메뉴 건너뛰기




Volumn 14, Issue 10, 2003, Pages 787-792

Quantitative ultrasound of the hand phalanges in patients with genetic disorders: A pilot case-control study

Author keywords

Genetic disorders; Hand phalanges; Quantitative ultrasound

Indexed keywords

AGE; ARTICLE; BODY SIZE; CHILD; CLINICAL ARTICLE; CONTROLLED STUDY; CORRELATION ANALYSIS; DOWN SYNDROME; EVALUATION; FEMALE; FRAGILE X SYNDROME; GENETIC DISORDER; HAND; HUMAN; MALE; MARFAN SYNDROME; MULTIPLE REGRESSION; PHALANX; PHENOTYPE; PILOT STUDY; PRIORITY JOURNAL; ULTRASOUND;

EID: 0345308468     PISSN: 0937941X     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00198-003-1400-9     Document Type: Article
Times cited : (15)

References (17)
  • 1
    • 0032101724 scopus 로고    scopus 로고
    • Comparison of ultrasound measurements at the heel between adults with mental retardation and control subjects
    • Aspray TJ, Francis RM, Thompson A, Quilliam SJ, Rawlings DJ, Tyrer SP (1998) Comparison of ultrasound measurements at the heel between adults with mental retardation and control subjects. Bone 22:665-668
    • (1998) Bone , vol.22 , pp. 665-668
    • Aspray, T.J.1    Francis, R.M.2    Thompson, A.3    Quilliam, S.J.4    Rawlings, D.J.5    Tyrer, S.P.6
  • 3
    • 0027425679 scopus 로고
    • Seizure related injures in multihandicapped patients with therapy-resistant epilepsy
    • Nakken KO, Lossius R (1993) Seizure related injures in multihandicapped patients with therapy-resistant epilepsy. Epilepsia 34:836-840
    • (1993) Epilepsia , vol.34 , pp. 836-840
    • Nakken, K.O.1    Lossius, R.2
  • 4
    • 0030667898 scopus 로고    scopus 로고
    • The assessment of development of bone mass in children by quantitative ultrasound through the proximal phalanxes of the hand
    • Halaba Z, Pluskiewicz W (1997) The assessment of development of bone mass in children by quantitative ultrasound through the proximal phalanxes of the hand. Ultrasound Med Biol 23:1331-1335
    • (1997) Ultrasound Med Biol , vol.23 , pp. 1331-1335
    • Halaba, Z.1    Pluskiewicz, W.2
  • 5
    • 0035028790 scopus 로고    scopus 로고
    • Bone quality assessment by quantitative ultrasound of proximal phalanxes of the hand in healthy subjects aged 3-21 years
    • Baroncelli GI, Federico G, Bertelloni S, et al (2001) Bone quality assessment by quantitative ultrasound of proximal phalanxes of the hand in healthy subjects aged 3-21 years. Pediatr Res 49:713-718
    • (2001) Pediatr Res , vol.49 , pp. 713-718
    • Baroncelli, G.I.1    Federico, G.2    Bertelloni, S.3
  • 6
    • 0031704385 scopus 로고    scopus 로고
    • Ultrasound measurements of proximal phalanges in Polish early postmenopausal women
    • Pluskiewicz W, Drozdzowska B (1998) Ultrasound measurements of proximal phalanges in Polish early postmenopausal women. Osteoporos Int 8:578-583
    • (1998) Osteoporos Int , vol.8 , pp. 578-583
    • Pluskiewicz, W.1    Drozdzowska, B.2
  • 7
    • 0033677170 scopus 로고    scopus 로고
    • Monitoring bone effect of transdermal hormone replacement therapy by ultrasound investigation at the phalanx: A 4-year follow-up study
    • Mauloni M, Rovatti LC, Cadossi R, de Terlizzi F, Ventura V, de Aloysio D (2000) Monitoring bone effect of transdermal hormone replacement therapy by ultrasound investigation at the phalanx: a 4-year follow-up study. Menopause 7:402-412
    • (2000) Menopause , vol.7 , pp. 402-412
    • Mauloni, M.1    Rovatti, L.C.2    Cadossi, R.3    De Terlizzi, F.4    Ventura, V.5    De Aloysio, D.6
  • 8
    • 0031658196 scopus 로고    scopus 로고
    • Ultrasound measurement of proximal phalanges in a normal Polish female population
    • Pluskiewicz W, Drozdzowska B (1998) Ultrasound measurement of proximal phalanges in a normal Polish female population. Osteoporos Int 8:349-354
    • (1998) Osteoporos Int , vol.8 , pp. 349-354
    • Pluskiewicz, W.1    Drozdzowska, B.2
  • 9
    • 0029980204 scopus 로고    scopus 로고
    • Ultrasound velocity measured at the proximal phalanges: Precision and age-related changes in normal females
    • Ventura V, Hans D, Schott AM, Giraud S, Delmas PD, Meunier PJ (1996) Ultrasound velocity measured at the proximal phalanges: precision and age-related changes in normal females. Rev Rhum 63:427-434
    • (1996) Rev Rhum , vol.63 , pp. 427-434
    • Ventura, V.1    Hans, D.2    Schott, A.M.3    Giraud, S.4    Delmas, P.D.5    Meunier, P.J.6
  • 10
    • 0031763528 scopus 로고    scopus 로고
    • Ultrasound measurements at the proximal phalanges in healthy women and patients with hip fractures
    • Alenfeld FE, Wüster C, Funck C, et al (1998) Ultrasound measurements at the proximal phalanges in healthy women and patients with hip fractures. Osteoporos Int 8:393-398
    • (1998) Osteoporos Int , vol.8 , pp. 393-398
    • Alenfeld, F.E.1    Wüster, C.2    Funck, C.3
  • 11
    • 0032962777 scopus 로고    scopus 로고
    • Reference curve and diagnostic sensitivity for a new ultrasound device for the phalanges, the DBM Sonic 1200, in Belgian women
    • Joly J, Westhovens R, Borghas H, et al (1999) Reference curve and diagnostic sensitivity for a new ultrasound device for the phalanges, the DBM Sonic 1200, in Belgian women. Osteoporos Int 9:284-289
    • (1999) Osteoporos Int , vol.9 , pp. 284-289
    • Joly, J.1    Westhovens, R.2    Borghas, H.3
  • 12
    • 0033730657 scopus 로고    scopus 로고
    • How well do radiographic absorptiometry and quantitative ultarasound predict osteoporosis at spine or hip?
    • Lippuner K, Fuchs G, Ruetsche AG, Perrelet R, Casez JP, Neto I (2000) How well do radiographic absorptiometry and quantitative ultarasound predict osteoporosis at spine or hip? J Clin Densitom 3:241-249
    • (2000) J Clin Densitom , vol.3 , pp. 241-249
    • Lippuner, K.1    Fuchs, G.2    Ruetsche, A.G.3    Perrelet, R.4    Casez, J.P.5    Neto, I.6
  • 13
    • 0343081031 scopus 로고    scopus 로고
    • Phalangeal osteosonogrammetry study: Age-related changes, diagnostic sensitivity, and discrimination power
    • Wüster C, Albanese C, De Aloysio D, et al (2000) Phalangeal osteosonogrammetry study: age-related changes, diagnostic sensitivity, and discrimination power. J Bone Miner Res 15:1603-1614
    • (2000) J Bone Miner Res , vol.15 , pp. 1603-1614
    • Wüster, C.1    Albanese, C.2    De Aloysio, D.3
  • 14
    • 0031442929 scopus 로고    scopus 로고
    • Three-year longitudinal study with quantitative ultrasound at the hand phalanx in a female population
    • Mele R, Masci G, Ventura V, de Aloysio D, Bicocchi M, Cadossi R (1997) Three-year longitudinal study with quantitative ultrasound at the hand phalanx in a female population. Osteoporos Int 7:550-557
    • (1997) Osteoporos Int , vol.7 , pp. 550-557
    • Mele, R.1    Masci, G.2    Ventura, V.3    De Aloysio, D.4    Bicocchi, M.5    Cadossi, R.6
  • 15
    • 0029112340 scopus 로고
    • Accurate assessment of precison errors: How to measure the reproducibility of bone densitometry techniques
    • Gluer CC, Blake G, Lu Y, Blunt BA, Jergas M, Genant HK (1995) Accurate assessment of precison errors: how to measure the reproducibility of bone densitometry techniques. Osteoporos Int 4:262-270
    • (1995) Osteoporos Int , vol.4 , pp. 262-270
    • Gluer, C.C.1    Blake, G.2    Lu, Y.3    Blunt, B.A.4    Jergas, M.5    Genant, H.K.6
  • 16
    • 0026673601 scopus 로고
    • Bone mineral density in children with Down syndrome detected by dual photon absorptiometry
    • Kao C, Chen CC, Wang SJ, Yeh SH (1992) Bone mineral density in children with Down syndrome detected by dual photon absorptiometry. Nucl Med Commun 13:773-775
    • (1992) Nucl Med Commun , vol.13 , pp. 773-775
    • Kao, C.1    Chen, C.C.2    Wang, S.J.3    Yeh, S.H.4
  • 17
    • 0029101825 scopus 로고
    • Low spinal and pelvic bone mineral density among individuals with Down syndrome
    • Sepulveda D, Allison DB, Gomez JE, et al (1995) Low spinal and pelvic bone mineral density among individuals with Down syndrome. AMJR 100:109-114
    • (1995) AMJR , vol.100 , pp. 109-114
    • Sepulveda, D.1    Allison, D.B.2    Gomez, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.