메뉴 건너뛰기




Volumn 175, Issue 12, 2003, Pages 1711-1719

Systematics of Imaging Artifacts in MRT Caused by Metallic Vascular Implants (Stents);Systematik der Artefakte Metallischer Gefäßprothesen (Stents) in der MRT

Author keywords

Artifacts; MR angiography; MR imaging; Stents

Indexed keywords

ALLOY; NITINOL; STAINLESS STEEL;

EID: 0346991913     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2003-45329     Document Type: Article
Times cited : (20)

References (25)
  • 1
    • 0026488607 scopus 로고
    • Intravascular stenting: From basic research to clinical application
    • Palmaz JC. Intravascular stenting: from basic research to clinical application. Cardiovasc Intervent Radiol 1992; 15: 279-284
    • (1992) Cardiovasc Intervent Radiol , vol.15 , pp. 279-284
    • Palmaz, J.C.1
  • 3
    • 0030068119 scopus 로고    scopus 로고
    • Aortic and iliac stenoses: Follow up results of stent placement after insufficient ballon angioplasty in 118 cases
    • Vorwerk D, Günther RW, Schürmann K, Wendt G. Aortic and iliac stenoses: follow up results of stent placement after insufficient ballon angioplasty in 118 cases. Radiology 1996; 198: 45-48
    • (1996) Radiology , vol.198 , pp. 45-48
    • Vorwerk, D.1    Günther, R.W.2    Schürmann, K.3    Wendt, G.4
  • 4
    • 0029845744 scopus 로고    scopus 로고
    • Coronary artery stenting: Indications and cost implications
    • Cohen EA, Schwartz L. Coronary artery stenting: indications and cost implications. Prog Cardiovasc Dis 1996; 39: 83-110
    • (1996) Prog Cardiovasc Dis , vol.39 , pp. 83-110
    • Cohen, E.A.1    Schwartz, L.2
  • 5
    • 0029848898 scopus 로고    scopus 로고
    • Contemporary stent designs: Technical considerations, complications, role of intravascular ultrasound, and anticoagulation
    • Pompa JJ, Lansky AJ, Ito S, Mintz GS, Leon MB. Contemporary stent designs: Technical considerations, complications, role of intravascular ultrasound, and anticoagulation. Therapy Prog Cardiovasc Diss 1996; 39: 111-128
    • (1996) Therapy Prog Cardiovasc Diss , vol.39 , pp. 111-128
    • Pompa, J.J.1    Lansky, A.J.2    Ito, S.3    Mintz, G.S.4    Leon, M.B.5
  • 6
    • 0013645822 scopus 로고    scopus 로고
    • Endovascular treatment of abdominal aortic aneurysms in Norway: The first 100 patients
    • Lundbom J, Hatlinghus S, Wirsching J, et al. Endovascular treatment of abdominal aortic aneurysms in Norway: the first 100 patients. Europ J Vasc Endovasc Surg 1999; 18: 506-509
    • (1999) Europ J Vasc Endovasc Surg , vol.18 , pp. 506-509
    • Lundbom, J.1    Hatlinghus, S.2    Wirsching, J.3
  • 7
    • 0028394295 scopus 로고
    • Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis
    • Lossef SV, Lutz RJ, Mundorf J, Barth KH. Comparison of mechanical deformation properties of metallic stents with use of stress-strain analysis. J Vasc Interv Radiol 1994; 5: 341-349
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 341-349
    • Lossef, S.V.1    Lutz, R.J.2    Mundorf, J.3    Barth, K.H.4
  • 8
    • 0032811088 scopus 로고    scopus 로고
    • Iliofemoral arterial occlusive disease: Contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement
    • Link J, Steffens JC, Brossmann J, Graessner J, Hacketal S, Heller M. Iliofemoral arterial occlusive disease: contrast-enhanced MR angiography for preinterventional evaluation and follow-up after stent placement. Radiology 1999; 212: 371-377
    • (1999) Radiology , vol.212 , pp. 371-377
    • Link, J.1    Steffens, J.C.2    Brossmann, J.3    Graessner, J.4    Hacketal, S.5    Heller, M.6
  • 11
    • 0027159714 scopus 로고
    • Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisited
    • Bakker CJG, Bhagwandien R, Meorland MA, Fuderer M. Susceptibility artifacts in 2DFT spin-echo and gradient-echo imaging: The cylinder model revisited. Magn Res Imag 1993; 11: 539-548
    • (1993) Magn Res Imag , vol.11 , pp. 539-548
    • Bakker, C.J.G.1    Bhagwandien, R.2    Meorland, M.A.3    Fuderer, M.4
  • 12
    • 0033818667 scopus 로고    scopus 로고
    • MR-imaging in the presence of vascular stents: A systematic assessment of artifact for various stents orientations, sequence types, and field strengths
    • Klemm T, Duda S, Machann J, Seekamp-Rahn K, Schnieder L, Claussen CD, Schick F. MR-imaging in the presence of vascular stents: a systematic assessment of artifact for various stents orientations, sequence types, and field strengths. J Magn Reson Imag 2000; 12: 606-615
    • (2000) J Magn Reson Imag , vol.12 , pp. 606-615
    • Klemm, T.1    Duda, S.2    Machann, J.3    Seekamp-Rahn, K.4    Schnieder, L.5    Claussen, C.D.6    Schick, F.7
  • 15
    • 0023762169 scopus 로고
    • Low-artifact intravascular devices: MR imaging evaluation
    • Teitelbaum GP, Ortega HV, Vinitsky S, et al. Low-artifact intravascular devices: MR imaging evaluation. Radiology 1988: 168: 713-719
    • (1988) Radiology , vol.168 , pp. 713-719
    • Teitelbaum, G.P.1    Ortega, H.V.2    Vinitsky, S.3
  • 16
    • 0023832613 scopus 로고
    • MR imaging artifacts, femoro-magnetism, and magnetic torque of intravascular filters, stems and coils
    • Teitelbaum GP, Bradley Jr WG, Klein BD. MR imaging artifacts, femoro-magnetism, and magnetic torque of intravascular filters, stems and coils. Radiology 1988; 166: 657-664
    • (1988) Radiology , vol.166 , pp. 657-664
    • Teitelbaum, G.P.1    Bradley Jr., W.G.2    Klein, B.D.3
  • 19
    • 0345298274 scopus 로고    scopus 로고
    • Plain and covered stent-grafts: In vitro evaluation of characteristics at three dimensional MR angiography
    • Hilfiker PR, Quick HH, Debatin JF. Plain and covered stent-grafts: in vitro evaluation of characteristics at three dimensional MR angiography. Radiology 1999; 211: 693-697
    • (1999) Radiology , vol.211 , pp. 693-697
    • Hilfiker, P.R.1    Quick, H.H.2    Debatin, J.F.3
  • 20
    • 0035107929 scopus 로고    scopus 로고
    • MR imaging of vascular stents: Effects of susceptibility, flow, and radiofrequency eddy currents
    • Bartels LW, Smits HF, Bakker CJ, Viergever MA. MR imaging of vascular stents: effects of susceptibility, flow, and radiofrequency eddy currents. J Vasc Interv Radiol 2001; 12 (3): 365-371
    • (2001) J Vasc Interv Radiol , vol.12 , Issue.3 , pp. 365-371
    • Bartels, L.W.1    Smits, H.F.2    Bakker, C.J.3    Viergever, M.A.4
  • 21
    • 0034543124 scopus 로고    scopus 로고
    • Stent appearance at contrast-enhanced MR angiography: In vitro examination with 14 stents
    • Lenhart M, Volk M, Manke C, Nitz WR, Strotzer M, Feuerbach S, Link J. Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents. Radiology 2000; 217 (1): 173-178
    • (2000) Radiology , vol.217 , Issue.1 , pp. 173-178
    • Lenhart, M.1    Volk, M.2    Manke, C.3    Nitz, W.R.4    Strotzer, M.5    Feuerbach, S.6    Link, J.7
  • 22
    • 0034520188 scopus 로고    scopus 로고
    • MR evaluation of stent patency: In vitro test of 22 metallic stents and the possibility of determining their patency by MR angiography
    • Meyer JM, Buecker A, Schuermann K, Ruebben A, Guenther RW. MR evaluation of stent patency: in vitro test of 22 metallic stents and the possibility of determining their patency by MR angiography. Invest Radiol 2000; 35 (12): 739-746
    • (2000) Invest Radiol , vol.35 , Issue.12 , pp. 739-746
    • Meyer, J.M.1    Buecker, A.2    Schuermann, K.3    Ruebben, A.4    Guenther, R.W.5
  • 23
    • 0029184004 scopus 로고
    • Nonsusceptibility artifacts due to metallic objects in MR imaging
    • Camacho CR, Plewes DB, Henkelman RM. Nonsusceptibility artifacts due to metallic objects in MR imaging. J Magn Reson Imaging 1995; 5 (1): 75-88
    • (1995) J Magn Reson Imaging , vol.5 , Issue.1 , pp. 75-88
    • Camacho, C.R.1    Plewes, D.B.2    Henkelman, R.M.3
  • 24
    • 0034752490 scopus 로고    scopus 로고
    • The active resonance imaging stent (AMRIS): Initial experimental in vivo results with locally amplified MR angiography and flow measurements
    • Kivelitz D, Wagner S, Hansel J, Schnorr J, Wetzler R, Busch M, Melzer A, Taupitz M, Hamm B. The active resonance imaging stent (AMRIS): initial experimental in vivo results with locally amplified MR angiography and flow measurements. Invest Radiol 2001; 36 (11): 625-631
    • (2001) Invest Radiol , vol.36 , Issue.11 , pp. 625-631
    • Kivelitz, D.1    Wagner, S.2    Hansel, J.3    Schnorr, J.4    Wetzler, R.5    Busch, M.6    Melzer, A.7    Taupitz, M.8    Hamm, B.9


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.