메뉴 건너뛰기




Volumn 17, Issue 6, 2003, Pages 201-208

New Homogeneous HDL-Cholesterol Assay Without the Influence of High TG Sample Using the Selective Detergent to Lipoproteins

Author keywords

HDL cholesterol; Homogeneous assay; Hypertriglyceridemia; Selective inhibition

Indexed keywords

CYCLODEXTRIN; DETERGENT; ENZYME; HIGH DENSITY LIPOPROTEIN CHOLESTEROL; LIPOPROTEIN; MACROGOL; TRIACYLGLYCEROL;

EID: 0346328429     PISSN: 08878013     EISSN: None     Source Type: Journal    
DOI: 10.1002/jcla.10101     Document Type: Article
Times cited : (12)

References (14)
  • 1
    • 0016433018 scopus 로고
    • Plasma high density lipoprotein contration and development of ischemic heart disease
    • Miller GJ, Miller NE. Plasma high density lipoprotein contration and development of ischemic heart disease. Lancet 1975;1:16-23.
    • (1975) Lancet , vol.1 , pp. 16-23
    • Miller, G.J.1    Miller, N.E.2
  • 2
    • 0017384270 scopus 로고
    • High density lipoprotein as a protective factor against coronary heart disease
    • Gordon T, Castelli WP, Hjortland MC, Kannel WB, Dawber TR. High density lipoprotein as a protective factor against coronary heart disease. Am J Med 1977;62:707-714.
    • (1977) Am J Med , vol.62 , pp. 707-714
    • Gordon, T.1    Castelli, W.P.2    Hjortland, M.C.3    Kannel, W.B.4    Dawber, T.R.5
  • 3
    • 0000161902 scopus 로고
    • Second report of the expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (Adult Treatment Panel II)
    • National Cholesterol Education Program. Second report of the expert panel on detection, evaluation, and treatment of high blood cholesterol in adults (Adult Treatment Panel II). Circulation 1994;89:1330-1445.
    • (1994) Circulation , vol.89 , pp. 1330-1445
  • 4
    • 0029878161 scopus 로고    scopus 로고
    • Three routine methods for measuring high-density lipoprotein cholesterol compared with the reference method
    • Harris N, Golpchian V, Rifai N. Three routine methods for measuring high-density lipoprotein cholesterol compared with the reference method. Clin Chem 1996;42:738-743.
    • (1996) Clin Chem , vol.42 , pp. 738-743
    • Harris, N.1    Golpchian, V.2    Rifai, N.3
  • 5
    • 0028939982 scopus 로고
    • Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol modified enzymes and sulfated α-cyclodextrin
    • Sugiuchi H, Uji Y, Okabe H, et al. Direct measurement of high-density lipoprotein cholesterol in serum with polyethylene glycol modified enzymes and sulfated α-cyclodextrin. Clin Chem 1995;41:717-723.
    • (1995) Clin Chem , vol.41 , pp. 717-723
    • Sugiuchi, H.1    Uji, Y.2    Okabe, H.3
  • 6
    • 0030912685 scopus 로고    scopus 로고
    • Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol
    • Huang YC, Kao JT, Tsai KS. Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol. Clin Chem 1997;43:1048-1055.
    • (1997) Clin Chem , vol.43 , pp. 1048-1055
    • Huang, Y.C.1    Kao, J.T.2    Tsai, K.S.3
  • 7
    • 0030773370 scopus 로고    scopus 로고
    • Evaluation of precipitation and direct methods for HDL-cholesterol assay by HPLC
    • Okazaki M, Sasamoto K, Muramatsu T, Hosaki S. Evaluation of precipitation and direct methods for HDL-cholesterol assay by HPLC. Clin Chem 1997;43:1885-1890.
    • (1997) Clin Chem , vol.43 , pp. 1885-1890
    • Okazaki, M.1    Sasamoto, K.2    Muramatsu, T.3    Hosaki, S.4
  • 9
    • 0031747464 scopus 로고    scopus 로고
    • Evaluation of homogeneous assay for high-density lipoprotein cholesterol: Limitations in patients with cardiovascular, renal, and hepatic disorders
    • Simo JM, Isabel C, Natalia FJ, Jorge J, Jordi C. Evaluation of homogeneous assay for high-density lipoprotein cholesterol: limitations in patients with cardiovascular, renal, and hepatic disorders. Clin Chem 1998;44:1233-1241.
    • (1998) Clin Chem , vol.44 , pp. 1233-1241
    • Simo, J.M.1    Isabel, C.2    Natalia, F.J.3    Jorge, J.4    Jordi, C.5
  • 10
    • 15444349654 scopus 로고    scopus 로고
    • Reference standardization and triglyceride interference of a new homogeneous HDL-cholesterol assay compared with a former chemical precipitation assay
    • Cobbaert C, Louwerens Z, Ferruccio C, et al. Reference standardization and triglyceride interference of a new homogeneous HDL-cholesterol assay compared with a former chemical precipitation assay. Clin Chem 1998;44:779-789.
    • (1998) Clin Chem , vol.44 , pp. 779-789
    • Cobbaert, C.1    Louwerens, Z.2    Ferruccio, C.3
  • 11
    • 0031804041 scopus 로고    scopus 로고
    • Assessment of interlaboratory performance in external proficiency testing programs with a direct HDL-cholesterol assay
    • Rifai N, Thomas G, Elizabeth I, et al. Assessment of interlaboratory performance in external proficiency testing programs with a direct HDL-cholesterol assay. Clin Chem 1998;44:1452-1458.
    • (1998) Clin Chem , vol.44 , pp. 1452-1458
    • Rifai, N.1    Thomas, G.2    Elizabeth, I.3
  • 12
    • 0028970546 scopus 로고
    • National Cholesterol Education Program recommendations for measurement of low-density lipoprotein cholesterol: Executive summary
    • The National Cholesterol Education Program Working Group on Lipoprotein Measurement
    • Bachorik PS, Ross JW. National Cholesterol Education Program recommendations for measurement of low-density lipoprotein cholesterol: executive summary. The National Cholesterol Education Program Working Group on Lipoprotein Measurement. Clin Chem 1995;41:1414-1420.
    • (1995) Clin Chem , vol.41 , pp. 1414-1420
    • Bachorik, P.S.1    Ross, J.W.2
  • 13
  • 14
    • 0017581614 scopus 로고
    • Unusual serum lipoprotein abnormality induced by the vehicle of miconazole
    • Bagnarello AG, Lewis LA, McHenry MC, et al. Unusual serum lipoprotein abnormality induced by the vehicle of miconazole. N Engl J Med 1977;296:497-499.
    • (1977) N Engl J Med , vol.296 , pp. 497-499
    • Bagnarello, A.G.1    Lewis, L.A.2    McHenry, M.C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.