메뉴 건너뛰기




Volumn 42, Issue 24, 2003, Pages 7719-7721

A Robust Microporous Zinc Porphyrin Framework Solid

Author keywords

[No Author keywords available]

Indexed keywords

METAL; METALLOPORPHYRIN; ZEOLITE; ZINC DERIVATIVE;

EID: 0345017624     PISSN: 00201669     EISSN: None     Source Type: Journal    
DOI: 10.1021/ic034873g     Document Type: Article
Times cited : (119)

References (24)
  • 7
    • 0345226353 scopus 로고
    • Montanari, F., Casella, L., Eds.; Kluwer Academic Publishers: Dordrecht
    • Meunier, B. In Catalysis by Metal Complexes; Montanari, F., Casella, L., Eds.; Kluwer Academic Publishers: Dordrecht, 1994; Vol. 17.
    • (1994) Catalysis by Metal Complexes , vol.17
    • Meunier, B.1
  • 8
    • 0003641908 scopus 로고    scopus 로고
    • Kadish, K. M., Smith, K. M., Guilard, R., Eds.; Academic Press: San Diego, CA
    • Suslick, K. S. In The Porphyrin Handbook; Kadish, K. M., Smith, K. M., Guilard, R., Eds.; Academic Press: San Diego, CA, 2000; Vol. 4.
    • (2000) The Porphyrin Handbook , vol.4
    • Suslick, K.S.1
  • 15
    • 0345658246 scopus 로고    scopus 로고
    • note
    • 4O.
  • 17
    • 0345226354 scopus 로고    scopus 로고
    • Structure was solved and refined using SHELX97
    • (Sheldrick, G. M.; University of Göttingen: Göttingen, Germany
    • Structure was solved and refined using SHELX97 (Sheldrick, G. M. SHELXL97: Program for the Refinement of Crystal Structures; University of Göttingen: Göttingen, Germany, 1997).
    • (1997) SHELXL97: Program for the Refinement of Crystal Structures
  • 18
    • 0344795426 scopus 로고    scopus 로고
    • note
    • 2.
  • 19
    • 0345226355 scopus 로고    scopus 로고
    • note
    • X-ray powder diffraction patterns were collected on the same instrument used for single crystal measurements for 300 s with a 15 cm sample-to-detector distance. Solvated crystals used for XRD measurements were not crushed, but rather gently transferred along with mother liquor into a 1.0 mm X-ray capillary tube. Evacuated crystals were also not crushed prior to placement in a 1.0 mm X-ray capillary tube. The evacuated samples were resolvated directly in the capillary tube via a syringe.
  • 20
    • 0345658247 scopus 로고    scopus 로고
    • note
    • TGA of the evacuated solid shows minimal weight loss up to 400 °C, indicating that all of the solvates have been removed by the evacuation procedure.
  • 21
    • 0345658245 scopus 로고    scopus 로고
    • note
    • 2O. Calcd: C, 63.16; H, 4.42; N, 5.67; Zn, 15.43. Found: C, 63.29; H, 4.19; N, 5.56; Zn, 15.12. The water in the EA is from sorption from the atmosphere onto the surface of the solid prior to EA. The eight molecules of water included in the formula are in fair agreement with the TGA weight loss measured for the evacuated solid after 12 h of exposure to ambient atmosphere.
  • 24
    • 0345226359 scopus 로고    scopus 로고
    • note
    • An addition of 5% lattice strain to the noncentered simulated XRD gives a pattern with two broad maxima similar in shape, but not position, to the evacuated pattern. The proposed model for the evacuated case requires further development.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.