메뉴 건너뛰기




Volumn 13, Issue 1, 2003, Pages 16-21

Treatment planning for small complex-shape lesions and its experimental verification;Bestrahlungsplanung bei kleinen komplex-geformten läsionen und ihre experimentelle verifikation

Author keywords

Conformity; Film dosimetry; Radiosurgery; System test

Indexed keywords

ACCURACY; ARTICLE; BRAIN INJURY; COMPUTER PROGRAM; FILM DOSIMETER; GAMMA KNIFE RADIOSURGERY; IMAGE ANALYSIS; MEASUREMENT; PATIENT POSITIONING; PHANTOM; RADIATION DOSE DISTRIBUTION; STEREOTAXIC SURGERY; TREATMENT PLANNING; VALIDATION PROCESS;

EID: 0345270438     PISSN: 09393889     EISSN: None     Source Type: Journal    
DOI: 10.1078/0939-3889-00143     Document Type: Article
Times cited : (1)

References (9)
  • 2
    • 0035312502 scopus 로고    scopus 로고
    • Dynamic arc radiosurgery and radiotherapy: Commissioning and verification of dose distributions
    • Grebe, G., Pfaender, M., Roll, M., Luedemann, L.: Dynamic arc radiosurgery and radiotherapy: commissioning and verification of dose distributions. Int. J. Radiat. Oncol. Biol. Phys. 49, (2001) 1451-1460
    • (2001) Int. J. Radiat. Oncol. Biol. Phys. , vol.49 , pp. 1451-1460
    • Grebe, G.1    Pfaender, M.2    Roll, M.3    Luedemann, L.4
  • 3
    • 0000274968 scopus 로고    scopus 로고
    • Verification of dose plans using film dosimetry for quality assurance in radiosurgery
    • Kondziolka, D. (Hrsg.): Verlag S. Karger, Basel
    • Mack, A., Mack, G., Weltz, D., Czempiel, H., Kreiner, H.J.: Verification of dose plans using film dosimetry for quality assurance in radiosurgery. In: Kondziolka, D. (Hrsg.): Radiosurgery Vol. 4. Verlag S. Karger, Basel 2002, S. 213-227
    • (2002) Radiosurgery Vol. 4 , vol.4 , pp. 213-227
    • Mack, A.1    Mack, G.2    Weltz, D.3    Czempiel, H.4    Kreiner, H.J.5
  • 4
    • 0028218940 scopus 로고
    • The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics
    • McLaughlin, W. L., Soares, C. G., Sayeg, J. A., McCullough, E. C., Kline, R.W., Wu, A., Maitz, A. H.: The use of a radiochromic detector for the determination of stereotactic radiosurgery dose characteristics. Med. Phys. 21 (1994) 379-88
    • (1994) Med. Phys. , vol.21 , pp. 379-388
    • McLaughlin, W.L.1    Soares, C.G.2    Sayeg, J.A.3    McCullough, E.C.4    Kline, R.W.5    Wu, A.6    Maitz, A.H.7
  • 7
    • 0034088508 scopus 로고    scopus 로고
    • A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery
    • Robar, J.L., Clark, B.G.: A practical technique for verification of three-dimensional conformal dose distributions in stereotactic radiosurgery. Med. Phys. 27 (2000) 978-87
    • (2000) Med. Phys. , vol.27 , pp. 978-987
    • Robar, J.L.1    Clark, B.G.2
  • 9
    • 0031449664 scopus 로고    scopus 로고
    • Profil der ambulanten Radiochirurgie mit dem Gamma-Knife-System, Teil 1: Methode und multizentrisches Planungskonzept
    • Wowra, B., Czempiel, H., Cibis, R., Horstmann, G.A.: Profil der ambulanten Radiochirurgie mit dem Gamma-Knife-System, Teil 1: Methode und multizentrisches Planungskonzept. Radiologe 37 (1997) 995-1002
    • (1997) Radiologe , vol.37 , pp. 995-1002
    • Wowra, B.1    Czempiel, H.2    Cibis, R.3    Horstmann, G.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.