1
-
-
0026224185
-
Pump Performance and Hemolytic Property of a Vibration Pump as a Ventricular Assist Device
-
in Japanese
-
Aoki, M., Hashimoto, H., Nitta, S., Sonobe, T., and Hiyama, H., 1991, "Pump Performance and Hemolytic Property of a Vibration Pump as a Ventricular Assist Device," Transactions of the Japan Society of Mechanical Engineers, Vol. 57, pp. 3123-3127 (in Japanese).
-
(1991)
Transactions of the Japan Society of Mechanical Engineers
, vol.57
, pp. 3123-3127
-
-
Aoki, M.1
Hashimoto, H.2
Nitta, S.3
Sonobe, T.4
Hiyama, H.5
-
3
-
-
0028028921
-
Development of Prototype Pump Using a Vibrating Pipe with a Valve
-
ASME
-
Hashimoto, H., Hiyama, H., and Sato, R., 1994, "Development of Prototype Pump Using a Vibrating Pipe With a Valve," ASME Journal of Fluids Engineering, Vol. 116, pp. 741-745.
-
(1994)
Journal of Fluids Engineering
, vol.116
, pp. 741-745
-
-
Hashimoto, H.1
Hiyama, H.2
Sato, R.3
-
4
-
-
12844285039
-
-
Private communication
-
Hashimoto, H., and Nitta, S., 1992 (Private communication).
-
(1992)
-
-
Hashimoto, H.1
Nitta, S.2
-
5
-
-
0028031232
-
Carotid Arterial Impedance during Oscillated Blood Flow
-
Kobayashi, S., Nitta, S., Yambe, T., Naganuma, S., Tanaka, M., Kasai, T., and Hashimoto, H., 1994, "Carotid Arterial Impedance During Oscillated Blood Flow," Artificial Organs, Vol. 18, pp. 627-632.
-
(1994)
Artificial Organs
, vol.18
, pp. 627-632
-
-
Kobayashi, S.1
Nitta, S.2
Yambe, T.3
Naganuma, S.4
Tanaka, M.5
Kasai, T.6
Hashimoto, H.7
-
6
-
-
0030806432
-
Hemolysis Test of Disposable Type Vibrating Flow Pump
-
Kobayashi, S., Nitta, S., Yambe, T., Sonobe, T., Naganuma, S., and Hashimoto, H., 1997, "Hemolysis Test of Disposable Type Vibrating Flow Pump," Artificial Organs, Vol. 21, pp. 691-693.
-
(1997)
Artificial Organs
, vol.21
, pp. 691-693
-
-
Kobayashi, S.1
Nitta, S.2
Yambe, T.3
Sonobe, T.4
Naganuma, S.5
Hashimoto, H.6
-
7
-
-
0025315020
-
The Development and Evaluation of Vibrating Electro-Magnetic Pump for the Artificial Heart
-
in Japanese
-
Sonobe, T., Nitta, S., Katahira, Y., Yambe, T., Naganuma, S., Akiho, H., Hayashi H., Miura, M., Satoh, N., Mohri, H., Hiyama, H., Hashimoto, H., and Tanaka, M., 1990, "The Development and Evaluation of Vibrating Electro-Magnetic Pump for the Artificial Heart," Japanese Journal of Artificial Organs, Vol. 19, pp. 113-116 (in Japanese).
-
(1990)
Japanese Journal of Artificial Organs
, vol.19
, pp. 113-116
-
-
Sonobe, T.1
Nitta, S.2
Katahira, Y.3
Yambe, T.4
Naganuma, S.5
Akiho, H.6
Hayashi, H.7
Miura, M.8
Satoh, N.9
Mohri, H.10
Hiyama, H.11
Hashimoto, H.12
Tanaka, M.13
-
8
-
-
12844277053
-
An Evaluation of Hemolysis in the Vibrating Electro-Magnetic Pump
-
in Japanese
-
Sonobe, T., Nitta, S., Katahira, Y., Yambe, T., Naganuma, S., Akiho, H., Hayashi H., Kakinuma, Y., Tanaka, M., Miura, M., Satoh, N., Mohri, H., Hiyama, H., Aoki, M., Hashimoto, H., Endoh, E., and Hoshino, A., 1991, "An Evaluation of Hemolysis in the Vibrating Electro-Magnetic Pump," Japanese Journal of Medical Electronics and Biological Engineering, Vol. 29, p. 304 (in Japanese).
-
(1991)
Japanese Journal of Medical Electronics and Biological Engineering
, vol.29
, pp. 304
-
-
Sonobe, T.1
Nitta, S.2
Katahira, Y.3
Yambe, T.4
Naganuma, S.5
Akiho, H.6
Hayashi, H.7
Kakinuma, Y.8
Tanaka, M.9
Miura, M.10
Satoh, N.11
Mohri, H.12
Hiyama, H.13
Aoki, M.14
Hashimoto, H.15
Endoh, E.16
Hoshino, A.17
-
9
-
-
49549151238
-
Automatic Numerical Generation of Body-Fitted Curvilinear Coordinate System for Field Containing Any Number of Arbitrary Two-Dimensional Bodies
-
Thompson, J. F., Thames, F. C., and Mastin, C. W., 1974, "Automatic Numerical Generation of Body-Fitted Curvilinear Coordinate System for Field Containing Any Number of Arbitrary Two-Dimensional Bodies," Journal of Computational Physics, Vol. 15, pp. 299-319.
-
(1974)
Journal of Computational Physics
, vol.15
, pp. 299-319
-
-
Thompson, J.F.1
Thames, F.C.2
Mastin, C.W.3
|