메뉴 건너뛰기




Volumn 39, Issue 4, 2003, Pages 347-358

Compliance of a biocomposite vascular tissue in longitudinal and circumferential directions as a basis for creating artificial substitutes

Author keywords

Anisotropy; Artificial substitutes; Carotid arteries; Collagen fibers; Elastin membranes; Intraluminal pressure; Mechanical properties; Stretch ratio; Undulation level; Vascular tissue

Indexed keywords

ANISOTROPY; BIOCOMPATIBILITY; BIOLOGICAL MEMBRANES; CARDIOVASCULAR SYSTEM; COLLAGEN; COMPOSITE MATERIALS; DEFORMATION; HISTOLOGY; LOADS (FORCES); MECHANICAL TESTING; PRESSURE EFFECTS; STIFFNESS; STRESSES; TISSUE;

EID: 0346009131     PISSN: 01915665     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1025698628850     Document Type: Article
Times cited : (7)

References (48)
  • 1
    • 0023875077 scopus 로고
    • Isotropy and anisotropy of the arterial wall
    • H. W. Weizsacker and J. G. Pinto, "Isotropy and anisotropy of the arterial wall," J. Biomech., 21, 477-487 (1988).
    • (1988) J. Biomech. , vol.21 , pp. 477-487
    • Weizsacker, H.W.1    Pinto, J.G.2
  • 2
    • 0031460986 scopus 로고    scopus 로고
    • The degree of nonlinearity and anisotropy of blood vessel elasticity
    • J. Zhou and Y. C. Fung, "The degree of nonlinearity and anisotropy of blood vessel elasticity," Proc. Nat. Acad. Sci. USA, 94, No. 26, 14255-14260 (1997).
    • (1997) Proc. Nat. Acad. Sci. USA , vol.94 , Issue.26 , pp. 14255-14260
    • Zhou, J.1    Fung, Y.C.2
  • 4
    • 0015383019 scopus 로고
    • Nonlinear anisotropic elastic properties of the canine aorta
    • R. N. Vaishnav, J. T. Young, J. S. Janicki, and D. J. Patel, "Nonlinear anisotropic elastic properties of the canine aorta," Biophys. J., No. 12, 1008-1027 (1972).
    • (1972) Biophys. J. , Issue.12 , pp. 1008-1027
    • Vaishnav, R.N.1    Young, J.T.2    Janicki, J.S.3    Patel, D.J.4
  • 5
    • 0016555309 scopus 로고
    • Anisotropic properties of the canine carotid artery in vivo
    • R. H. Cox, "Anisotropic properties of the canine carotid artery in vivo," J. Biomech., No. 8, 293-300 (1975).
    • (1975) J. Biomech. , Issue.8 , pp. 293-300
    • Cox, R.H.1
  • 6
    • 0021464816 scopus 로고
    • Elastase, collagenase, and the biaxial elastic properties of dog carotid artery
    • P. B. Dobrin and T. R. Canfield, "Elastase, collagenase, and the biaxial elastic properties of dog carotid artery," Am. J. Physiol., 247, 124-131 (1984).
    • (1984) Am. J. Physiol. , vol.247 , pp. 124-131
    • Dobrin, P.B.1    Canfield, T.R.2
  • 7
    • 0002832470 scopus 로고
    • Mechanical properties of arteries and arterial grafts
    • G. Hastings (ed.), Springer, London
    • T. V. How, "Mechanical properties of arteries and arterial grafts," in: G. Hastings (ed.), Cardiovascular Biomaterials Springer, London (1992), pp. 1-35.
    • (1992) Cardiovascular Biomaterials , pp. 1-35
    • How, T.V.1
  • 8
    • 0026361009 scopus 로고
    • The mechanical test method of cardiovascular and related biomaterials
    • A. T. Yokobori and T. Yokobori, "The mechanical test method of cardiovascular and related biomaterials," Bio-Med. Mater. Eng., No. 1, 25-43 (1991).
    • (1991) Bio-med. Mater. Eng. , Issue.1 , pp. 25-43
    • Yokobori, A.T.1    Yokobori, T.2
  • 12
    • 0022254893 scopus 로고
    • The pressure-dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five-component model
    • G. J. Langewouters, K. H. Wesseling, and W. J. Goedhard, "The pressure-dependent dynamic elasticity of 35 thoracic and 16 abdominal human aortas in vitro described by a five-component model," J. Biomech., 18, 613-620 (1985).
    • (1985) J. Biomech. , vol.18 , pp. 613-620
    • Langewouters, G.J.1    Wesseling, K.H.2    Goedhard, W.J.3
  • 13
    • 0002641401 scopus 로고
    • Vascular mechanics
    • J. Shepherd and F. Abboud (eds.), Springer, New York
    • P. B. Dobrin, "Vascular mechanics," in: J. Shepherd and F. Abboud (eds.), Handbook of Physiology. The Cardiovascular System, Springer, New York (1983), pp. 64-102.
    • (1983) Handbook of Physiology. The Cardiovascular System , pp. 64-102
    • Dobrin, P.B.1
  • 14
    • 0023525896 scopus 로고
    • Effect of variations in pressure and flow on the geometry of isolated canine carotid arteries
    • A. M. Brant, M. F. Teodori, R. L. Kormos, and H. S. Borovetz, "Effect of variations in pressure and flow on the geometry of isolated canine carotid arteries," J. Biomech., 20, 831-838 (1987).
    • (1987) J. Biomech. , vol.20 , pp. 831-838
    • Brant, A.M.1    Teodori, M.F.2    Kormos, R.L.3    Borovetz, H.S.4
  • 15
    • 0027690195 scopus 로고
    • Experimental approaches on measuring the mechanical properties and constitutive laws of arterial walls
    • K. Hayashi, "Experimental approaches on measuring the mechanical properties and constitutive laws of arterial walls," J. Biomech. Eng., 115, No. 4B, 481-488 (1993).
    • (1993) J. Biomech. Eng. , vol.115 , Issue.4 B , pp. 481-488
    • Hayashi, K.1
  • 16
    • 0024891142 scopus 로고
    • Experimental determination of wall shear rate in canine carotid arteries perfused in vitro
    • G. A. Johnson, T. K. Hung, A. M. Brant, and H. S. Borovetz, "Experimental determination of wall shear rate in canine carotid arteries perfused in vitro," J. Biomech., 22, 1141-1150 (1989).
    • (1989) J. Biomech. , vol.22 , pp. 1141-1150
    • Johnson, G.A.1    Hung, T.K.2    Brant, A.M.3    Borovetz, H.S.4
  • 17
    • 0025891767 scopus 로고
    • Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcation
    • K. Pertold, M. Resch, and R. Peter, "Three-dimensional numerical analysis of pulsatile flow and wall shear stress in the carotid artery bifurcation," J. Biomech., 24, 409-420 (1991).
    • (1991) J. Biomech. , vol.24 , pp. 409-420
    • Pertold, K.1    Resch, M.2    Peter, R.3
  • 18
    • 0001371278 scopus 로고
    • Structural basis for the static mechanical properties of the aortic media
    • H. Wolinsky and S. Glagov, "Structural basis for the static mechanical properties of the aortic media," Circ. Res., 14, 400-413 (1964).
    • (1964) Circ. Res. , vol.14 , pp. 400-413
    • Wolinsky, H.1    Glagov, S.2
  • 19
    • 0026896744 scopus 로고
    • Finite-element analysis of arterial anastomoses with vein, Dacron, and PTFE grafts
    • K. B. Chandran, D. Gao, G. Han, H. Baraniewski, and J.D. Corson, "Finite-element analysis of arterial anastomoses with vein, Dacron, and PTFE grafts," Med. Biol. Eng. Comput., 30, No. 4, 413-418 (1992).
    • (1992) Med. Biol. Eng. Comput. , vol.30 , Issue.4 , pp. 413-418
    • Chandran, K.B.1    Gao, D.2    Han, G.3    Baraniewski, H.4    Corson, J.D.5
  • 20
    • 0028388787 scopus 로고
    • A study of the wall shear rate distribution near the end-to-end anastomosis of a rigid graft and a compliant artery
    • K. Rhee and J. Tarbell, "A study of the wall shear rate distribution near the end-to-end anastomosis of a rigid graft and a compliant artery," J. Biomech., 27, No.3, 329-338 (1994).
    • (1994) J. Biomech. , vol.27 , Issue.3 , pp. 329-338
    • Rhee, K.1    Tarbell, J.2
  • 21
    • 0029384669 scopus 로고
    • Development of a microporous compliant small bore vascular graft
    • A. Edwards, R. J. Carson, S. Bowald, and W. S. Quist, "Development of a microporous compliant small bore vascular graft," J. Biomater. Appl., 10, No. 2, 171-187 (1995).
    • (1995) J. Biomater. Appl. , vol.10 , Issue.2 , pp. 171-187
    • Edwards, A.1    Carson, R.J.2    Bowald, S.3    Quist, W.S.4
  • 22
    • 0030088149 scopus 로고    scopus 로고
    • Compliance and diameter mismatch affect the wall shear-rate distribution near an end-to-end anastomosis
    • W. Matthew, M. Weston, K. Rhee, and J. Tarbell, "Compliance and diameter mismatch affect the wall shear-rate distribution near an end-to-end anastomosis, "J. Biomech., 29, No. 2, 187-198 (1996).
    • (1996) J. Biomech. , vol.29 , Issue.2 , pp. 187-198
    • Matthew, W.1    Weston, M.2    Rhee, K.3    Tarbell, J.4
  • 23
    • 0030111848 scopus 로고    scopus 로고
    • Small-caliber vascular grafts. Pt. 1. State of the art
    • R. J. Zdrahala, "Small-caliber vascular grafts. Pt. 1. State of the art," J. Biomater. Appl., 10, No. 4, 309-329 (1996).
    • (1996) J. Biomater. Appl. , vol.10 , Issue.4 , pp. 309-329
    • Zdrahala, R.J.1
  • 24
    • 0042318045 scopus 로고    scopus 로고
    • Significance of porosity and compliance of microporous, polyurethane-based microarterial vessel on neoarterial wall regeneration
    • K. Doi and T. Matsuda, "Significance of porosity and compliance of microporous, polyurethane-based microarterial vessel on neoarterial wall regeneration," J. Biomed. Mater. Res., 37, No. 4, 573-584 (1997).
    • (1997) J. Biomed. Mater. Res. , vol.37 , Issue.4 , pp. 573-584
    • Doi, K.1    Matsuda, T.2
  • 26
    • 0002788393 scopus 로고
    • The role of mechanical properties in graft desing
    • H. Dardik (ed.), Year Book Medical Publisher, Chicago
    • W. M. Abbott and D. J. Bouchier-Hayes, "The role of mechanical properties in graft desing," in: H. Dardik (ed.), Graft Material Vascular Surgery, Year Book Medical Publisher, Chicago (1978), pp. 59-78.
    • (1978) Graft Material Vascular Surgery , pp. 59-78
    • Abbott, W.M.1    Bouchier-Hayes, D.J.2
  • 27
    • 0018898430 scopus 로고
    • Stiffness and elastic behavior of human intracranial and extracranial arteries
    • K. Hayashi, H. Handa, S. Nagasawa, A. Okumura, and K. Moritake, "Stiffness and elastic behavior of human intracranial and extracranial arteries," J. Biomech., 13, 175-184 (1980).
    • (1980) J. Biomech. , vol.13 , pp. 175-184
    • Hayashi, K.1    Handa, H.2    Nagasawa, S.3    Okumura, A.4    Moritake, K.5
  • 28
    • 0032603829 scopus 로고    scopus 로고
    • Associations between viscoelastic properties of large arteries and their extracellular matrix composition in abdominal aortic aneurysms in humans
    • P. Boutouyrie, C. Glaser, A. Moryusef, Y. Bezie, J. N. Fabiani, S. Laurent, and P. Lacolley, "Associations between viscoelastic properties of large arteries and their extracellular matrix composition in abdominal aortic aneurysms in humans," Therapie, 54, No. 1, 85-91 (1999).
    • (1999) Therapie , vol.54 , Issue.1 , pp. 85-91
    • Boutouyrie, P.1    Glaser, C.2    Moryusef, A.3    Bezie, Y.4    Fabiani, J.N.5    Laurent, S.6    Lacolley, P.7
  • 31
    • 0031835132 scopus 로고    scopus 로고
    • In vivo and In vitro mechanical properties of the sheep thoracic aorta in the perinatal period and adulthood
    • S. M. Wells, B. L. Langille, and S. L. Adamson, "In vivo and In vitro mechanical properties of the sheep thoracic aorta in the perinatal period and adulthood," Am. J. Physiol., 274, No. 5, Pt. 2, H1749-H1760 (1998).
    • (1998) Am. J. Physiol. , vol.274 , Issue.5 PART 2
    • Wells, S.M.1    Langille, B.L.2    Adamson, S.L.3
  • 32
    • 0030249026 scopus 로고    scopus 로고
    • Ex vivo biomechanical behavior of abdominal aortic aneurysm: Assessment using a new mathematical model
    • M. L. Raghavan, M. W. Webster, and D. A. Vorp, "Ex vivo biomechanical behavior of abdominal aortic aneurysm: assessment using a new mathematical model," Ann. Biomed. Eng., 24, 573-582 (1996).
    • (1996) Ann. Biomed. Eng. , vol.24 , pp. 573-582
    • Raghavan, M.L.1    Webster, M.W.2    Vorp, D.A.3
  • 33
    • 0031818179 scopus 로고    scopus 로고
    • Mechanics of end-to-end artery-to-PTFE graft anastomoses
    • P. B. Dobrin, R. Mirande, S. Kang, Q. S. Dong, and R. Mrkvicka, "Mechanics of end-to-end artery-to-PTFE graft anastomoses," Vasc. Surg., 12, No. 4, 317-323 (1998).
    • (1998) Vasc. Surg. , vol.12 , Issue.4 , pp. 317-323
    • Dobrin, P.B.1    Mirande, R.2    Kang, S.3    Dong, Q.S.4    Mrkvicka, R.5
  • 34
    • 0027280759 scopus 로고
    • The direct effect of graft compliance mismatch per se on the development of host arterial intimal hyperplasia at the anastomotic interface
    • M. H. Wu, Q. Shi, L. R. Sauvage, S. Kaplan, N. Hayashi, and M. D. Patel, "The direct effect of graft compliance mismatch per se on the development of host arterial intimal hyperplasia at the anastomotic interface," Ann. Vasc. Surg., 7, No. 2, 156-168 (1993).
    • (1993) Ann. Vasc. Surg. , vol.7 , Issue.2 , pp. 156-168
    • Wu, M.H.1    Shi, Q.2    Sauvage, L.R.3    Kaplan, S.4    Hayashi, N.5    Patel, M.D.6
  • 35
    • 0042200767 scopus 로고    scopus 로고
    • Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses
    • P. D. Ballyk, C. Walsh, J. Butary, and M. Ojha, "Compliance mismatch may promote graft-artery intimal hyperplasia by altering suture-line stresses," J. Biomech., 31, 229-237 (1998).
    • (1998) J. Biomech. , vol.31 , pp. 229-237
    • Ballyk, P.D.1    Walsh, C.2    Butary, J.3    Ojha, M.4
  • 36
    • 0031937815 scopus 로고    scopus 로고
    • Effect of prolonged pulsatile shear stress in vitro on endothelial cell seeded PTFE and compliant polyurethane vascular grafts
    • A. Giudiceandrea, A. M. Seifalian, B. Krijgsman, and G. Hamilton, "Effect of prolonged pulsatile shear stress in vitro on endothelial cell seeded PTFE and compliant polyurethane vascular grafts," Eur. J. Vase. Endovasc. Surg., 15, No. 2, 147-154 (1998).
    • (1998) Eur. J. Vase. Endovasc. Surg. , vol.15 , Issue.2 , pp. 147-154
    • Giudiceandrea, A.1    Seifalian, A.M.2    Krijgsman, B.3    Hamilton, G.4
  • 38
    • 0032809495 scopus 로고    scopus 로고
    • Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts
    • R. Reeder, J. Wolfe, N. Lianakis, T. Hinson, L. A. Geddes, and J. Obermiller, "Compliance, elastic modulus, and burst pressure of small-intestine submucosa (SIS), small-diameter vascular grafts," J. Biomed. Mater. Res., 47, No. 1, 65-70 (1999).
    • (1999) J. Biomed. Mater. Res. , vol.47 , Issue.1 , pp. 65-70
    • Reeder, R.1    Wolfe, J.2    Lianakis, N.3    Hinson, T.4    Geddes, L.A.5    Obermiller, J.6
  • 39
    • 0032744062 scopus 로고    scopus 로고
    • In vivo femoropopliteal arterial wall compliance in subjects with and without lower limb vascular disease
    • N. R. Tai, A. Giudiceandrea, H. J. Salacinski, A. M. Seifalian, and G. Hamilton, "In vivo femoropopliteal arterial wall compliance in subjects with and without lower limb vascular disease," J. Vase. Surg., 30, No. 5, 936-945 (1999).
    • (1999) J. Vase. Surg. , vol.30 , Issue.5 , pp. 936-945
    • Tai, N.R.1    Giudiceandrea, A.2    Salacinski, H.J.3    Seifalian, A.M.4    Hamilton, G.5
  • 40
    • 0018949444 scopus 로고
    • Matched elastic properties and successful arterial grafting
    • R. Walden, G. J. L'Italien, J. Megrman, and W. M. Abbott, "Matched elastic properties and successful arterial grafting," Arch. Surg., 115, No. 10, 1166-1169 (1980).
    • (1980) Arch. Surg. , vol.115 , Issue.10 , pp. 1166-1169
    • Walden, R.1    L'Italien, G.J.2    Megrman, J.3    Abbott, W.M.4
  • 41
    • 0030088149 scopus 로고    scopus 로고
    • Compliance and diameter mismatch affect the wall shear-rate distribution near an end-to-end anastomosis
    • M. W. Weston, K. Rhee,and J. M. Tarbell, "Compliance and diameter mismatch affect the wall shear-rate distribution near an end-to-end anastomosis," J. Biomech., 26, No. 2, 187-198 (1996).
    • (1996) J. Biomech. , vol.26 , Issue.2 , pp. 187-198
    • Weston, M.W.1    Rheeand, K.2    Tarbell, J.M.3
  • 42
    • 0020956289 scopus 로고
    • Effect of healing on small internal diameter arterial graft compliance
    • R. White, L. Goldberg, and F. Hirose, "Effect of healing on small internal diameter arterial graft compliance," Biomater. Med. Dev. Artif. Organs, No. 11, 21-29 (1983).
    • (1983) Biomater. Med. Dev. Artif. Organs , Issue.11 , pp. 21-29
    • White, R.1    Goldberg, L.2    Hirose, F.3
  • 43
  • 47
    • 2642619407 scopus 로고    scopus 로고
    • A completely biological tissue-engineered human blood vessel
    • N. L'Heureux, S. Paquesr, R. Labbe, L. Geremain, and F.A. Anger, "A completely biological tissue-engineered human blood vessel," FASEB J., No. 12, 47-56 (1998).
    • (1998) FASEB J. , Issue.12 , pp. 47-56
    • L'Heureux, N.1    Paquesr, S.2    Labbe, R.3    Geremain, L.4    Anger, F.A.5
  • 48
    • 0031553827 scopus 로고    scopus 로고
    • Biomecham'cs of human common carotid artery and design of novel hybrid textile compliant vascular grafts
    • B. S. Gupta and V. A. Kasyanov, "Biomecham'cs of human common carotid artery and design of novel hybrid textile compliant vascular grafts," J. Biomed. Mater. Res., 34, 341-349 (1997)
    • (1997) J. Biomed. Mater. Res. , vol.34 , pp. 341-349
    • Gupta, B.S.1    Kasyanov, V.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.