메뉴 건너뛰기




Volumn 15, Issue 3, 2003, Pages 95-99

Roentgen Stereophotogrammetric Analysis of Motion between the Bone and the Socket in a Transtibial Amputation Prosthesis: A Case Study

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AMPUTATION STUMP; ARTICLE; BELOW KNEE AMPUTATION; BODY MOVEMENT; BONE RADIOGRAPHY; CASE REPORT; GAIT; HUMAN; JOINT PROSTHESIS; LEG MOVEMENT; LEG PROSTHESIS; MALE; ROTATION; SIMULATION; STEREOPHOTOGRAMMETRY; X RAY ANALYSIS;

EID: 0346056970     PISSN: 10408800     EISSN: None     Source Type: Journal    
DOI: 10.1097/00008526-200307000-00008     Document Type: Article
Times cited : (34)

References (9)
  • 1
    • 0035704473 scopus 로고    scopus 로고
    • Osseointegration in skeletal reconstruction and rehabilitation: A review
    • Branemark R, Branemark PI, Rydevik B, Myers RR. Osseointegration in skeletal reconstruction and rehabilitation: a review. J Rehabil Res Dev. 2001;38:175-181.
    • (2001) J Rehabil Res Dev , vol.38 , pp. 175-181
    • Branemark, R.1    Branemark, P.I.2    Rydevik, B.3    Myers, R.R.4
  • 2
    • 0014644224 scopus 로고
    • Roentgenological study of movements of the amputation stump with the prosthesis socket in below-knee amputees fitted with a PTB prosthesis
    • Eriksson U, Lundberg R. Roentgenological study of movements of the amputation stump with the prosthesis socket in below-knee amputees fitted with a PTB prosthesis. Acta Orthop Scand. 1969;40:520-529.
    • (1969) Acta Orthop Scand , vol.40 , pp. 520-529
    • Eriksson, U.1    Lundberg, R.2
  • 3
    • 0016794193 scopus 로고
    • Roentgenological study of the stump-socket contact and skeletal displacement in the PTB-suction prosthesis
    • Grevsten S, Eriksson U. Roentgenological study of the stump-socket contact and skeletal displacement in the PTB-suction prosthesis. Ups J Med Sci. 1975;80:49-57.
    • (1975) Ups J Med Sci , vol.80 , pp. 49-57
    • Grevsten, S.1    Eriksson, U.2
  • 4
    • 0027252937 scopus 로고
    • Movement of the tibial end in a PTB prosthesis socket: A sagittal x-ray study of the PTB prosthesis
    • Lilja M, Johansson T, Öberg T. Movement of the tibial end in a PTB prosthesis socket: a sagittal x-ray study of the PTB prosthesis. Prosthet Orthot Int. 1993;17:21-26.
    • (1993) Prosthet Orthot Int , vol.17 , pp. 21-26
    • Lilja, M.1    Johansson, T.2    Öberg, T.3
  • 5
    • 0023896323 scopus 로고
    • Radiological evaluation of prosthetic fit in below-knee amputees
    • Newton RL, Morgan D, Schreiber MH. Radiological evaluation of prosthetic fit in below-knee amputees. Skeletal Radiol. 1988;17: 276-280.
    • (1988) Skeletal Radiol , vol.17 , pp. 276-280
    • Newton, R.L.1    Morgan, D.2    Schreiber, M.H.3
  • 6
    • 0024388994 scopus 로고
    • Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
    • Selvik G. Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system. Acta Orthop Scand Suppl. 1989;232:1-51
    • (1989) Acta Orthop Scand Suppl , vol.232 , pp. 1-51
    • Selvik, G.1
  • 7
    • 0022522401 scopus 로고
    • Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation
    • Ryd L. Micromotion in knee arthroplasty. A roentgen stereophotogrammetric analysis of tibial component fixation. Acta Orthop Scand Suppl. 1986;220:1-80.
    • (1986) Acta Orthop Scand Suppl , vol.220 , pp. 1-80
    • Ryd, L.1
  • 8
    • 0027991349 scopus 로고
    • Gait in male transtibial amputees: A comparative study with healthy subjects in relation to walking speed
    • Hermodsson Y, Ekdahl C, Persson BM, Roxendal G. Gait in male transtibial amputees: a comparative study with healthy subjects in relation to walking speed. Prosthet Orthot Int. 1994;18:68-77.
    • (1994) Prosthet Orthot Int , vol.18 , pp. 68-77
    • Hermodsson, Y.1    Ekdahl, C.2    Persson, B.M.3    Roxendal, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.