메뉴 건너뛰기




Volumn 97, Issue 1, 2004, Pages 74-80

Improvements in the long-term stability of a LiCl dew-point sensor using cross-linked porous poly(vinyl alcohol) film

Author keywords

Cross linked porous PVA film; Humidity sensor; LiCl dew point sensor

Indexed keywords

CONDENSATION; CROSSLINKING; DIELECTRIC MATERIALS; FORMALDEHYDE; FOURIER TRANSFORM INFRARED SPECTROSCOPY; LITHIUM COMPOUNDS; MORPHOLOGY; POLYVINYL ALCOHOLS; POROUS MATERIALS; SCANNING ELECTRON MICROSCOPY;

EID: 0347020979     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2003.07.007     Document Type: Article
Times cited : (14)

References (13)
  • 1
    • 0033276729 scopus 로고    scopus 로고
    • Humidity sensors using chemically modified polymer thin films
    • Sakai Y., Matsuguchi M. Humidity sensors using chemically modified polymer thin films. Electrochemistry. 67:1999;950-956.
    • (1999) Electrochemistry , vol.67 , pp. 950-956
    • Sakai, Y.1    Matsuguchi, M.2
  • 2
    • 0030234081 scopus 로고    scopus 로고
    • Humidity sensors based on polymer thin films
    • Sakai Y., Sadaoka Y., Matsuguchi M. Humidity sensors based on polymer thin films. Sens. Actuators B. 35-36:1996;85-90.
    • (1996) Sens. Actuators B , vol.35-36 , pp. 85-90
    • Sakai, Y.1    Sadaoka, Y.2    Matsuguchi, M.3
  • 3
    • 0000453913 scopus 로고
    • Reliability and reproducibility of ceramic sensors. Part III. Humidity Sensors
    • Fagan J.G., Amarakoon V.R.W. Reliability and reproducibility of ceramic sensors. Part III. Humidity Sensors. Am. Ceram. Soc. Bull. 72:1993;119-130.
    • (1993) Am. Ceram. Soc. Bull. , vol.72 , pp. 119-130
    • Fagan, J.G.1    Amarakoon, V.R.W.2
  • 4
    • 58149325887 scopus 로고
    • Ceramic sensors for humidity detection: The state of the art and future developments
    • Traversa E. Ceramic sensors for humidity detection: the state of the art and future developments. Sens. Actuators B. 23:1995;135-156.
    • (1995) Sens. Actuators B , vol.23 , pp. 135-156
    • Traversa, E.1
  • 5
    • 0347804924 scopus 로고
    • Test and adaptation of the Foxboro dew-point recorder for weather observatory use
    • Conover J.H. Test and adaptation of the Foxboro dew-point recorder for weather observatory use. Bull. Am. Meteor. Soc. 31:1950;13-22.
    • (1950) Bull. Am. Meteor. Soc. , vol.31 , pp. 13-22
    • Conover, J.H.1
  • 6
    • 0346544650 scopus 로고
    • Measurement of atmospheric humidity up to 35 km
    • Btasefield C.J. Measurement of atmospheric humidity up to 35. km J. Meteor. 11:1954;412-416.
    • (1954) J. Meteor. , vol.11 , pp. 412-416
    • Btasefield, C.J.1
  • 7
    • 0242309926 scopus 로고
    • A new electrical hygrometer
    • White W.C. A new electrical hygrometer. Elect. Eng. 73:1954;1084-1087.
    • (1954) Elect. Eng. , vol.73 , pp. 1084-1087
    • White, W.C.1
  • 8
    • 0347804923 scopus 로고
    • Absolute and relative Feuchtebestimmunger mit dem lithium chloride-Feuchtmesser
    • Lineweg F. Absolute and relative Feuchtebestimmunger mit dem lithium chloride-Feuchtmesser. Siemens Z. 19(5-6):1955;S212-S218.
    • (1955) Siemens Z. , vol.19 , Issue.5-6
    • Lineweg, F.1
  • 9
    • 0347804919 scopus 로고
    • The mode of operation of saturation temperature hygrometers based on electrical detection of a salt-solution phase transition
    • Washington, DC, USA, 20-23 May
    • D.E. Nelson, E.J. Amdur, The mode of operation of saturation temperature hygrometers based on electrical detection of a salt-solution phase transition, in: Proceedings of the International Symposium on Humidity and Moisture, Washington, DC, USA, 20-23 May 1963, pp. 617-626.
    • (1963) Proceedings of the International Symposium on Humidity and Moisture , pp. 617-626
    • Nelson, D.E.1    Amdur, E.J.2
  • 10
    • 0018156306 scopus 로고
    • Recent developments in the self-heated lithium chloride dew point sensors
    • Heggemann R.H. Recent developments in the self-heated lithium chloride dew point sensors. Anal. Instrum. 16:1978;117-120.
    • (1978) Anal. Instrum. , vol.16 , pp. 117-120
    • Heggemann, R.H.1
  • 11
    • 0022512061 scopus 로고
    • The improvement of lithium chloride dew-point hygrometer for direct reading and controlling of relative humidity
    • Zhang X.Z., Hu X.Q. The improvement of lithium chloride dew-point hygrometer for direct reading and controlling of relative humidity. Environ. Int. 12:1986;471-474.
    • (1986) Environ. Int. , vol.12 , pp. 471-474
    • Zhang, X.Z.1    Hu, X.Q.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.