Volumn 83, Issue 5 B, 1999, Pages

Clinical significance of multiple sensor options: Rate response optimization, sensor blending, and trending

Author keywords

[No Author keywords available]

Indexed keywords

ARTIFICIAL HEART PACEMAKER; CHRONOTROPISM; CIRCADIAN RHYTHM; CONFERENCE PAPER; HEART PACING; HEART RATE; PRIORITY JOURNAL; QT INTERVAL; SENSOR;

EID: 0345355133     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(98)01020-0     Document Type: Conference Paper
Times cited : (16)

References (20)
  • 2
    • 0023769613 scopus 로고
    • Clinical experience with Sensolog 703: A new activity sensing rate responsive pacemaker
    • Lau C.P., Tse W.S., Camm A.J. Clinical experience with Sensolog 703 a new activity sensing rate responsive pacemaker . PACE Pacing Clin Electrophysiol. 11:1988;1444-1455.
    • (1988) PACE Pacing Clin Electrophysiol , vol.11 , pp. 1444-1455
    • Lau, C.P.1    Tse, W.S.2    Camm, A.J.3
  • 4
    • 0021733822 scopus 로고
    • Critical analysis of sensors for physiological responsive pacing
    • Gillette P. Critical analysis of sensors for physiological responsive pacing. PACE Pacing Clin Electrophysiol. 7:1984;1263-1266.
    • (1984) PACE Pacing Clin Electrophysiol , vol.7 , pp. 1263-1266
    • Gillette, P.1
  • 5
    • 0027988559 scopus 로고
    • Behavior of different activity-based pacemakers during treadmill exercise testing with variable slopes: A comparison of three activity-based pacing systems
    • Alt E., Matula M., Holzer K. Behavior of different activity-based pacemakers during treadmill exercise testing with variable slopes a comparison of three activity-based pacing systems . PACE Pacing Clin Electrophysiol. 17:1994;1761-1770.
    • (1994) PACE Pacing Clin Electrophysiol , vol.17 , pp. 1761-1770
    • Alt, E.1    Matula, M.2    Holzer, K.3
  • 6
    • 0029790920 scopus 로고    scopus 로고
    • Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system: The importance of individual sensor programming
    • Lau C.P., Leung S.K., Lee S.F.I. Delayed exercise rate response kinetics due to sensor cross-checking in a dual sensor rate adaptive pacing system the importance of individual sensor programming . PACE Pacing Clin Electrophysiol. 19:1996;1021-1025.
    • (1996) PACE Pacing Clin Electrophysiol , vol.19 , pp. 1021-1025
    • Lau, C.P.1    Leung, S.K.2    Lee, S.F.I.3
  • 8
    • 0344259859 scopus 로고
    • Problems with the slope adjustment and rate adaptation in rate-responsive pacemakers: Oscillation phenomena and sudden rate jumps
    • D.W. Behrenbeck, E. Sowton, G. Fontaine, & U.J. Winter. Damstadt: Steinkopf Verlag
    • Winter U.J., Behrenbeck D.W., Candelon B. Problems with the slope adjustment and rate adaptation in rate-responsive pacemakers oscillation phenomena and sudden rate jumps . Behrenbeck D.W., Sowton E., Fontaine G., Winter U.J. Cardiac Pacemakers. 1985;107-112 Steinkopf Verlag, Damstadt.
    • (1985) Cardiac Pacemakers , pp. 107-112
    • Winter, U.J.1    Behrenbeck, D.W.2    Candelon, B.3
  • 9
    • 0027294026 scopus 로고
    • Initial experience with a new single-chamber dual sensor rate-responsive pacemaker
    • Connell D.T. Initial experience with a new single-chamber dual sensor rate-responsive pacemaker. PACE Pacing Clin Electrophysiol. 16:1993;1833-1841.
    • (1993) PACE Pacing Clin Electrophysiol , vol.16 , pp. 1833-1841
    • Connell, D.T.1
  • 12
    • 24844474284 scopus 로고    scopus 로고
    • Heart rate variations obtained from a new closed loop rate adaptive pacemaker during head up tilt before and after isoproterenol infusion
    • (Abstr.)
    • Clémenty J., Garrigue S., Meunier J.F., Jarnier P., Le Métayer P. Heart rate variations obtained from a new closed loop rate adaptive pacemaker during head up tilt before and after isoproterenol infusion. (Abstr.) Arch Mal Coeur. 91:1998;242.
    • (1998) Arch Mal Coeur , vol.91 , pp. 242
    • Clémenty, J.1    Garrigue, S.2    Meunier, J.F.3    Jarnier, P.4    Le Métayer, P.5
  • 15
    • 0345122277 scopus 로고
    • The relationship between fitness level and daily heart rate behavior in normal adults: Implication for rate-adaptive pacing
    • (Abstr.)
    • Mianulli M., Birchfield D., Yakimow K. The relationship between fitness level and daily heart rate behavior in normal adults implication for rate-adaptive pacing . (Abstr.) PACE Pacing Clin Electrophysiol. 18:1995;870.
    • (1995) PACE Pacing Clin Electrophysiol , vol.18 , pp. 870
    • Mianulli, M.1    Birchfield, D.2    Yakimow, K.3
  • 16
    • 0029027077 scopus 로고
    • Initial clinical experience with a new dual sensor SSIR pacemaker controlled by body activity and minute ventilation
    • Alt E., Combs W., Fotuhi P., Bambl E., Wahlstrand J., Willhaus R. Initial clinical experience with a new dual sensor SSIR pacemaker controlled by body activity and minute ventilation. PACE Pacing Clin Electrophysiol. 18:1995;1487-1495.
    • (1995) PACE Pacing Clin Electrophysiol , vol.18 , pp. 1487-1495
    • Alt, E.1    Combs, W.2    Fotuhi, P.3    Bambl, E.4    Wahlstrand, J.5    Willhaus, R.6
  • 18
    • 0345553664 scopus 로고
    • Autocalibration algorithm in minute ventilation rate adaptive pacing
    • M. Santini. Armonk NY: Futura Publishing
    • Cazeau S., Bonnet J.L., Ritter P., et al. Autocalibration algorithm in minute ventilation rate adaptive pacing. Santini M. Progress in Clinical Pacing. 1994;335-341 Futura Publishing, Armonk NY.
    • (1994) Progress in Clinical Pacing , pp. 335-341
    • Cazeau, S.1    Bonnet, J.L.2    Ritter, P.3
  • 19
    • 0007182510 scopus 로고    scopus 로고
    • Appropriateness of automatic versus manual optimization in dual sensor rate responsive pacemaker
    • (Abstr.)
    • Leung S.K., Lau C.P., Law T.C., Chung F. Appropriateness of automatic versus manual optimization in dual sensor rate responsive pacemaker. (Abstr.) Eur J Cardiac Pacing Electrophysiol. 6:1996;168.
    • (1996) Eur J Cardiac Pacing Electrophysiol , vol.6 , pp. 168
    • Leung, S.K.1    Lau, C.P.2    Law, T.C.3    Chung, F.4
  • 20
    • 0003384534 scopus 로고    scopus 로고
    • Present status of rate-adaptive pacemakers: Should we be satisfied?
    • M. Santini. Armonk, NY: Futura Publishing
    • Barold S.S. Present status of rate-adaptive pacemakers should we be satisfied? Santini M. Progress in Clinical Pacing. 1996;153 Futura Publishing, Armonk, NY.
    • (1996) Progress in Clinical Pacing , pp. 153
    • Barold, S.S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.