메뉴 건너뛰기




Volumn 25, Issue 5-6, 2003, Pages 354-360

Transpedicular screwing of the seventh cervical vertebra: Anatomical considerations and surgical technique

Author keywords

Anatomical study; Bone screw; Cervical pedicle; Cervical vertebrae; Orthopedic fixation devices

Indexed keywords

ADULT; AGED; ARTICLE; BONE SCREW; CADAVER; CERVICAL SPINE INJURY; CLINICAL ARTICLE; CLINICAL EXAMINATION; COMPUTER ASSISTED TOMOGRAPHY; CONTROLLED STUDY; FEASIBILITY STUDY; FEMALE; HUMAN; IMAGE RECONSTRUCTION; MALE; MEDICAL ASSESSMENT; MEDICAL DECISION MAKING; MEDICAL LITERATURE; MORPHOLOGY; MORPHOMETRICS; PRACTICE GUIDELINE; PRIORITY JOURNAL; QUANTITATIVE ANALYSIS; SAFETY; SPINE STABILIZATION; SPINE SURGERY; SURGICAL ANATOMY; SURGICAL TECHNIQUE; VERTEBRA BODY;

EID: 0346243556     PISSN: 09301038     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00276-003-0163-5     Document Type: Article
Times cited : (31)

References (24)
  • 1
    • 0028012268 scopus 로고
    • Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: Description of the techniques and preliminary report
    • Abumi K, Itoh H, Taneichi H, Kaneda K (1994) Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J Spinal Disord 7: 19-28
    • (1994) J. Spinal Disord. , vol.7 , pp. 19-28
    • Abumi, K.1    Itoh, H.2    Taneichi, H.3    Kaneda, K.4
  • 2
    • 0031427940 scopus 로고    scopus 로고
    • Pedicle screw fixation for non-traumatic lesions of the cervical spine
    • Abumi K, Kaneda K (1997) Pedicle screw fixation for non-traumatic lesions of the cervical spine. Spine 22: 1853-1863
    • (1997) Spine , vol.22 , pp. 1853-1863
    • Abumi, K.1    Kaneda, K.2
  • 3
    • 0032950970 scopus 로고    scopus 로고
    • One-stage decompression and reconstruction of the cervical spine by using pedicle screw fixation systems
    • Abumi K, Kaneda K, Shono Y, Fujiya M (1999) One-stage decompression and reconstruction of the cervical spine by using pedicle screw fixation systems. J Neurosurg (Spine 1) 90: 19-26
    • (1999) J. Neurosurg. (Spine 1) , vol.90 , pp. 19-26
    • Abumi, K.1    Kaneda, K.2    Shono, Y.3    Fujiya, M.4
  • 4
    • 0032527483 scopus 로고    scopus 로고
    • Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology
    • Albert TJ, Klein GR, Joffe D, Vaccaro AR (1998) Use of cervicothoracic junction pedicle screws for reconstruction of complex cervical spine pathology. Spine 23: 1596-1599
    • (1998) Spine , vol.23 , pp. 1596-1599
    • Albert, T.J.1    Klein, G.R.2    Joffe, D.3    Vaccaro, A.R.4
  • 5
    • 0029927045 scopus 로고    scopus 로고
    • The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation
    • Ebraheim NA, Xu R, Yeasting RA (1996) The location of the vertebral artery foramen and its relation to posterior lateral mass screw fixation. Spine 21: 1291-1295
    • (1996) Spine , vol.21 , pp. 1291-1295
    • Ebraheim, N.A.1    Xu, R.2    Yeasting, R.A.3
  • 6
    • 0031022259 scopus 로고    scopus 로고
    • Morphometric evaluation of lower cervical pedicle and its projection
    • Ebraheim NA, Xu R, Knight T, Yeasting RA (1997) Morphometric evaluation of lower cervical pedicle and its projection. Spine 22: 1-5
    • (1997) Spine , vol.22 , pp. 1-5
    • Ebraheim, N.A.1    Xu, R.2    Knight, T.3    Yeasting, R.A.4
  • 7
    • 0346031828 scopus 로고
    • Contribution à l'étude des artères vertébrales
    • Recherche anatomique. Thesis, Lille
    • Francke JP (1971) Contribution à l'étude des artères vertébrales. Recherche anatomique. Thesis, Lille
    • (1971)
    • Francke, J.P.1
  • 8
    • 0028336015 scopus 로고
    • Transpedicular screw fixation of articular mass fracture-separation: Results of an anatomical study and operative technique
    • Jeanneret B, Gebhard JS, Magerl F (1994) Transpedicular screw fixation of articular mass fracture-separation: results of an anatomical study and operative technique. J Spinal Disord 7: 222-229
    • (1994) J. Spinal Disord. , vol.7 , pp. 222-229
    • Jeanneret, B.1    Gebhard, J.S.2    Magerl, F.3
  • 9
    • 0031010622 scopus 로고    scopus 로고
    • Cervical pedicle screws versus lateral mass screws, anatomic feasibility and biomechanical comparison
    • Jones EL, Heller JG, Silcox DH, Hutton WC (1997) Cervical pedicle screws versus lateral mass screws, anatomic feasibility and biomechanical comparison. Spine 22: 977-982
    • (1997) Spine , vol.22 , pp. 977-982
    • Jones, E.L.1    Heller, J.G.2    Silcox, D.H.3    Hutton, W.C.4
  • 10
    • 0025227980 scopus 로고
    • A comparative study of the transverse foramen of the sixth and seventh cervical vertebrae
    • Jovanovic MS (1990) A comparative study of the transverse foramen of the sixth and seventh cervical vertebrae. Surg Radiol Anat 12: 167-172
    • (1990) Surg. Radiol. Anat. , vol.12 , pp. 167-172
    • Jovanovic, M.S.1
  • 11
    • 0034466242 scopus 로고    scopus 로고
    • Cervical pedicle screw insertion: Assessment of safety and accuracy with computer-assisted image guidance
    • Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13: 218-224
    • (2000) J. Spinal Disord. , vol.13 , pp. 218-224
    • Kamimura, M.1    Ebara, S.2    Itoh, H.3    Tateiwa, Y.4    Kinoshita, T.5    Takaoka, K.6
  • 12
  • 13
    • 0035890086 scopus 로고    scopus 로고
    • Accuracy of cervical pedicle screw placement using the funnel technique
    • Karaikovic EE, Yingsakmongkol W, Gaines RW (2001) Accuracy of cervical pedicle screw placement using the funnel technique. Spine 26: 2456-2462
    • (2001) Spine , vol.26 , pp. 2456-2462
    • Karaikovic, E.E.1    Yingsakmongkol, W.2    Gaines, R.W.3
  • 14
    • 0027999435 scopus 로고
    • Biomechanical analysis of cervical stabilization systems: An assessment of transpedicular screw fixation in the cervical spine
    • Kotani Y, Cunningham BW, Abumi K, McAfee P (1994) Biomechanical analysis of cervical stabilization systems: an assessment of transpedicular screw fixation in the cervical spine. Spine 19: 2529-2539
    • (1994) Spine , vol.19 , pp. 2529-2539
    • Kotani, Y.1    Cunningham, B.W.2    Abumi, K.3    McAfee, P.4
  • 15
    • 0034669665 scopus 로고    scopus 로고
    • Cervical spine pedicle screws, a biomechanical comparison of two insertion techniques
    • Kowalski JM, Ludwig SC, Hutton WC, Heller JG (2000) Cervical spine pedicle screws, a biomechanical comparison of two insertion techniques. Spine 25: 2865-2867
    • (2000) Spine , vol.25 , pp. 2865-2867
    • Kowalski, J.M.1    Ludwig, S.C.2    Hutton, W.C.3    Heller, J.G.4
  • 16
    • 0003499790 scopus 로고
    • Traité des variations de la colonne vertébrale de l'homme
    • Vigot Frères, Paris
    • Le Double AF (1912) Traité des variations de la colonne vertébrale de l'homme. Vigot Frères, Paris, pp 1-48
    • (1912) , pp. 1-48
    • Le Double, A.F.1
  • 19
    • 0037855161 scopus 로고    scopus 로고
    • Essentials of spinal microsurgery
    • Lippincott-Raven, Philadelphia
    • McCulloch JA, Young PH (1998) Essentials of spinal microsurgery. Lippincott-Raven, Philadelphia, pp 121-150
    • (1998) , pp. 121-150
    • McCulloch, J.A.1    Young, P.H.2
  • 20
    • 0029848159 scopus 로고    scopus 로고
    • Anatomic considerations of transpedicular screw placement in the cervical spine
    • Miller RM, Ebraheim NA, Xu R, Yeasting RA (1996) Anatomic considerations of transpedicular screw placement in the cervical spine. Spine 21: 2317-2322
    • (1996) Spine , vol.21 , pp. 2317-2322
    • Miller, R.M.1    Ebraheim, N.A.2    Xu, R.3    Yeasting, R.A.4
  • 21
    • 0026040571 scopus 로고
    • Cervical human vertebrae, quantitative three-dimensional anatomy of the middle and lower regions
    • Panjabi M, Duranceau J, Goel V, Oxland T, Takata K (1991) Cervical human vertebrae, quantitative three-dimensional anatomy of the middle and lower regions. Spine 16: 861-869
    • (1991) Spine , vol.16 , pp. 861-869
    • Panjabi, M.1    Duranceau, J.2    Goel, V.3    Oxland, T.4    Takata, K.5
  • 22
    • 0033759317 scopus 로고    scopus 로고
    • Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures
    • Ugur HC, Attar A, Uz A, Egemen N, Caglar S, Genc Y (2000) Surgical anatomic evaluation of the cervical pedicle and adjacent neural structures. Neurosurgery 47: 1162-1169
    • (2000) Neurosurgery , vol.47 , pp. 1162-1169
    • Ugur, H.C.1    Attar, A.2    Uz, A.3    Egemen, N.4    Caglar, S.5    Genc, Y.6
  • 23
    • 0028954599 scopus 로고
    • Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect
    • Xu R, Ebraheim NA, Yeasting R, Wong F, Jackson WT (1995) Anatomy of C7 lateral mass and projection of pedicle axis on its posterior aspect. J Spinal Disord 8: 116-120
    • (1995) J. Spinal Disord. , vol.8 , pp. 116-120
    • Xu, R.1    Ebraheim, N.A.2    Yeasting, R.3    Wong, F.4    Jackson, W.T.5
  • 24
    • 0033105597 scopus 로고    scopus 로고
    • Anatomic relation between the cervical pedicle and the adjacent neural structures
    • Xu R, Kang A, Ebraheim NA, Yeasting RA (1999) Anatomic relation between the cervical pedicle and the adjacent neural structures. Spine 24: 451-454
    • (1999) Spine , vol.24 , pp. 451-454
    • Xu, R.1    Kang, A.2    Ebraheim, N.A.3    Yeasting, R.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.