메뉴 건너뛰기




Volumn 126, Issue 5, 2003, Pages 1650-1652

Closed correction of systemic semilunar valve insufficiency in the neonate

Author keywords

[No Author keywords available]

Indexed keywords

ACIDOSIS; ANNULOPLASTY; AORTA ARCH INTERRUPTION; ARTERIAL GAS; ARTERIAL TRUNK; ARTERY CATHETERIZATION; ARTICLE; ATRESIA; BLOOD PRESSURE; BRACHIOCEPHALIC TRUNK; BRAIN PERFUSION; CARDIOPULMONARY BYPASS; CASE REPORT; ECHOCARDIOGRAPHY; EXTRACORPOREAL OXYGENATION; FEMALE; FOLLOW UP; HEART ATRIUM PRESSURE; HEART BEAT; HEART FUNCTION; HEART GRAFT; HEART PERFUSION; HEMODYNAMIC MONITORING; HUMAN; HYPOPLASTIC LEFT HEART SYNDROME; HYPOTENSION; LUNG CIRCULATION; MALE; MITRAL VALVE REGURGITATION; MITRAL VALVE STENOSIS; NEWBORN; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; TRANSESOPHAGEAL ECHOCARDIOGRAPHY;

EID: 0344924956     PISSN: 00225223     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0022-5223(03)01016-X     Document Type: Article
Times cited : (4)

References (4)
  • 1
    • 0033962449 scopus 로고    scopus 로고
    • Regional low-flow perfusion provides cerebral circulatory support during neonatal aortic arch reconstruction
    • Pigula FA, Nemoto EM, Griffith BP, Siewers RD. Regional low-flow perfusion provides cerebral circulatory support during neonatal aortic arch reconstruction. J Thorac Cardiovasc Surg. 2000;119:331-9.
    • (2000) J Thorac Cardiovasc Surg , vol.119 , pp. 331-339
    • Pigula, F.A.1    Nemoto, E.M.2    Griffith, B.P.3    Siewers, R.D.4
  • 2
    • 0035991251 scopus 로고    scopus 로고
    • Subvalvular circular annuloplasty as a component of aortic valve repair
    • Izumoto H, Kawazoe K, Kawase T, Kim H. Subvalvular circular annuloplasty as a component of aortic valve repair. J Heart Valve Dis. 2002;11:383-5.
    • (2002) J Heart Valve Dis , vol.11 , pp. 383-385
    • Izumoto, H.1    Kawazoe, K.2    Kawase, T.3    Kim, H.4
  • 3
    • 0027204289 scopus 로고
    • Present status of reconstructive surgery for aortic valve disease
    • Duran CM. Present status of reconstructive surgery for aortic valve disease. J Card Surg. 1992;8(4):443-52.
    • (1992) J Card Surg , vol.8 , Issue.4 , pp. 443-452
    • Duran, C.M.1
  • 4
    • 0035172477 scopus 로고    scopus 로고
    • Aortopulmonary size discrepancy is not a contraindication to the pediatric Ross operation
    • Pigula FA, Paolillo J, McGratin M, et al. Aortopulmonary size discrepancy is not a contraindication to the pediatric Ross operation. Ann Thorac Surg. 2001;72(5):1610-3.
    • (2001) Ann Thorac Surg , vol.72 , Issue.5 , pp. 1610-1613
    • Pigula, F.A.1    Paolillo, J.2    McGratin, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.