메뉴 건너뛰기




Volumn 26, Issue 4, 2003, Pages 390-400

Functional electrical stimulation for augmented walking in adolescents with incomplete spinal cord injury

Author keywords

Adolescents; Energy cost; FES; Functional electrical stimulation; Gait; Incomplete spinal cord injury; Paraplegia; Tetraplegia

Indexed keywords

ADOLESCENT; CASE REPORT; ELECTROSTIMULATION THERAPY; ENERGY COST; FEMALE; FUNCTIONAL ELECTRICAL STIMULATION; GAIT; HIP; HUMAN; KINEMATICS; KNEE; MALE; MUSCLE STRENGTH; PARAPLEGIA; PELVIS; QUADRIPLEGIA; REVIEW; SCHOOL CHILD; SPINAL CORD INJURY; WALKING; WALKING SPEED;

EID: 0346218133     PISSN: 10790268     EISSN: None     Source Type: Journal    
DOI: 10.1080/10790268.2003.11753711     Document Type: Review
Times cited : (29)

References (33)
  • 1
    • 0032847106 scopus 로고    scopus 로고
    • Comparison of functional electrical stimulation to long leg braces for upright mobility for children with complete thoracic level spinal injuries
    • Bonaroti D, Akers JM, Smith BT, Mulcahey MJ, Betz RR. Comparison of functional electrical stimulation to long leg braces for upright mobility for children with complete thoracic level spinal injuries. Arch Phys Med Rehabil. 1999;80:1047-1053.
    • (1999) Arch Phys Med Rehabil , vol.80 , pp. 1047-1053
    • Bonaroti, D.1    Akers, J.M.2    Smith, B.T.3    Mulcahey, M.J.4    Betz, R.R.5
  • 2
    • 0033408446 scopus 로고    scopus 로고
    • Implanted functional electrical stimulation system for mobility in paraplegia: A follow-up case report
    • Kobetic R, Triolo RJ, Uhlir JP, et al. Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report. IEEE Trans Rehabil Eng. 1999;7:390-398.
    • (1999) IEEE Trans Rehabil Eng , vol.7 , pp. 390-398
    • Kobetic, R.1    Triolo, R.J.2    Uhlir, J.P.3
  • 3
    • 0032956711 scopus 로고    scopus 로고
    • Hybrid functional electrical stimulation system for energy-efficient restoration of standing-up motion
    • Miyamoto S, Shimada Y, Sato K, Kagaya H, Matsunaga T, Obinata G. Hybrid functional electrical stimulation system for energy-efficient restoration of standing-up motion. Arch Phys Med Rehabil. 1999;80:40-47.
    • (1999) Arch Phys Med Rehabil , vol.80 , pp. 40-47
    • Miyamoto, S.1    Shimada, Y.2    Sato, K.3    Kagaya, H.4    Matsunaga, T.5    Obinata, G.6
  • 4
    • 0028443327 scopus 로고
    • Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation
    • Kobetic R, Marsolais EB. Synthesis of paraplegic gait with multichannel functional neuromuscular stimulation. IEEE Trans Rehab Eng. 1994;2:66-79.
    • (1994) IEEE Trans Rehab Eng , vol.2 , pp. 66-79
    • Kobetic, R.1    Marsolais, E.B.2
  • 5
    • 0030885059 scopus 로고    scopus 로고
    • Upper and lower extremity applications of functional electrical stimulation: A decade of research with children and adolescents with spinal injuries
    • Mulcahey MJ, Betz RR. Upper and lower extremity applications of functional electrical stimulation: a decade of research with children and adolescents with spinal injuries. Pediatr Phys Ther. 1997;9:113-122.
    • (1997) Pediatr Phys Ther , vol.9 , pp. 113-122
    • Mulcahey, M.J.1    Betz, R.R.2
  • 10
  • 11
    • 0016221672 scopus 로고
    • Kinesiology of lower extremity bracing
    • Perry JP. Kinesiology of lower extremity bracing. Clin Orthop. 1974;102:18-31.
    • (1974) Clin Orthop , vol.102 , pp. 18-31
    • Perry, J.P.1
  • 12
    • 0027199261 scopus 로고
    • The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury-observed benefits during gait studies
    • Granat MH, Ferguson AC, Andrews BJ, Delargy M. The role of functional electrical stimulation in the rehabilitation of patients with incomplete spinal cord injury-observed benefits during gait studies. Paraplegia. 1993;31:207-215.
    • (1993) Paraplegia , vol.31 , pp. 207-215
    • Granat, M.H.1    Ferguson, A.C.2    Andrews, B.J.3    Delargy, M.4
  • 13
    • 0027325885 scopus 로고
    • Electrical systems for improving locomotion after incomplete spinal cord injury: An assessment
    • Stein RB, Belanger M, Wheeler G, et al. Electrical systems for improving locomotion after incomplete spinal cord injury: an assessment. Arch Phys Med Rehabil. 1993;74:954-959.
    • (1993) Arch Phys Med Rehabil , vol.74 , pp. 954-959
    • Stein, R.B.1    Belanger, M.2    Wheeler, G.3
  • 14
    • 0033832196 scopus 로고    scopus 로고
    • Functional electrical stimulation-assisted walking for persons with incomplete spinal injuries: Changes in the kinematics and physiological cost of overground walking
    • Ladouceur M, Barbeau H. Functional electrical stimulation-assisted walking for persons with incomplete spinal injuries: changes in the kinematics and physiological cost of overground walking. Scand J Rehabil Med. 2000;32:72-79.
    • (2000) Scand J Rehabil Med , vol.32 , pp. 72-79
    • Ladouceur, M.1    Barbeau, H.2
  • 15
    • 0033828076 scopus 로고    scopus 로고
    • Functional electrical stimulation-assisted walking for persons with incomplete spinal injuries: Longitudinal changes in maximal overground walking speed
    • Ladouceur M, Barbeau H. Functional electrical stimulation-assisted walking for persons with incomplete spinal injuries: longitudinal changes in maximal overground walking speed. Scand J Rehabil Med. 2000;32:28-36.
    • (2000) Scand J Rehabil Med , vol.32 , pp. 28-36
    • Ladouceur, M.1    Barbeau, H.2
  • 16
    • 0030982953 scopus 로고    scopus 로고
    • Influence of electrically stimulated ankle plantar flexors on the swinging leg
    • Bajd T, Kralj A, Karcnik T, Savrin R, Benko H, Obreza P. Influence of electrically stimulated ankle plantar flexors on the swinging leg. Artif Organs. 1997;21:176-179.
    • (1997) Artif Organs , vol.21 , pp. 176-179
    • Bajd, T.1    Kralj, A.2    Karcnik, T.3    Savrin, R.4    Benko, H.5    Obreza, P.6
  • 17
    • 0033060401 scopus 로고    scopus 로고
    • Use of functional electrical stimulation in the lower extremities of incomplete spinal cord injured patients
    • Bajd T, Kralj A, Stefancic M, Lavrac N. Use of functional electrical stimulation in the lower extremities of incomplete spinal cord injured patients. Artif Organs. 1999;23:403-409.
    • (1999) Artif Organs , vol.23 , pp. 403-409
    • Bajd, T.1    Kralj, A.2    Stefancic, M.3    Lavrac, N.4
  • 19
    • 0033028372 scopus 로고    scopus 로고
    • The energy expenditure of normal and pathological gait
    • Waters RL, Mulroy S. The energy expenditure of normal and pathological gait. Gait Posture. 1999;9:207-231.
    • (1999) Gait Posture , vol.9 , pp. 207-231
    • Waters, R.L.1    Mulroy, S.2
  • 21
    • 0025424645 scopus 로고
    • Measurement of lower extremity kinematics during level walking
    • Kadaba MP, Ramakrishnan HK, Wootten ME. Measurement of lower extremity kinematics during level walking. J Orthop Res. 1990;8:383-392.
    • (1990) J Orthop Res , vol.8 , pp. 383-392
    • Kadaba, M.P.1    Ramakrishnan, H.K.2    Wootten, M.E.3
  • 22
    • 33644659288 scopus 로고    scopus 로고
    • International Standards for Neurological Classification of Spinal Injury
    • American Spinal Injuries Association. International Standards for Neurological Classification of Spinal Injury. J Spinal Cord Med. 2003;26(suppl 1):s50-s56
    • (2003) J Spinal Cord Med , vol.26 , Issue.SUPPL. 1
  • 23
    • 0028439538 scopus 로고
    • Design and clinical application of a double helix electrode for functional electrical stimulation
    • Scheiner A, Polando G, Marsolais EB. Design and clinical application of a double helix electrode for functional electrical stimulation. IEEE Trans Biomed Eng. 1994;41:425-431.
    • (1994) IEEE Trans Biomed Eng , vol.41 , pp. 425-431
    • Scheiner, A.1    Polando, G.2    Marsolais, E.B.3
  • 24
    • 0029818697 scopus 로고    scopus 로고
    • Home use of a functional electrical stimulation system for standing and mobility in adolescents with spinal cord injury
    • Moynahan M, Mullin C, Cohn J, et al. Home use of a functional electrical stimulation system for standing and mobility in adolescents with spinal cord injury. Arch Phys Med Rehabil. 1996;77:1005-1013.
    • (1996) Arch Phys Med Rehabil , vol.77 , pp. 1005-1013
    • Moynahan, M.1    Mullin, C.2    Cohn, J.3
  • 25
    • 0032214346 scopus 로고    scopus 로고
    • Comparison of discomfort associated with surface and percutaneous intramuscular electrical stimulation for persons with chronic hemiplegia
    • Chae J, Hart R. Comparison of discomfort associated with surface and percutaneous intramuscular electrical stimulation for persons with chronic hemiplegia. Am J Phys Med Rehabil. 1998;77:516-522.
    • (1998) Am J Phys Med Rehabil , vol.77 , pp. 516-522
    • Chae, J.1    Hart, R.2
  • 26
    • 0024694742 scopus 로고
    • Development and operation of portable and laboratory electrical stimulation systems for walking in paraplegic subjects
    • Borges D, Ferguson K, Kobetic R. Development and operation of portable and laboratory electrical stimulation systems for walking in paraplegic subjects. IEEE Trans Biomed Eng. 1989;36:798-801.
    • (1989) IEEE Trans Biomed Eng , vol.36 , pp. 798-801
    • Borges, D.1    Ferguson, K.2    Kobetic, R.3
  • 27
    • 0000123275 scopus 로고    scopus 로고
    • A portable 24 channel functional electrical stimulation system for upper and lower extremity applications
    • Langton A, ed. . Arlington, VA: PRENA Press: (abstract)
    • Smith BT, McGee B, Ignatoski M, Douglas J, Mulcahey MJ, Betz RR. A portable 24 channel functional electrical stimulation system for upper and lower extremity applications. In: Langton A, ed. Proceedings of the RESNA Annual Conference, June 1996. Arlington, VA: PRENA Press; 1996:276-278 (abstract).
    • (1996) Proceedings of the RESNA Annual Conference, June 1996 , pp. 276-278
    • Smith, B.T.1    McGee, B.2    Ignatoski, M.3    Douglas, J.4    Mulcahey, M.J.5    Betz, R.R.6
  • 28
    • 0002003827 scopus 로고    scopus 로고
    • Standing and walking with functional neuromuscular stimulation: Technical and clinical challenges
    • Harris GF, Smith PA, ed. New York: IEEE Press
    • Triolo RJ, Kobetic R, Betz RR. Standing and walking with functional neuromuscular stimulation: technical and clinical challenges. In: Harris GF, Smith PA, ed. Human Motion Analysis: Current Applications and Future Directions. New York: IEEE Press; 1996:318-350.
    • (1996) Human Motion Analysis: Current Applications and Future Directions , pp. 318-350
    • Triolo, R.J.1    Kobetic, R.2    Betz, R.R.3
  • 30
    • 0032847754 scopus 로고    scopus 로고
    • High- or low-technology measurements of energy expenditure in clinical gait analysis?
    • Boyd R, Fatone S, Rodda J, et al. High- or low-technology measurements of energy expenditure in clinical gait analysis? Dev Med Child Neurol. 1999;41:676-682.
    • (1999) Dev Med Child Neurol , vol.41 , pp. 676-682
    • Boyd, R.1    Fatone, S.2    Rodda, J.3
  • 33
    • 0346767214 scopus 로고    scopus 로고
    • Intramuscular electromyography as a means of triggering functional electrical stimulation to improve gait for children with motor incomplete spinal cord injury
    • April 1999
    • Smith BT, Ringleb S, Hillstrom H, Ward T, Betz RR. Intramuscular electromyography as a means of triggering functional electrical stimulation to improve gait for children with motor incomplete spinal cord injury. In: Proceedings of the 2nd World Congress in Neurological Rehabilitation, April 1999. 1999:100.
    • (1999) Proceedings of the 2nd World Congress in Neurological Rehabilitation , pp. 100
    • Smith, B.T.1    Ringleb, S.2    Hillstrom, H.3    Ward, T.4    Betz, R.R.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.