메뉴 건너뛰기




Volumn 16, Issue 3, 1996, Pages 253-265

An Evaluation of Torque (Moment) on Implant/Prosthesis with Staggered Buccal and Lingual Offset

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHM; ARTICLE; BIOMECHANICS; COMPARATIVE STUDY; DENTAL CARE; HUMAN; MASTICATION; METHODOLOGY; TOOTH IMPLANTATION; TOOTH PROSTHESIS; TORQUE;

EID: 0345883982     PISSN: 01987569     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (26)

References (21)
  • 1
    • 0345580601 scopus 로고
    • Preventing prosthetic overload induced by bending
    • Rangert B, Sullivan R. Preventing prosthetic overload induced by bending. Nobelpharma News 1993;7:4-5.
    • (1993) Nobelpharma News , vol.7 , pp. 4-5
    • Rangert, B.1    Sullivan, R.2
  • 2
    • 0029366883 scopus 로고
    • A comparison of implant/prosthesis loading with four clinical variables
    • Weinberg LA, Kruger B. A comparison of implant/prosthesis loading with four clinical variables. Int J Prosthodont 1995;8:421-433
    • (1995) Int J Prosthodont , vol.8 , pp. 421-433
    • Weinberg, L.A.1    Kruger, B.2
  • 3
    • 0025441725 scopus 로고
    • Finite element analysis of six endosseous implants
    • Rieger MR, Mayberry MS, Brose MO. Finite element analysis of six endosseous implants. J Prosthet Dent 1990;63:671-676.
    • (1990) J Prosthet Dent , vol.63 , pp. 671-676
    • Rieger, M.R.1    Mayberry, M.S.2    Brose, M.O.3
  • 4
    • 0026266914 scopus 로고
    • Three-dimensional finite element stress analysis in and around the Screw-Vent implant
    • Clelland ML Ismail YH, Zaki HS, Pipko D. Three-dimensional finite element stress analysis in and around the Screw-Vent implant. Int J Oral Maxillofac Implants 1991;6:391-398.
    • (1991) Int J Oral Maxillofac Implants , vol.6 , pp. 391-398
    • Clelland, M.L.1    Ismail, Y.H.2    Zaki, H.S.3    Pipko, D.4
  • 5
    • 0026926786 scopus 로고
    • The effect of abutment angulation on stress transfer for an implant
    • Clelland NL, Gilat A. The effect of abutment angulation on stress transfer for an implant. J Prosthodont 1992;1:24-28.
    • (1992) J Prosthodont , vol.1 , pp. 24-28
    • Clelland, N.L.1    Gilat, A.2
  • 6
    • 0027829234 scopus 로고
    • Non-linear finite element contract analysis of dental implant components
    • Sakaguchi RO, Borgersen SE. Non-linear finite element contract analysis of dental implant components. Int J Oral Maxillofac Implants 1993;8:655-661.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 655-661
    • Sakaguchi, R.O.1    Borgersen, S.E.2
  • 7
    • 0020776467 scopus 로고
    • Biomechanical considerations in osseointegrated prostheses
    • Skalak R. Biomechanical considerations in osseointegrated prostheses. J Prosthet Dent 1983;49:843-848.
    • (1983) J Prosthet Dent , vol.49 , pp. 843-848
    • Skalak, R.1
  • 8
    • 0024031358 scopus 로고
    • Biomaterials and biomechanics in dental implants design
    • Brunski J. Biomaterials and biomechanics in dental implants design. Int J Maxillofac Implants 1988;3:85-97.
    • (1988) Int J Maxillofac Implants , vol.3 , pp. 85-97
    • Brunski, J.1
  • 9
    • 0141626137 scopus 로고
    • Effect of maxillary fixture location and angulation on load transfer
    • Wylie RS, Caputo AA, Alexandrias C, Habaki S. Effect of maxillary fixture location and angulation on load transfer. J Dent Res 1991,70:459.
    • (1991) J Dent Res , vol.70 , pp. 459
    • Wylie, R.S.1    Caputo, A.A.2    Alexandrias, C.3    Habaki, S.4
  • 10
    • 0027357731 scopus 로고
    • The biomechanics of force distribution in implant-supported prostheses
    • Weinberg LA. The biomechanics of force distribution in implant-supported prostheses. Int J Oral Maxillofac Implants 1993;8: 19-31.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 19-31
    • Weinberg, L.A.1
  • 11
    • 0028472832 scopus 로고
    • Biomechanical considerations when combining tooth-supported and implant-supported prostheses
    • Weinberg LA, Kruger B. Biomechanical considerations when combining tooth-supported and implant-supported prostheses. Oral Surg Oral Med Oral Pathol 1994;78:22-27.
    • (1994) Oral Surg Oral Med Oral Pathol , vol.78 , pp. 22-27
    • Weinberg, L.A.1    Kruger, B.2
  • 12
    • 0027564588 scopus 로고
    • Dental implants: Materials and design considerations
    • Smith DC. Dental implants: Materials and design considerations. Int J Prosthodont 1993;6:106-117.
    • (1993) Int J Prosthodont , vol.6 , pp. 106-117
    • Smith, D.C.1
  • 13
    • 1842587273 scopus 로고
    • Axial inclination and cuspal articulation in relation to force distribution
    • Weinberg LA. Axial inclination and cuspal articulation in relation to force distribution. J Prosthet Dent 1957;7:804-813.
    • (1957) J Prosthet Dent , vol.7 , pp. 804-813
    • Weinberg, L.A.1
  • 14
    • 1842587274 scopus 로고
    • Force distribution in splinted posterior teeth
    • Weinberg LA. Force distribution in splinted posterior teeth. Oral Surg Oral Med Oral Pathol 1957;10:1268-1276.
    • (1957) Oral Surg Oral Med Oral Pathol , vol.10 , pp. 1268-1276
    • Weinberg, L.A.1
  • 15
    • 0027735867 scopus 로고
    • Force moment systems on single maxillary anterior implants: Effects of incisal guidance, fixture orientation, and loss of bone support
    • Katona TR, Goodacre CT, Brown DR, Roberts WE. Force moment systems on single maxillary anterior implants: Effects of incisal guidance, fixture orientation, and loss of bone support. Int J Oral Maxillofac Implants 1993;8:512-522.
    • (1993) Int J Oral Maxillofac Implants , vol.8 , pp. 512-522
    • Katona, T.R.1    Goodacre, C.T.2    Brown, D.R.3    Roberts, W.E.4
  • 17
    • 84995803327 scopus 로고
    • Clinical utilization of non-rotational capability in osseointegrated prostheses
    • Weinberg LA, Kruger B. Clinical utilization of non-rotational capability in osseointegrated prostheses. Int J Oral Maxillofac Implants 1994;9:326-332.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 326-332
    • Weinberg, L.A.1    Kruger, B.2
  • 18
    • 0027584215 scopus 로고
    • CT scan as a radiologic data base for optimum implant orientation
    • Weinberg LA. CT scan as a radiologic data base for optimum implant orientation. J Prosthet Dent 1993;69:381-385.
    • (1993) J Prosthet Dent , vol.69 , pp. 381-385
    • Weinberg, L.A.1
  • 19
    • 0026456121 scopus 로고
    • The influence of residual ridge resorption patterns on implant fixture placement and tooth position. Part II. Presurgical determination of prosthesis type and design
    • Mecall RA, Rosenfeld AL. The influence of residual ridge resorption patterns on implant fixture placement and tooth position. Part II. Presurgical determination of prosthesis type and design. Int J Periodont Rest Dent 1992;12:32-51.
    • (1992) Int J Periodont Rest Dent , vol.12 , pp. 32-51
    • Mecall, R.A.1    Rosenfeld, A.L.2
  • 20
    • 0001886487 scopus 로고
    • Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period, monograph, Almqvist and Wiskell Int, Stockholm
    • Brånemark P-I, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period, monograph, Almqvist and Wiskell Int, Stockholm. Scand J Plast Reconstr Surg 1977;11(suppl 16).
    • (1977) Scand J Plast Reconstr Surg , vol.11 , Issue.16 SUPPL.
    • Brånemark, P.-I.1    Hansson, B.O.2    Adell, R.3    Breine, U.4    Lindstrom, J.5    Hallen, O.6
  • 21
    • 0026084439 scopus 로고
    • The excessive loss of Brånemark fixtures in Type IV bone: A 5-year analysis
    • Jaffin RA, Berman CL. The excessive loss of Brånemark fixtures in Type IV bone: A 5-year analysis. J Periodontol 1991;62:2-4.
    • (1991) J Periodontol , vol.62 , pp. 2-4
    • Jaffin, R.A.1    Berman, C.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.