-898.
    • (2001) Int J Radiat Oncol Biol Phys , vol.50 , pp. 889-898
    • Negoro, Y.1    Nagata, Y.2    Aoki, T.3
  • 9
    • 0023860787 scopus 로고
    • CT appearance of acute radiation-induced injury in the lung
    • Ikezoe J, Takashima S, Morimoto S, et al. CT appearance of acute radiation-induced injury in the lung. AJR Am J Roentgenol 1988; 150:765-770.
    • (1988) AJR Am J Roentgenol , vol.150 , pp. 765-770
    • Ikezoe, J.1    Takashima, S.2    Morimoto, S.3
  • 10
    • 0021366383 scopus 로고
    • Radiation-induced pulmonary change: CT findings
    • Libshitz HI, Shuman LS. Radiation-induced pulmonary change: CT findings. J Comput Assist Tomogr 1984; 8:15-19.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 15-19
    • Libshitz, H.I.1    Shuman, L.S.2
  • 12
    • 0033629963 scopus 로고    scopus 로고
    • Unusual radiologic findings in the thorax after radiation therapy
    • Mesurolle B, Qanadli SD, Merad M, et al. Unusual radiologic findings in the thorax after radiation therapy. RadioGraphics 2000; 20:67-81.
    • (2000) RadioGraphics , vol.20 , pp. 67-81
    • Mesurolle, B.1    Qanadli, S.D.2    Merad, M.3
  • 13
    • 0020052212 scopus 로고
    • CT manifestations of radiation-induced change in chest tissue
    • Pagani JJ, Libshitz HI. CT manifestations of radiation-induced change in chest tissue. J Comput Assist Tomogr 1982; 6:243-248.
    • (1982) J Comput Assist Tomogr , vol.6 , pp. 243-248
    • Pagani, J.J.1    Libshitz, H.I.2
  • 14
    • 0033629335 scopus 로고    scopus 로고
    • Radiation-induced lung disease and the impact of radiation methods on imaging features
    • Park KJ, Chung JY, Chun MS, Suh JH. Radiation-induced lung disease and the impact of radiation methods on imaging features. RadioGraphics 2000; 20:83-98.
    • (2000) RadioGraphics , vol.20 , pp. 83-98
    • Park, K.J.1    Chung, J.Y.2    Chun, M.S.3    Suh, J.H.4
  • 15
    • 0034594628 scopus 로고    scopus 로고
    • New guidelines to evaluate the response to treatment in solid tumors: European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada
    • Therasse P, Arbuck SG, Eisenhauer EA, et al. New guidelines to evaluate the response to treatment in solid tumors: European Organization for Research and Treatment of Cancer, National Cancer Institute of the United States, National Cancer Institute of Canada. J Natl Cancer Inst 2000; 92:205-216.
    • (2000) J Natl Cancer Inst , vol.92 , pp. 205-216
    • Therasse, P.1    Arbuck, S.G.2    Eisenhauer, E.A.3
  • 16
    • 0034176245 scopus 로고    scopus 로고
    • Common toxicity criteria: Version 2.0 an improved reference for grading the acute effects of cancer treatment-impact on radiotherapy
    • Trotti A, Byhardt R, Stetz J, et al. Common toxicity criteria: version 2.0 an improved reference for grading the acute effects of cancer treatment-impact on radiotherapy. Int J Radiat Oncol Biol Phys 2000; 47:13-47.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 13-47
    • Trotti, A.1    Byhardt, R.2    Stetz, J.3
  • 17
    • 0029014655 scopus 로고
    • Detecting recurrent or residual lung cancer with FDG-PET
    • Inoue T, Kim EE, Komaki R, et al. Detecting recurrent or residual lung cancer with FDG-PET. J Nucl Med 1995; 36:788-793.
    • (1995) J Nucl Med , vol.36 , pp. 788-793
    • Inoue, T.1    Kim, E.E.2    Komaki, R.3
  • 18
    • 0028325906 scopus 로고
    • Persistent or recurrent bronchogenic carcinoma: Detection with PET and 2-[F-18]-2-deoxy-D-glucose
    • Patz EF Jr, Lowe VJ, Hoffman JM, Paine SS, Harris LK, Goodman PC. Persistent or recurrent bronchogenic carcinoma: detection with PET and 2-[F-18]-2-deoxy-D-glucose. Radiology 1994; 191:379-382.
    • (1994) Radiology , vol.191 , pp. 379-382
    • Patz Jr., E.F.1    Lowe, V.J.2    Hoffman, J.M.3    Paine, S.S.4    Harris, L.K.5    Goodman, P.C.6
  • 19
    • 0035708631 scopus 로고    scopus 로고
    • From tumor biology to clinical PET: A review of positron emission tomography (PET) in oncology
    • Kubota K. From tumor biology to clinical PET: a review of positron emission tomography (PET) in oncology. Ann Nucl Med 2001; 15:471-486.
    • (2001) Ann Nucl Med , vol.15 , pp. 471-486
    • Kubota, K.1
  • 22
    • 0032840324 scopus 로고    scopus 로고
    • Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)
    • Graham MV, Purdy JA, Emami B, et al. Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC). Int J Radiat Oncol Biol Phys 1999; 45:323-329.
    • (1999) Int J Radiat Oncol Biol Phys , vol.45 , pp. 323-329
    • Graham, M.V.1    Purdy, J.A.2    Emami, B.3
  • 24
    • 0034176902 scopus 로고    scopus 로고
    • Late rectal toxicity after conformal radiotherapy of prostate cancer (I): Multivariate analysis and dose-response
    • Skwarchuk MW, Jackson A, Zelefsky MJ, et al. Late rectal toxicity after conformal radiotherapy of prostate cancer (I): multivariate analysis and dose-response. Int J Radiat Oncol Biol Phys 2000; 47:103-113.
    • (2000) Int J Radiat Oncol Biol Phys , vol.47 , pp. 103-113
    • Skwarchuk, M.W.1    Jackson, A.2    Zelefsky, M.J.3
  • 25
    • 0035283676 scopus 로고    scopus 로고
    • Late rectal bleeding after conformal radiotherapy of prostate cancer. II. Volume effects and dose-volume histograms
    • Jackson A, Skwarchuk MW, Zelefsky MJ, et al. Late rectal bleeding after conformal radiotherapy of prostate cancer. II. Volume effects and dose-volume histograms. Int J Radiat Oncol Biol Phys 2001; 49: 685-698.
    • (2001) Int J Radiat Oncol Biol Phys , vol.49 , pp. 685-698
    • Jackson, A.1    Skwarchuk, M.W.2    Zelefsky, M.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.