메뉴 건너뛰기




Volumn 39, Issue 1, 2004, Pages 13-19

Gauging Effective Spatial Resolution in Multirow Helical Cardiac Computed Tomography with a Dynamic Phantom

Author keywords

Artifact; Computed tomography (CT); Coronary vessels; Experimental studies; Heart; Image quality

Indexed keywords

TUNGSTEN;

EID: 0347419460     PISSN: 00209996     EISSN: None     Source Type: Journal    
DOI: 10.1097/01.rli.0000091848.80376.d5     Document Type: Article
Times cited : (4)

References (18)
  • 1
    • 0033180517 scopus 로고    scopus 로고
    • Subsecond multi-slice computed tomography: Basics and applications
    • Klingenbeck-Regn K, Schaller S, Flohr T, et al. Subsecond multi-slice computed tomography: basics and applications. Eur J Radiol. 1999;31:110-124.
    • (1999) Eur J Radiol , vol.31 , pp. 110-124
    • Klingenbeck-Regn, K.1    Schaller, S.2    Flohr, T.3
  • 2
    • 0032924568 scopus 로고    scopus 로고
    • Multi-slice helical CT: Scan and reconstruction
    • Hu H. Multi-slice helical CT: scan and reconstruction. Med Phys. 1999;26:5-18.
    • (1999) Med Phys , vol.26 , pp. 5-18
    • Hu, H.1
  • 3
    • 0034610434 scopus 로고    scopus 로고
    • Noninvasive coronary angiography by retrospectively ECG-gated multislice CT
    • Achenbach S, Ulzheimer S, Baum U, et al. Noninvasive coronary angiography by retrospectively ECG-gated multislice CT. Circulation. 2000;0102:2823-2828.
    • (2000) Circulation , vol.102 , pp. 2823-2828
    • Achenbach, S.1    Ulzheimer, S.2    Baum, U.3
  • 4
    • 0033753104 scopus 로고    scopus 로고
    • Cardiac imaging by means of electrocardiographically gated multislice spiral CT: Initial experiences
    • Ohnesorge B, Flohr T, Becker C, et al. Cardiac imaging by means of electrocardiographically gated multislice spiral CT: initial experiences. Radiology. 2000;217:564-571.
    • (2000) Radiology , vol.217 , pp. 564-571
    • Ohnesorge, B.1    Flohr, T.2    Becker, C.3
  • 5
    • 0035941737 scopus 로고    scopus 로고
    • Coronary angiography with multi-slice computed tomography
    • Nieman K, Oudkerk M, Rensing BJ, et al. Coronary angiography with multi-slice computed tomography. Lancet. 2001;357:599-603.
    • (2001) Lancet , vol.357 , pp. 599-603
    • Nieman, K.1    Oudkerk, M.2    Rensing, B.J.3
  • 6
    • 0035967495 scopus 로고    scopus 로고
    • Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographicallygated, multislice spiral computed tomography
    • Achenbach S, Giesler T, Ropers D, et al. Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographicallygated, multislice spiral computed tomography. Circulation. 2001;103:2535-2538.
    • (2001) Circulation , vol.103 , pp. 2535-2538
    • Achenbach, S.1    Giesler, T.2    Ropers, D.3
  • 7
    • 0036597157 scopus 로고    scopus 로고
    • Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT
    • Ohnesorge B, Flohr T, Fischbach R, et al. Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT. Eur Radiol. 2002;12:1532-1540.
    • (2002) Eur Radiol , vol.12 , pp. 1532-1540
    • Ohnesorge, B.1    Flohr, T.2    Fischbach, R.3
  • 8
    • 0014557223 scopus 로고
    • Point spread function and modulation transfer function
    • Rossmann K. Point spread function and modulation transfer function. Radiology. 1969;93:257-272.
    • (1969) Radiology , vol.93 , pp. 257-272
    • Rossmann, K.1
  • 9
    • 0022590576 scopus 로고
    • Spatial resolution of computed tomographic images
    • Assimakopulos PA, Boyd DP, Jaschke W, et al. Spatial resolution of computed tomographic images. Invest Radiol. 1986;21:260-271.
    • (1986) Invest Radiol , vol.21 , pp. 260-271
    • Assimakopulos, P.A.1    Boyd, D.P.2    Jaschke, W.3
  • 10
    • 0017360990 scopus 로고
    • The measurement of observer agreement for categorical data
    • Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174.
    • (1977) Biometrics , vol.33 , pp. 159-174
    • Landis, J.R.1    Koch, G.G.2
  • 12
    • 0034867726 scopus 로고    scopus 로고
    • ECG-gated reconstructed multi-detector row CT coronary angiography: Effect of varying trigger delay on image quality
    • Hong C, Becker CR, Huber A, et al. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology. 2001;220:712-717.
    • (2001) Radiology , vol.220 , pp. 712-717
    • Hong, C.1    Becker, C.R.2    Huber, A.3
  • 13
    • 0036210278 scopus 로고    scopus 로고
    • Techniques for the detection of coronary atherosclerosis: Multi-detector row CT coronary angiography
    • Vogl TJ, Abolmaali ND, Diebold T, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology. 2002;223:212-220.
    • (2002) Radiology , vol.223 , pp. 212-220
    • Vogl, T.J.1    Abolmaali, N.D.2    Diebold, T.3
  • 14
    • 0033876932 scopus 로고    scopus 로고
    • In-plane coronary arterial motion velocity: Measurement with electron-beam CT
    • Achenbach S, Ropers D, Holle J, et al. In-plane coronary arterial motion velocity: measurement with electron-beam CT. Radiology. 2000;216: 457-463.
    • (2000) Radiology , vol.216 , pp. 457-463
    • Achenbach, S.1    Ropers, D.2    Holle, J.3
  • 15
    • 0035191747 scopus 로고    scopus 로고
    • Coronary arteries: Retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window
    • Kopp AF, Schroeder S, Kuettner A, et al. Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology. 2001;221:683-688.
    • (2001) Radiology , vol.221 , pp. 683-688
    • Kopp, A.F.1    Schroeder, S.2    Kuettner, A.3
  • 16
  • 17
    • 0038078538 scopus 로고    scopus 로고
    • Evaluation of retrospective multisector and half scan ECG-gated multi-detector cardiac CT protocols with moving phantom
    • Wicky S, Rosol M, Hamberg LM, et al. Evaluation of retrospective multisector and half scan ECG-gated multi-detector cardiac CT protocols with moving phantom. J Comput Assist Tomogr. 2003;27:392-398.
    • (2003) J Comput Assist Tomogr , vol.27 , pp. 392-398
    • Wicky, S.1    Rosol, M.2    Hamberg, L.M.3
  • 18
    • 0036153980 scopus 로고    scopus 로고
    • Comparison of electron-beam and ungated helical CT in detecting coronary arterial calcification by using a working heart phantom and artificial coronary arteries
    • Hopper KD, Strollo DC, Mauger DT. Comparison of electron-beam and ungated helical CT in detecting coronary arterial calcification by using a working heart phantom and artificial coronary arteries. Radiology. 2002;222:474-482.
    • (2002) Radiology , vol.222 , pp. 474-482
    • Hopper, K.D.1    Strollo, D.C.2    Mauger, D.T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.