메뉴 건너뛰기




Volumn 8, Issue 6, 2003, Pages 796-801

Intramedullary nailing of the femur with an inflatable self-locking nail: Comparison with locked nailing

Author keywords

Expandable; Intramedullary nailing; Self locking; Unreamed

Indexed keywords

ADULT; AGED; ARTICLE; BLOOD TRANSFUSION; BONE NAIL; CLINICAL ARTICLE; DIAPHYSIS; FEMALE; FEMUR FRACTURE; FEMUR SHAFT; FRACTURE FIXATION; HOSPITALIZATION; HUMAN; INTERMETHOD COMPARISON; INTRAMEDULLARY NAILING; IONIZING RADIATION; MALE; OPERATION DURATION; RADIATION EXPOSURE; SURGICAL TECHNIQUE;

EID: 0346251159     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00776-003-0709-8     Document Type: Article
Times cited : (41)

References (29)
  • 1
    • 85119088735 scopus 로고
    • Comparison of functional bracing and intramedullary nailing in the treatment of displaced tibial shaft fractures
    • Alho A, Benterud JG, Hogevold HE, et al. Comparison of functional bracing and intramedullary nailing in the treatment of displaced tibial shaft fractures. Clin Orthop 1990;227:243-50.
    • (1990) Clin Orthop , vol.227 , pp. 243-250
    • Alho, A.1    Benterud, J.G.2    Hogevold, H.E.3
  • 2
    • 0029059573 scopus 로고
    • A comparison of reamed and unreamed nailing of the tibia
    • Anglen JO, Blue JM. A comparison of reamed and unreamed nailing of the tibia. J Trauma 1995;39:351-5.
    • (1995) J Trauma , vol.39 , pp. 351-355
    • Anglen, J.O.1    Blue, J.M.2
  • 3
    • 0038421595 scopus 로고
    • Locked intramedullary nailing for femoral and tibial fractures with comminution or bone loss
    • Paper 60
    • Beck G. Locked intramedullary nailing for femoral and tibial fractures with comminution or bone loss. Presented at the American Association of Orthopedic Surgeons annual meeting, 1985. Paper 60.
    • (1985) American Association of Orthopedic Surgeons Annual Meeting
    • Beck, G.1
  • 5
    • 0023923819 scopus 로고
    • Intramedullary locking nails in the management of femoral shaft fractures
    • Christie J, Court-Brown C, Kinninmonth AW, et al. Intramedullary locking nails in the management of femoral shaft fractures. J Bone Joint Surg Br 1988;70:206-10.
    • (1988) J Bone Joint Surg Br , vol.70 , pp. 206-210
    • Christie, J.1    Court-Brown, C.2    Kinninmonth, A.W.3
  • 7
    • 0029898182 scopus 로고    scopus 로고
    • Reamed or unreamed nailing for closed tibial fractures: A prospective study in Tscherne C1 fractures
    • Court-Brown CM, Will E, Christie J, et al. Reamed or unreamed nailing for closed tibial fractures: a prospective study in Tscherne C1 fractures. J Bone Joint Surg Br 1996;78:580-3.
    • (1996) J Bone Joint Surg Br , vol.78 , pp. 580-583
    • Court-Brown, C.M.1    Will, E.2    Christie, J.3
  • 8
    • 0028968994 scopus 로고
    • Contaminated fractures of the tibia: A comparison of treatment modalities in an animal model
    • Curtis MJ, Brown PR, Dick JD, et al. Contaminated fractures of the tibia: a comparison of treatment modalities in an animal model. J Orthop Res 1995;13:286-95.
    • (1995) J Orthop Res , vol.13 , pp. 286-295
    • Curtis, M.J.1    Brown, P.R.2    Dick, J.D.3
  • 9
    • 0347683605 scopus 로고    scopus 로고
    • Prospective, surgeon randomized study comparing reamed versus unreamed intramedullary nailing for the treatment of unstable closed and open diaphyseal fractures
    • New Orleans
    • Finkemeier C, Kyle RF, Schmidt AH, et al. Prospective, surgeon randomized study comparing reamed versus unreamed intramedullary nailing for the treatment of unstable closed and open diaphyseal fractures. In: Proceedings of the 65th annual meeting of the American Academy of Orthopaedic Surgeons, 1998, New Orleans.
    • (1998) Proceedings of the 65th Annual Meeting of the American Academy of Orthopaedic Surgeons
    • Finkemeier, C.1    Kyle, R.F.2    Schmidt, A.H.3
  • 10
    • 0036944769 scopus 로고    scopus 로고
    • An expandable nailing system for the management of pathological humerus fractures
    • Franck WM, Olivieri M, Jannasch O, et al. An expandable nailing system for the management of pathological humerus fractures. Arch Orthop Trauma Surg 2002;122:400-5.
    • (2002) Arch Orthop Trauma Surg , vol.122 , pp. 400-405
    • Franck, W.M.1    Olivieri, M.2    Jannasch, O.3
  • 11
    • 0038463579 scopus 로고    scopus 로고
    • Expandable nail system for osteoporotic humeral shaft fractures: Preliminary results
    • Franck WM, Olivieri M, Jannasch O, et al. Expandable nail system for osteoporotic humeral shaft fractures: preliminary results. J Trauma 2003;54:1152-8.
    • (2003) J Trauma , vol.54 , pp. 1152-1158
    • Franck, W.M.1    Olivieri, M.2    Jannasch, O.3
  • 12
    • 0027314356 scopus 로고
    • Acute effects of intramedullary reaming on bone blood flow in rats
    • Grundnes O, Reikeras O. Acute effects of intramedullary reaming on bone blood flow in rats. Acta Orthop Scand 1993;64:203-6.
    • (1993) Acta Orthop Scand , vol.64 , pp. 203-206
    • Grundnes, O.1    Reikeras, O.2
  • 13
    • 0029016876 scopus 로고
    • Intramedullary nailing and pulmonary embolism: Does unreamed nailing prevent embolization? An in vitro study in rabbits
    • Heim D, Regazzoni P, Tsakiris DA, et al. Intramedullary nailing and pulmonary embolism: does unreamed nailing prevent embolization? An in vitro study in rabbits. J Trauma 1995;38:899-906.
    • (1995) J Trauma , vol.38 , pp. 899-906
    • Heim, D.1    Regazzoni, P.2    Tsakiris, D.A.3
  • 14
    • 0025312898 scopus 로고
    • Locked intramedullary nailing for recent lower limb fractures
    • Hindley CJ, Evans RA, Holt EM, et al. Locked intramedullary nailing for recent lower limb fractures. Injury 1990;21:239-44.
    • (1990) Injury , vol.21 , pp. 239-244
    • Hindley, C.J.1    Evans, R.A.2    Holt, E.M.3
  • 15
    • 0026505710 scopus 로고
    • Ionising radiation and the orthopaedic surgeon
    • Hynes DE, Conere T, Mee MB, et al. Ionising radiation and the orthopaedic surgeon. J Bone Joint Surg Br 1992;74:332-4.
    • (1992) J Bone Joint Surg Br , vol.74 , pp. 332-334
    • Hynes, D.E.1    Conere, T.2    Mee, M.B.3
  • 16
    • 0021885423 scopus 로고
    • Closed locked intramedullary nailing: Its application to comminuted fractures of the femur
    • Kempf I, Grosse A, Beck G. Closed locked intramedullary nailing: its application to comminuted fractures of the femur. J Bone Joint Surg Am 1985;67:709-20.
    • (1985) J Bone Joint Surg Am , vol.67 , pp. 709-720
    • Kempf, I.1    Grosse, A.2    Beck, G.3
  • 17
    • 0023026056 scopus 로고
    • Locked intramedullary nailing: Its application to femoral and tibial axial, rotational, lengthening, and shortening osteotomies
    • Kempf I, Grosse A, Abalo C. Locked intramedullary nailing: its application to femoral and tibial axial, rotational, lengthening, and shortening osteotomies. Clin Orthop 1986;212:165-73.
    • (1986) Clin Orthop , vol.212 , pp. 165-173
    • Kempf, I.1    Grosse, A.2    Abalo, C.3
  • 18
    • 0015459942 scopus 로고
    • Dynamic and static locking of the intramedullary nail
    • Klemm K, Schellmann WD. Dynamic and static locking of the intramedullary nail. Monatsschr Unfallheilkd 1972;75:568-75.
    • (1972) Monatsschr Unfallheilkd , vol.75 , pp. 568-575
    • Klemm, K.1    Schellmann, W.D.2
  • 19
    • 0014379682 scopus 로고
    • Intramedullary nailing of comminuted fractures
    • Kuntscher G. Intramedullary nailing of comminuted fractures. Arch Chir 1968;322:1063-9.
    • (1968) Arch Chir , vol.322 , pp. 1063-1069
    • Kuntscher, G.1
  • 20
    • 0347285836 scopus 로고    scopus 로고
    • Preliminary clinical and radiographic results with the Fixion™ intramedullary nail: An inflatable self-locking system for long bone fractures
    • Lepore S, Capuano N, Lepore L, et al. Preliminary clinical and radiographic results with the Fixion™ intramedullary nail: an inflatable self-locking system for long bone fractures. J Orthop Traumatol 2000;3:135-40.
    • (2000) J Orthop Traumatol , vol.3 , pp. 135-140
    • Lepore, S.1    Capuano, N.2    Lepore, L.3
  • 21
    • 0023278854 scopus 로고
    • Radiation exposure to the surgeon during closed interlocking intramedullary nailing
    • Levin PE, Schoen RW, Browner BD. Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg Am 1987;69:761-6.
    • (1987) J Bone Joint Surg Am , vol.69 , pp. 761-766
    • Levin, P.E.1    Schoen, R.W.2    Browner, B.D.3
  • 23
    • 0142152922 scopus 로고    scopus 로고
    • The fixion nail in the lower limb: Preliminary results
    • Pascarella R, Nasta G, Nicolini M, et al. The fixion nail in the lower limb: preliminary results. Chir Organi Mov 2002;87:169-74.
    • (2002) Chir Organi Mov , vol.87 , pp. 169-174
    • Pascarella, R.1    Nasta, G.2    Nicolini, M.3
  • 24
    • 0026742484 scopus 로고
    • Interlocking nailing for fractures of femur and tibia
    • Pintore E, Maffulli N, Petricciuolo F. Interlocking nailing for fractures of femur and tibia. Injury 1992;23:381-7.
    • (1992) Injury , vol.23 , pp. 381-387
    • Pintore, E.1    Maffulli, N.2    Petricciuolo, F.3
  • 25
    • 0007450877 scopus 로고
    • Evolution of medullary fixation of fractures by the longitudinal pin
    • Rush LV, Rush HL. Evolution of medullary fixation of fractures by the longitudinal pin. Am J Surg 1949;78:324.
    • (1949) Am J Surg , vol.78 , pp. 324
    • Rush, L.V.1    Rush, H.L.2
  • 26
    • 0028528922 scopus 로고
    • Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: A fractured tibia model in sheep
    • Schemitsch EH, Kowalski MJ, Swiontkowski MF, et al. Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: a fractured tibia model in sheep. J Orthop Trauma 1994;8:373-82.
    • (1994) J Orthop Trauma , vol.8 , pp. 373-382
    • Schemitsch, E.H.1    Kowalski, M.J.2    Swiontkowski, M.F.3
  • 27
    • 0031661945 scopus 로고    scopus 로고
    • Screening times with image intensifier in orthopaedic trauma surgery
    • Sutherland AG, Finlayson DF. Screening times with image intensifier in orthopaedic trauma surgery. J R Coll Surg Edinb 1998;43:265-6.
    • (1998) J R Coll Surg Edinb , vol.43 , pp. 265-266
    • Sutherland, A.G.1    Finlayson, D.F.2
  • 28
    • 0025308981 scopus 로고
    • Interlocking nailing for treatment of segmental fractures of the femur
    • Wiss DA, Brien WW, Stetson WB. Interlocking nailing for treatment of segmental fractures of the femur. J Bone Joint Surg Am 1990;72:724-8.
    • (1990) J Bone Joint Surg Am , vol.72 , pp. 724-728
    • Wiss, D.A.1    Brien, W.W.2    Stetson, W.B.3
  • 29
    • 0029061589 scopus 로고
    • Unstable fractures of tibia treated with a reamed intramedullary interlocking nail
    • Wiss DA, Stetson WB. Unstable fractures of tibia treated with a reamed intramedullary interlocking nail. Clin Orthop 1995;315:56-63.
    • (1995) Clin Orthop , vol.315 , pp. 56-63
    • Wiss, D.A.1    Stetson, W.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.