메뉴 건너뛰기




Volumn 6, Issue 4, 1998, Pages 373-377

Transcranial cerebral oximetry during carotid endarterectomy: Agreement between frontal and lateral probe measurements as compared with an electroencephalogram

Author keywords

carotid endarterectomy; lateral probe; transcranial cerebral oximetry

Indexed keywords

ANTERIOR CEREBRAL ARTERY; ARTICLE; CAROTID ARTERY OBSTRUCTION; CAROTID ENDARTERECTOMY; CONTROLLED STUDY; DOPPLER ECHOGRAPHY; ELECTROENCEPHALOGRAM; FOREHEAD; HUMAN; INTERMETHOD COMPARISON; MAJOR CLINICAL STUDY; PATIENT MONITORING; PRIORITY JOURNAL; TISSUE OXYGENATION; TRANSCUTANEOUS OXYGEN MONITORING;

EID: 0344972756     PISSN: 17085381     EISSN: None     Source Type: Journal    
DOI: 10.1177/096721099800600412     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 0026093229 scopus 로고
    • Noninvasive cerebral optical spectroscopy for monitoring oxygen delivery and hemodynamics
    • McCormick P. W., Stewart M., Goetting M. G., et al, Noninvasive cerebral optical spectroscopy for monitoring oxygen delivery and hemodynamics. Critical Care Medicine, 1991, 19, 89–97.
    • (1991) Critical Care Medicine , vol.19 , pp. 89-97
    • McCormick, P.W.1    Stewart, M.2    Goetting, M.G.3
  • 2
    • 0027936489 scopus 로고
    • Light-reflective cerebral oximetry and jugular bulb venous saturation during carotid endarterectomy
    • Williams I. M., Picton A., Farrell A., et al, Light-reflective cerebral oximetry and jugular bulb venous saturation during carotid endarterectomy. British Journal of Surgery, 1994, 81, 1291–1295.
    • (1994) British Journal of Surgery , vol.81 , pp. 1291-1295
    • Williams, I.M.1    Picton, A.2    Farrell, A.3
  • 3
    • 0025883927 scopus 로고
    • Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans
    • McCormick P. W., Stewart M., Goetting M. G., Balakrishnan G., Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans. Stroke, 1991, 22, 596–602.
    • (1991) Stroke , vol.22 , pp. 596-602
    • McCormick, P.W.1    Stewart, M.2    Goetting, M.G.3    Balakrishnan, G.4
  • 4
    • 0344367471 scopus 로고
    • Monitoring cerebral oxygen delivery and hemodynamics
    • McCormick P. W., Monitoring cerebral oxygen delivery and hemodynamics. Current Opinion in Anaesthesiology, 1991, 4, 657–661.
    • (1991) Current Opinion in Anaesthesiology , vol.4 , pp. 657-661
    • McCormick, P.W.1
  • 5
    • 0028355676 scopus 로고
    • Somanetics INVOS 3100 cerebral oximeter: Instrumentation, technique, and technology
    • Dujovny M., Slavin K. V., Cui W., et al, Somanetics INVOS 3100 cerebral oximeter: Instrumentation, technique, and technology. Neurosurgery, 1994, 34, 935–936.
    • (1994) Neurosurgery , vol.34 , pp. 935-936
    • Dujovny, M.1    Slavin, K.V.2    Cui, W.3
  • 6
    • 0028796232 scopus 로고
    • Cerebral oxygenation during pediatric surgery using deep hypothermic circulatory arrest
    • Kurth C. D., Steven J. M., Nicolson S. C., Cerebral oxygenation during pediatric surgery using deep hypothermic circulatory arrest. Anesthesiology, 1995, 82, 74–82.
    • (1995) Anesthesiology , vol.82 , pp. 74-82
    • Kurth, C.D.1    Steven, J.M.2    Nicolson, S.C.3
  • 7
    • 0027382292 scopus 로고
    • Cerebral oxygen metabolism during hypothermic circulatory arrest in humans
    • Ausman J. I., McCormick P. W., Stewart M., et al, Cerebral oxygen metabolism during hypothermic circulatory arrest in humans. Journal of Neurosurgery, 1993, 79, 810–815.
    • (1993) Journal of Neurosurgery , vol.79 , pp. 810-815
    • Ausman, J.I.1    McCormick, P.W.2    Stewart, M.3
  • 8
    • 0028024894 scopus 로고
    • Cerebral hypoxia detected by near infrared spectroscopy
    • Williams I. M., Picton A. J., Hardy S. C., et al, Cerebral hypoxia detected by near infrared spectroscopy. Anesthesia, 1994, 49, 762–766.
    • (1994) Anesthesia , vol.49 , pp. 762-766
    • Williams, I.M.1    Picton, A.J.2    Hardy, S.C.3
  • 9
    • 0028609139 scopus 로고
    • Clinical experience with transcranial cerebral oximetry
    • Slavin K. V., Dujovny M., Ausman J. I., et al, Clinical experience with transcranial cerebral oximetry. Surgical Neurology, 1994, 42, 531–540.
    • (1994) Surgical Neurology , vol.42 , pp. 531-540
    • Slavin, K.V.1    Dujovny, M.2    Ausman, J.I.3
  • 10
    • 0008118448 scopus 로고
    • Cerebral oximetry in carotid endarterectomy and acute stroke
    • ed. Greehalgh R. M., Hollier L. H. W. B. Saunders Co., London
    • Williams I.M., McCollum C., Cerebral oximetry in carotid endarterectomy and acute stroke. In Surgery for Stroke, ed. Greehalgh R. M., Hollier L. H. W. B. Saunders Co., London, 1993, pp. 129–138.
    • (1993) In Surgery for Stroke , pp. 129-138
    • Williams, I.M.1    McCollum, C.2
  • 11
    • 0029563270 scopus 로고
    • Cerebral oximetry: A useful monitor during carotid artery surgery
    • Duncan L. A., Ruckley C. V., Wildsmith A. W., Cerebral oximetry: A useful monitor during carotid artery surgery. Anaesthesia, 1995, 50, 1041–1045.
    • (1995) Anaesthesia , vol.50 , pp. 1041-1045
    • Duncan, L.A.1    Ruckley, C.V.2    Wildsmith, A.W.3
  • 13
    • 0026501378 scopus 로고
    • Intracerebral penetration of infrared light. Technical note
    • McCormick P. W., Stewart M., Lewis G., et al, Intracerebral penetration of infrared light. Technical note. Journal of Neurosurgery, 1992, 76, 315–318.
    • (1992) Journal of Neurosurgery , vol.76 , pp. 315-318
    • McCormick, P.W.1    Stewart, M.2    Lewis, G.3
  • 14
    • 84908219488 scopus 로고
    • Statistical method for assessing agreement between two methods of clinical measurement
    • Bland J. M., Altman D. G., Statistical method for assessing agreement between two methods of clinical measurement. Lancet, 1986, 1, 307–310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.