메뉴 건너뛰기




Volumn 117, Issue 11, 2003, Pages 850-853

Delayed loss of residual hearing in Clarion® cochlear implant users

Author keywords

Audiometry, Pure Tone; Cochlear Implants

Indexed keywords

ARTICLE; AUDITORY THRESHOLD; COCHLEA; CONTROLLED STUDY; ELECTROSTIMULATION; HEARING LOSS; HUMAN; IMPLANTATION; MAJOR CLINICAL STUDY; POSTOPERATIVE PERIOD; PREOPERATIVE EVALUATION; SPEECH PERCEPTION;

EID: 0345415773     PISSN: 00222151     EISSN: None     Source Type: Journal    
DOI: 10.1258/002221503322542836     Document Type: Article
Times cited : (18)

References (10)
  • 1
    • 0024330461 scopus 로고
    • Loss of residual hearing after cochlear implantation
    • Bogess W, Baker J, Balkany T. Loss of residual hearing after cochlear implantation. Laryngoscope 1989;99:1002-5
    • (1989) Laryngoscope , vol.99 , pp. 1002-1005
    • Bogess, W.1    Baker, J.2    Balkany, T.3
  • 2
    • 0030897687 scopus 로고    scopus 로고
    • Conservation of residual hearing with cochlear implantation
    • Hodges AV, Schloffman J, Balkany T. Conservation of residual hearing with cochlear implantation. Am J Otol 1997;18:179-83
    • (1997) Am J Otol , vol.18 , pp. 179-183
    • Hodges, A.V.1    Schloffman, J.2    Balkany, T.3
  • 3
    • 0023928790 scopus 로고    scopus 로고
    • Post-operative audiometric evaluation of cochlear implant patients
    • Rizer EM, Arkis PN, Lippy WH. Post-operative audiometric evaluation of cochlear implant patients. Otolaryngol Head Neck Surg 1998;98:203-6
    • (1998) Otolaryngol Head Neck Surg , vol.98 , pp. 203-206
    • Rizer, E.M.1    Arkis, P.N.2    Lippy, W.H.3
  • 4
    • 0034584533 scopus 로고    scopus 로고
    • Residual hearing following a cochlear implantation: Effect of time and device
    • Bergeron F. Residual hearing following a cochlear implantation: effect of time and device. Adv Otorhinolaryngol 2000;57:389-92
    • (2000) Adv Otorhinolaryngol , vol.57 , pp. 389-392
    • Bergeron, F.1
  • 6
    • 0027248538 scopus 로고
    • Intracochlear placement of cochlear implant electrodes in soft surgery technique
    • Lehnhardt E. Intracochlear placement of cochlear implant electrodes in soft surgery technique. HNO 1993;41:356-9
    • (1993) HNO , vol.41 , pp. 356-359
    • Lehnhardt, E.1
  • 7
    • 0026002712 scopus 로고
    • Cochlear implants: Histopathologic findings related to performance in 16 human temporal bones
    • Fayad J, Linthicum FH Jr., Otto SR. Cochlear implants: Histopathologic findings related to performance in 16 human temporal bones. Am J Otol 1991;100:807-11
    • (1991) Am J Otol , vol.100 , pp. 807-811
    • Fayad, J.1    Linthicum Jr., F.H.2    Otto, S.R.3
  • 8
    • 0030782028 scopus 로고    scopus 로고
    • Are spiral ganglion cell numbers important for speech perception with a cochlear implant?
    • Blayney P. Are spiral ganglion cell numbers important for speech perception with a cochlear implant? Am J Otol 1997;18:S11-S12
    • (1997) Am J Otol , vol.18
    • Blayney, P.1
  • 9
    • 0030754832 scopus 로고    scopus 로고
    • Cochlear implant soft surgery: Fact or fantasy?
    • Cohen NL. Cochlear implant soft surgery: fact or fantasy? Otolaryngol Head Neck Surg 1997;117:214-6
    • (1997) Otolaryngol Head Neck Surg , vol.117 , pp. 214-216
    • Cohen, N.L.1