메뉴 건너뛰기




Volumn 8, Issue 4, 2002, Pages 342-346

Flow Cytometry for Rapid Determination of Number of Microbial Cells Grown on Fish

Author keywords

Bacteria; Cell numbers; Flow cytometry; Microbial cell; Seafood

Indexed keywords

BACTERIA (MICROORGANISMS); CEPHALOPODA; EQUUS CABALLUS; OCTOPUS; OCTOPUS VULGARIS;

EID: 0346346373     PISSN: 13446606     EISSN: None     Source Type: Journal    
DOI: 10.3136/fstr.8.342     Document Type: Article
Times cited : (3)

References (20)
  • 1
    • 0026460015 scopus 로고
    • Characterization of bacteria by multiparameter flow cytometry
    • Allman, R., Hann, A.C., Manchee, R. and Lloyd, D. (1992) Characterization of bacteria by multiparameter flow cytometry. J. Appl. Bacteriol., 73, 438-444.
    • (1992) J. Appl. Bacteriol. , vol.73 , pp. 438-444
    • Allman, R.1    Hann, A.C.2    Manchee, R.3    Lloyd, D.4
  • 2
    • 0030099461 scopus 로고    scopus 로고
    • Detection of antibodies to Staphylococcus aureus in water buffalo milk by flow cytometry
    • D'Apice, L., Fenizia, D., Capparelli, R., Scala, F. and Iannelli, D. (1996). Detection of antibodies to Staphylococcus aureus in water buffalo milk by flow cytometry. Res. Vet. Sci., 60, 179-181.
    • (1996) Res. Vet. Sci. , vol.60 , pp. 179-181
    • D'Apice, L.1    Fenizia, D.2    Capparelli, R.3    Scala, F.4    Iannelli, D.5
  • 3
    • 0026448028 scopus 로고
    • Rapid assessment of bacterial viability by flow cytometry
    • Diaper, J.P., Tither, K. and Edwards, C. (1992). Rapid assessment of bacterial viability by flow cytometry. Appl. Microbiol. Biotechnol., 38, 268-272.
    • (1992) Appl. Microbiol. Biotechnol. , vol.38 , pp. 268-272
    • Diaper, J.P.1    Tither, K.2    Edwards, C.3
  • 4
    • 0027982254 scopus 로고
    • The use of fluorogenic esters to detect viable bacteria by flow cytometry
    • Diaper, J.P. and Edwards, C. (1994). The use of fluorogenic esters to detect viable bacteria by flow cytometry. J. Appl. Bacteriol., 77, 221-228.
    • (1994) J. Appl. Bacteriol. , vol.77 , pp. 221-228
    • Diaper, J.P.1    Edwards, C.2
  • 5
    • 0022514505 scopus 로고
    • Method for flow cytometric detection of Listeria monocytogenes in milk
    • Donnelly, C.W. and Baigent, G.J. (1986). Method for flow cytometric detection of Listeria monocytogenes in milk. Appl. Environ. Microbiol., 52, 689-695.
    • (1986) Appl. Environ. Microbiol. , vol.52 , pp. 689-695
    • Donnelly, C.W.1    Baigent, G.J.2
  • 6
    • 0014792201 scopus 로고
    • A rapid, quantitative fluorescence assay for cell damage by cytotoxic antibodies
    • Edidin, M. (1970). A rapid, quantitative fluorescence assay for cell damage by cytotoxic antibodies. J. Immunol., 104, 1303-1306.
    • (1970) J. Immunol. , vol.104 , pp. 1303-1306
    • Edidin, M.1
  • 7
    • 0024799038 scopus 로고
    • Determination of microbial concentration with a piezoelectric gum sensor
    • Endo, H., Sode, K., Ogura, K., Ohya, K. and Karube, I. (1989). Determination of microbial concentration with a piezoelectric gum sensor. J. Biotechnol., 12, 307-316.
    • (1989) J. Biotechnol. , vol.12 , pp. 307-316
    • Endo, H.1    Sode, K.2    Ogura, K.3    Ohya, K.4    Karube, I.5
  • 8
    • 0000943942 scopus 로고    scopus 로고
    • Application of flow cytometry for rapid determination of cell numbers of viable bacteria
    • Endo, H., Nakayama, J., Hayashi, T. and Watanabe, E. (1997). Application of flow cytometry for rapid determination of cell numbers of viable bacteria. Fish. Sci., 63, 1024-1029.
    • (1997) Fish. Sci. , vol.63 , pp. 1024-1029
    • Endo, H.1    Nakayama, J.2    Hayashi, T.3    Watanabe, E.4
  • 10
    • 0039890158 scopus 로고    scopus 로고
    • Rapid enumeration of bacteria grown on surimi-based product by flow cytometry
    • Endo, H., Nagano, Y., Ren, H. and Hayashi, T. (2001). Rapid enumeration of bacteria grown on surimi-based product by flow cytometry. Fish. Sci., 67, 969-974.
    • (2001) Fish. Sci. , vol.67 , pp. 969-974
    • Endo, H.1    Nagano, Y.2    Ren, H.3    Hayashi, T.4
  • 11
    • 0034014086 scopus 로고    scopus 로고
    • A flow cytometry method for rapid detection and enumeration of total bacteria in milk
    • Gunasekera, T.S., Attfield, P.V. and Veal, D.A. (2000). A flow cytometry method for rapid detection and enumeration of total bacteria in milk. Appl. Environ. Microbiol., 66, 1228-1232.
    • (2000) Appl. Environ. Microbiol. , vol.66 , pp. 1228-1232
    • Gunasekera, T.S.1    Attfield, P.V.2    Veal, D.A.3
  • 12
    • 85010133979 scopus 로고
    • Development of biosensor for the determination of total viable bacteria cell count
    • Hoshi, M., Nishi, H., Hayashi, T., Okuzumi, M. and Watanabe, E. (1991). Development of biosensor for the determination of total viable bacteria cell count. Bull. Jpn. Soc. Sci. Fish., 57, 281-285.
    • (1991) Bull. Jpn. Soc. Sci. Fish. , vol.57 , pp. 281-285
    • Hoshi, M.1    Nishi, H.2    Hayashi, T.3    Okuzumi, M.4    Watanabe, E.5
  • 13
    • 0031037612 scopus 로고    scopus 로고
    • Viability of starved Pasteurella piscicida in seawater monitored by flow cytometry and the effect of antibiotics on its resuscitation
    • Magarinos, B., Romalde, J.L., Cid, A. and Toranzo, A.E. (1997). Viability of starved Pasteurella piscicida in seawater monitored by flow cytometry and the effect of antibiotics on its resuscitation. Lett. Appl. Microbiol., 24, 122-126.
    • (1997) Lett. Appl. Microbiol. , vol.24 , pp. 122-126
    • Magarinos, B.1    Romalde, J.L.2    Cid, A.3    Toranzo, A.E.4
  • 14
    • 0021412689 scopus 로고
    • Detection of microbial cells by cyclic voltammetry
    • Matsunaga, T. and Namba, Y. (1984). Detection of microbial cells by cyclic voltammetry. Anal. Chem., 56, 798-801.
    • (1984) Anal. Chem. , vol.56 , pp. 798-801
    • Matsunaga, T.1    Namba, Y.2
  • 15
    • 0025811024 scopus 로고
    • Preliminary of flow cytometry for detection of yeast in soft drinks
    • Pettipher, G.L. (1991). Preliminary of flow cytometry for detection of yeast in soft drinks. Lett. Appl. Microbiol., 12, 109-112.
    • (1991) Lett. Appl. Microbiol. , vol.12 , pp. 109-112
    • Pettipher, G.L.1
  • 16
    • 77956792677 scopus 로고
    • Viable counts and viability
    • Postgate, J.R. (1969). Viable counts and viability. Methods Microbiol., 1, 611-621.
    • (1969) Methods Microbiol. , vol.1 , pp. 611-621
    • Postgate, J.R.1
  • 17
    • 0024230738 scopus 로고
    • Development of an electrochemical method for the rapid determination of microbial concentration and evidence for the reaction mechanism
    • Ramsay, G. and Turner, A.P.F. (1988). Development of an electrochemical method for the rapid determination of microbial concentration and evidence for the reaction mechanism. Anal. Chim. Acta, 215, 61-69.
    • (1988) Anal. Chim. Acta , vol.215 , pp. 61-69
    • Ramsay, G.1    Turner, A.P.F.2
  • 18
    • 0032211563 scopus 로고    scopus 로고
    • Comparison of methods for determining the presence of Escherichia coli O157:H7 in apple juice
    • Tortorello, M.L., Reineke, K.F., Stewart, D.S. and Raybourne, R.B. (1998). Comparison of methods for determining the presence of Escherichia coli O157:H7 in apple juice. J. Food. Prot., 61, 1425-1430.
    • (1998) J. Food. Prot. , vol.61 , pp. 1425-1430
    • Tortorello, M.L.1    Reineke, K.F.2    Stewart, D.S.3    Raybourne, R.B.4
  • 19
    • 0023119664 scopus 로고
    • Lysostaphin lysis procedure for detection of Staphylococcus aureus by the firefly bioluminescent ATP method
    • Tuncan, E.U. and Martin, S.E. (1987). Lysostaphin lysis procedure for detection of Staphylococcus aureus by the firefly bioluminescent ATP method. Appl. Environ. Microbiol. 53, 88-91.
    • (1987) Appl. Environ. Microbiol. , vol.53 , pp. 88-91
    • Tuncan, E.U.1    Martin, S.E.2
  • 20
    • 0024406017 scopus 로고
    • Determination of biomass by ultrasonic measurements
    • Zips, A. and Faust, U. (1989). Determination of biomass by ultrasonic measurements. Appl. Environ. Microbiol., 55, 1801-1807.
    • (1989) Appl. Environ. Microbiol. , vol.55 , pp. 1801-1807
    • Zips, A.1    Faust, U.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.