메뉴 건너뛰기




Volumn 38, Issue 4, 2003, Pages 319-340

Fire properties in near field of square fire source with longitudinal ventilation in tunnels

Author keywords

Aspect ratio; Flame tilt; Longitudinal forced ventilation; Smoke layer; Tunnel fire

Indexed keywords

ASPECT RATIO; FLAME RESEARCH; MATHEMATICAL MODELS; SMOKE; TUNNELS; VENTILATION;

EID: 0345382572     PISSN: 03797112     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0379-7112(02)00089-9     Document Type: Article
Times cited : (402)

References (22)
  • 1
    • 85185437521 scopus 로고    scopus 로고
    • Ventilation and emergency facilities of Daini Tomei, Meishin highway road tunnel
    • in Japanese
    • Yagi H., Era Y., Hatanaka K., Suzuki Y. Ventilation and emergency facilities of Daini Tomei, Meishin highway road tunnel. Highway Technol. 9:1997;218-226. in Japanese.
    • (1997) Highway Technol , vol.9 , pp. 218-226
    • Yagi, H.1    Era, Y.2    Hatanaka, K.3    Suzuki, Y.4
  • 2
    • 0344862897 scopus 로고
    • Car fire experiments in tunnel
    • [in Japanese]
    • Mizutani et al. Car fire experiments in tunnel. Tunnel Underground 1982;13(2):47 [in Japanese].
    • (1982) Tunnel Underground , vol.13 , Issue.2 , pp. 47
    • Mizutani1
  • 3
    • 0345294156 scopus 로고
    • Computational fluid dynamics simulations of fires in longitudinally ventilated tunnels
    • Lea CJ. Computational fluid dynamics simulations of fires in longitudinally ventilated tunnels. HSL Report No. IR/L/FR/94/10, 1995
    • (1995) HSL Report No. IR/L/FR/94/10
    • Lea, C.J.1
  • 6
    • 0029402398 scopus 로고
    • Control of smoke flow in tunnel fires
    • Oka Y., Atkinson G.T. Control of smoke flow in tunnel fires. Fire Safe J. 25:1995;305-322.
    • (1995) Fire Safe J , vol.25 , pp. 305-322
    • Oka, Y.1    Atkinson, G.T.2
  • 7
    • 78349275267 scopus 로고    scopus 로고
    • Ventilation criteria for preventing backing layer of smoke in case of tunnel fire
    • [in Japanese]
    • Yamada T et al. Ventilation criteria for preventing backing layer of smoke in case of tunnel fire. Report of National Research Institute of Fire Disaster, No. 83, 1997 [in Japanese].
    • (1997) Report of National Research Institute of Fire Disaster , vol.83
    • Yamada, T.1
  • 9
    • 0343789614 scopus 로고    scopus 로고
    • A model to evaluate tunnel fire characteristics
    • Megret O., Vauquelin O. A model to evaluate tunnel fire characteristics. Fire Safe J. 34:2000;393-401.
    • (2000) Fire Safe J , vol.34 , pp. 393-401
    • Megret, O.1    Vauquelin, O.2
  • 10
    • 0034320852 scopus 로고    scopus 로고
    • Control of smoke flow in tunnel fires using longitudinal ventilation systems - A study of the critical velocity
    • Wu Y., Bakar M.Z.A. Control of smoke flow in tunnel fires using longitudinal ventilation systems - a study of the critical velocity. Fire Safe J. 35:2000;363-390.
    • (2000) Fire Safe J , vol.35 , pp. 363-390
    • Wu, Y.1    Bakar, M.Z.A.2
  • 11
    • 0344431064 scopus 로고    scopus 로고
    • Mathematical model and experiments of axisymmetric spread of smoke front under ceiling. Part I
    • in Japanese
    • Matushita T.et al., Mathematical model and experiments of axisymmetric spread of smoke front under ceiling. Part I. Bull Jpn Assoc Fire Sci Eng. 48(1):1998;19-24. in Japanese Matushita T.et al., Mathematical model and experiments of axisymmetric spread of smoke front under ceiling. Part II. Bull Jpn Assoc Fire Sci Eng. 48(2):1998;1-8. in Japanese.
    • (1998) Bull Jpn Assoc Fire Sci Eng , vol.48 , Issue.1 , pp. 19-24
    • Matushita, T.1
  • 12
    • 0344431064 scopus 로고    scopus 로고
    • Mathematical model and experiments of axisymmetric spread of smoke front under ceiling. Part II
    • in Japanese
    • Matushita T.et al., Mathematical model and experiments of axisymmetric spread of smoke front under ceiling. Part I. Bull Jpn Assoc Fire Sci Eng. 48(1):1998;19-24. in Japanese Matushita T.et al., Mathematical model and experiments of axisymmetric spread of smoke front under ceiling. Part II. Bull Jpn Assoc Fire Sci Eng. 48(2):1998;1-8. in Japanese.
    • (1998) Bull Jpn Assoc Fire Sci Eng , vol.48 , Issue.2 , pp. 1-8
    • Matushita, T.1
  • 13
    • 0345294181 scopus 로고
    • Studies on the motion and the thermal behaviors of fire products through full scale corridor
    • in Japanese
    • Handa T.et al., Studies on the motion and the thermal behaviors of fire products through full scale corridor. Bull Jpn Assoc Fire Sci Eng. 28(2):1978;1-9. in Japanese.
    • (1978) Bull Jpn Assoc Fire Sci Eng , vol.28 , Issue.2 , pp. 1-9
    • Handa, T.1
  • 14
    • 85007947168 scopus 로고
    • Study on the hot-layer behaviors in tunnel fires, Part I. Experimental study of ceiling hot-layer
    • in Japanese
    • Kitahara R., Umezu M. Study on the hot-layer behaviors in tunnel fires, Part I. Experimental study of ceiling hot-layer. Bull Jpn Assoc Fire Sci Eng. 34(1):1984;7-15. in Japanese.
    • (1984) Bull Jpn Assoc Fire Sci Eng , vol.34 , Issue.1 , pp. 7-15
    • Kitahara, R.1    Umezu, M.2
  • 15
    • 0344862895 scopus 로고    scopus 로고
    • Properties of plume and near fire source in horizontally long and narrow spaces
    • in Japanese
    • Kurioka H., Oka Y., Satoh H., Kuwana H., Sugawa O. Properties of plume and near fire source in horizontally long and narrow spaces. J Constr Eng, AIJ. 546:2001;151-156. in Japanese.
    • (2001) J Constr Eng, AIJ , vol.546 , pp. 151-156
    • Kurioka, H.1    Oka, Y.2    Satoh, H.3    Kuwana, H.4    Sugawa, O.5
  • 16
    • 79957535676 scopus 로고    scopus 로고
    • Flame properties with longitudinal ventilation in a tunnel fire - In case of flames without touching tunnel ceiling
    • [in Japanese]
    • Oka Y, Kurioka H, Satoh H, Sugawa O. Flame properties with longitudinal ventilation in a tunnel fire - in case of flames without touching tunnel ceiling. Bull Jpn Assoc Fire Sci Eng 2001;51(2):1-12 [in Japanese].
    • (2001) Bull Jpn Assoc Fire Sci Eng , vol.51 , Issue.2 , pp. 1-12
    • Oka, Y.1    Kurioka, H.2    Satoh, H.3    Sugawa, O.4
  • 18
    • 85055952702 scopus 로고
    • Flame height from rectangular fire sources considering mixing factor
    • International Association of Fire Safety and Science
    • Sugawa O, Satoh H, Oka Y. Flame height from rectangular fire sources considering mixing factor. International Association of Fire Safety and Science, Proceedings of the Third International Symposium on Fire, 1991. p. 435-44.
    • (1991) Proceedings of the Third International Symposium on Fire , pp. 435-444
    • Sugawa, O.1    Satoh, H.2    Oka, Y.3
  • 20
    • 84951445300 scopus 로고
    • The rate of temperature rise in a compartment fire
    • Thomas PH. The rate of temperature rise in a compartment fire. Fire Research Note No.59, 1965
    • (1965) Fire Research Note , Issue.59
    • Thomas, P.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.