메뉴 건너뛰기




Volumn 25, Issue 7, 1999, Pages 1069-1076

Artificial neural networks and spatial temporal contour linking for automated endocardial contour detection on echocardiograms: A novel approach to determine left ventricular contractile function

Author keywords

Artificial neural networks; Echocardiography; Left ventricular ejection fraction; Left ventricular volume

Indexed keywords

BACKPROPAGATION; EDGE DETECTION; FEATURE EXTRACTION; IMAGE QUALITY; IMAGE SEGMENTATION; NEURAL NETWORKS; RADIOISOTOPES;

EID: 0344980101     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(99)00059-9     Document Type: Article
Times cited : (45)

References (25)
  • 1
    • 0032541846 scopus 로고    scopus 로고
    • New concept in echocardiography: Harmonic imaging of tissue without use of contrast agent
    • Caidahl K., Kazzam E., Lidberg J., et al. New concept in echocardiography harmonic imaging of tissue without use of contrast agent . Lancet. 352:(9136):1998;1264-1270.
    • (1998) Lancet , vol.352 , Issue.9136 , pp. 1264-1270
    • Caidahl, K.1    Kazzam, E.2    Lidberg, J.3
  • 2
    • 0031093726 scopus 로고    scopus 로고
    • Comparison of echocardiographic acoustic quantification system and radionuclide ventriculography for estimating left ventricular ejection fraction: Validation in patients without regional wall motion abnormalities
    • Chandra S., Bahl V.K., Reddy S.C., Bhargava B., Malhotra A., Wasir H.S. Comparison of echocardiographic acoustic quantification system and radionuclide ventriculography for estimating left ventricular ejection fraction validation in patients without regional wall motion abnormalities . Am Heart J. 133:(3):1997;359-363.
    • (1997) Am Heart J , vol.133 , Issue.3 , pp. 359-363
    • Chandra, S.1    Bahl, V.K.2    Reddy, S.C.3    Bhargava, B.4    Malhotra, A.5    Wasir, H.S.6
  • 4
    • 0022393062 scopus 로고
    • Reproducibility of left ventricular area and volume measurements using a computer endocardial edge-detection algorithm in normal subjects
    • Conetta D.A., Geiser E.A., Oliver L.H., Miller A.B., Conti C.R. Reproducibility of left ventricular area and volume measurements using a computer endocardial edge-detection algorithm in normal subjects. Am J Cardiol. 56:(15):1985;947-952.
    • (1985) Am J Cardiol , vol.56 , Issue.15 , pp. 947-952
    • Conetta, D.A.1    Geiser, E.A.2    Oliver, L.H.3    Miller, A.B.4    Conti, C.R.5
  • 5
    • 0025589084 scopus 로고
    • Matched filter identification of left ventricular endocardial boarders in transesophageal echocardiograms
    • Detmer P.R., Roy B.G., Martin W. Matched filter identification of left ventricular endocardial boarders in transesophageal echocardiograms. IEEE Trans Biomed Eng. 4:1994;396-404.
    • (1994) IEEE Trans Biomed Eng , vol.4 , pp. 396-404
    • Detmer, P.R.1    Roy, B.G.2    Martin, W.3
  • 6
    • 0026584407 scopus 로고
    • Application of artificial neural netwok to computer-aided diagnosis of coronary artery disease in myocardial SPECT bull′s-eye images
    • Fujita H., Katefuchi T., Uehara T., Nishimura T. Application of artificial neural netwok to computer-aided diagnosis of coronary artery disease in myocardial SPECT bull′s-eye images. J Nucl Med. 33:(2):1992;272-276.
    • (1992) J Nucl Med , vol.33 , Issue.2 , pp. 272-276
    • Fujita, H.1    Katefuchi, T.2    Uehara, T.3    Nishimura, T.4
  • 7
    • 0018679823 scopus 로고
    • Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography
    • Folland E.D. Assessment of left ventricular ejection fraction and volumes by real-time, two-dimensional echocardiography. Circulation. 60:1979;760-766.
    • (1979) Circulation , vol.60 , pp. 760-766
    • Folland, E.D.1
  • 10
    • 0032213369 scopus 로고    scopus 로고
    • Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction: Comparison with cine magnetic resonance imaging
    • Hundley W.G., Kizilbash A.M., Afridi I., Franco F., Peshock R.M., Grayburn P.A. Administration of an intravenous perfluorocarbon contrast agent improves echocardiographic determination of left ventricular volumes and ejection fraction comparison with cine magnetic resonance imaging . J Am Coll Cardiol. 32:(5):1998;1426-1432.
    • (1998) J Am Coll Cardiol , vol.32 , Issue.5 , pp. 1426-1432
    • Hundley, W.G.1    Kizilbash, A.M.2    Afridi, I.3    Franco, F.4    Peshock, R.M.5    Grayburn, P.A.6
  • 11
    • 0031047853 scopus 로고    scopus 로고
    • Doppler myocardial imaging vs. B-mode grey-scale imaging: A comparative in vitro and in vivo study into their relative efficacy in endocardial boundary detection
    • Lange A., Palka P., Caso P., Fenn L.N., Olszewski R., Ramo M.P., Shaw T.R., Nowicki A., Fox K.A., Sutherland G.R. Doppler myocardial imaging vs. B-mode grey-scale imaging a comparative in vitro and in vivo study into their relative efficacy in endocardial boundary detection . Ultrasound Med Biol. 23:(1):1997;69-75.
    • (1997) Ultrasound Med Biol , vol.23 , Issue.1 , pp. 69-75
    • Lange, A.1    Palka, P.2    Caso, P.3    Fenn, L.N.4    Olszewski, R.5    Ramo, M.P.6    Shaw, T.R.7    Nowicki, A.8    Fox, K.A.9    Sutherland, G.R.10
  • 12
    • 0031815657 scopus 로고    scopus 로고
    • Three-dimensional echocardiographic evaluation of left ventricular volume: Comparison of Doppler myocardial imaging and standard gray-scale imaging with cineventriculography - An in vitro and in vivo study
    • Lange A., Palka P., Nowicki A., Olszewski R., Anderson T., Adamus J., Sutherland G.R., Fox K.A. Three-dimensional echocardiographic evaluation of left ventricular volume comparison of Doppler myocardial imaging and standard gray-scale imaging with cineventriculography - an in vitro and in vivo study . Am Heart J. 135:(6 Pt. 1):1998;970-979.
    • (1998) Am Heart J , vol.135 , Issue.6 PT. 1 , pp. 970-979
    • Lange, A.1    Palka, P.2    Nowicki, A.3    Olszewski, R.4    Anderson, T.5    Adamus, J.6    Sutherland, G.R.7    Fox, K.A.8
  • 13
    • 0032929186 scopus 로고    scopus 로고
    • Paraplane analysis from precordial three-dimensional echocardiographic data sets for rapid and accurate quantification of left ventricular volume and function: A comparison with magnetic resonance imaging
    • Nosir Y.F., Stoker J., Kasprzak J.D., Lequin M.H., Dall'Agata A., Ten Cate F.J., Roelandt J.R. Paraplane analysis from precordial three-dimensional echocardiographic data sets for rapid and accurate quantification of left ventricular volume and function a comparison with magnetic resonance imaging . Am Heart J. 137:(1):1999;134-143.
    • (1999) Am Heart J , vol.137 , Issue.1 , pp. 134-143
    • Nosir, Y.F.1    Stoker, J.2    Kasprzak, J.D.3    Lequin, M.H.4    Dall'Agata, A.5    Ten Cate, F.J.6    Roelandt, J.R.7
  • 14
    • 0026464695 scopus 로고
    • Automated, on-line quantification of left ventricular dimensions and function by echocardiography with backscatter imaging and lateral gain compensation
    • Perez J.E., Klein S.C., Prater D.M., Fraser C.E., Cardona H., Waggoner A.D., Holland M.R., Miller J.G., Sobel B.E. Automated, on-line quantification of left ventricular dimensions and function by echocardiography with backscatter imaging and lateral gain compensation. Am J Cardiol. 70:(13):1992;1200-1205.
    • (1992) Am J Cardiol , vol.70 , Issue.13 , pp. 1200-1205
    • Perez, J.E.1    Klein, S.C.2    Prater, D.M.3    Fraser, C.E.4    Cardona, H.5    Waggoner, A.D.6    Holland, M.R.7    Miller, J.G.8    Sobel, B.E.9
  • 15
    • 0026521021 scopus 로고
    • Segmenting ultrasound images of the prostate using neural networks
    • Prater J.S., Richard W.D. Segmenting ultrasound images of the prostate using neural networks. Ultrason Imaging. 14:(2):1992;159-185.
    • (1992) Ultrason Imaging , vol.14 , Issue.2 , pp. 159-185
    • Prater, J.S.1    Richard, W.D.2
  • 16
    • 0027689372 scopus 로고
    • Neural network approach for computer-assisted interpretation of ultrasound images of the gallbladder
    • Rinast E., Linder R., Weiss H.D. Neural network approach for computer-assisted interpretation of ultrasound images of the gallbladder. Eur J Radiol. 17:1993;175-178.
    • (1993) Eur J Radiol , vol.17 , pp. 175-178
    • Rinast, E.1    Linder, R.2    Weiss, H.D.3
  • 17
    • 21844510105 scopus 로고
    • Efficient numerical methods in non uniform sampling theory
    • Strohmer T. Efficient numerical methods in non uniform sampling theory. Numer Math. 69:1995;423-440.
    • (1995) Numer Math , vol.69 , pp. 423-440
    • Strohmer, T.1
  • 18
    • 0029490342 scopus 로고
    • Contour detection using artificial neural network pre-segmentation
    • In: Murray A, Arzbaecher R, eds Piscataway, NJ: IEEE
    • Suessner M, Budil M, Strohmer Th., Greher M, Porenta G, Binder Th. Contour detection using artificial neural network pre-segmentation. In: Murray A, Arzbaecher R, eds. Computers in cardiology. Piscataway, NJ: IEEE, 1995:737-740.
    • (1995) Computers in Cardiology , pp. 737-740
    • Suessner, M.1    Budil, M.2    Strohmer, Th.3    Greher, M.4    Porenta, G.5    Binder, Th.6
  • 20
    • 0023859106 scopus 로고
    • Improved accuracy of echocardiographic endocardial borders by spatiotemporal filtered Fourier reconstruction: Description of the method and optimization of filter cutoffs
    • Thomas J.D., Hagege A.A., Choong C.Y., Wilkins G.T., Newell J.B., Weyman A.E. Improved accuracy of echocardiographic endocardial borders by spatiotemporal filtered Fourier reconstruction description of the method and optimization of filter cutoffs . Circulation. 77:(2):1988;415-428.
    • (1988) Circulation , vol.77 , Issue.2 , pp. 415-428
    • Thomas, J.D.1    Hagege, A.A.2    Choong, C.Y.3    Wilkins, G.T.4    Newell, J.B.5    Weyman, A.E.6
  • 21
    • 0031103367 scopus 로고    scopus 로고
    • Application of automatic boundary detection for computerized quantitative analysis of left ventricular regional wall motion by two-dimensional echocardiography
    • Tsai L.M., Chen T.P., Chen T.S., Chen J.H. Application of automatic boundary detection for computerized quantitative analysis of left ventricular regional wall motion by two-dimensional echocardiography. J Ultrasound Med. 16:(3):1997;177-182.
    • (1997) J Ultrasound Med , vol.16 , Issue.3 , pp. 177-182
    • Tsai, L.M.1    Chen, T.P.2    Chen, T.S.3    Chen, J.H.4
  • 22
    • 0026632428 scopus 로고
    • Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system
    • Vandenberg B.F., Rath L.S., Stuhlmuller P., Melton H.E. Jr, Skorton D.J. Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system. Circulation. 86:(1):1992;159-166.
    • (1992) Circulation , vol.86 , Issue.1 , pp. 159-166
    • Vandenberg, B.F.1    Rath, L.S.2    Stuhlmuller, P.3    Melton H.E., Jr.4    Skorton, D.J.5
  • 23
    • 0029399668 scopus 로고
    • The clinical utility of automatic boundary detection for the determination of left ventricular volume: A comparison with conventional off-line echocardiographic quantification
    • Wilson G.M., Rahko P.S. The clinical utility of automatic boundary detection for the determination of left ventricular volume a comparison with conventional off-line echocardiographic quantification . J Am Soc Echocardiogr. 8:(6):1995;822-829.
    • (1995) J Am Soc Echocardiogr , vol.8 , Issue.6 , pp. 822-829
    • Wilson, G.M.1    Rahko, P.S.2
  • 24
    • 0020332185 scopus 로고
    • An approach to optimal threshold selection on a sequence of two dimensional echocardiograms
    • Zhang L.F., Geiser E.A. An approach to optimal threshold selection on a sequence of two dimensional echocardiograms. IEE Trans Biomed Eng. 29:(8):1994;577-580.
    • (1994) IEE Trans Biomed Eng , vol.29 , Issue.8 , pp. 577-580
    • Zhang, L.F.1    Geiser, E.A.2
  • 25
    • 0021072354 scopus 로고
    • Validation of a computerized edge detection algorithm for quantitative two-dimensional echocardiography
    • Zwehl W., Levy R., Garcia E., Haendchen R.V., Childs W., Corday S.R., Meerbaum S., Corday E. Validation of a computerized edge detection algorithm for quantitative two-dimensional echocardiography. Circulation. 68:(5):1983;1127-1135.
    • (1983) Circulation , vol.68 , Issue.5 , pp. 1127-1135
    • Zwehl, W.1    Levy, R.2    Garcia, E.3    Haendchen, R.V.4    Childs, W.5    Corday, S.R.6    Meerbaum, S.7    Corday, E.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.