메뉴 건너뛰기




Volumn 96, Issue 3, 2003, Pages 615-620

New thallium(I) ion selective electrode based on indeno pyran compound

Author keywords

Ion selective electrode; Potentiometric titrations; PVC membrane sensor; Thallium(I)

Indexed keywords

ASSAYS; COMPLEXATION; FLUORESCENCE; FOURIER TRANSFORM INFRARED SPECTROSCOPY; ION SELECTIVE ELECTRODES; POLYMERIC MEMBRANES; POLYVINYL CHLORIDES; THALLIUM; TITRATION; X RAY DIFFRACTION ANALYSIS;

EID: 0344896719     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2003.07.004     Document Type: Article
Times cited : (13)

References (22)
  • 1
    • 0019307317 scopus 로고
    • Thallium intoxication: Clinicopathological aspects of four cases
    • Moeschlin S. Thallium intoxication: clinicopathological aspects of four cases. Clin. Toxicol. 17:1980;133-146.
    • (1980) Clin. Toxicol. , vol.17 , pp. 133-146
    • Moeschlin, S.1
  • 2
    • 0038585721 scopus 로고
    • Potentiometric studies with thallium(I)-heteropoly acid salt-epoxy resin membranes
    • Coetzee C.J., Basson A.J. Potentiometric studies with thallium(I)-heteropoly acid salt-epoxy resin membranes. Anal. Chim. Acta. 64:1973;300-304.
    • (1973) Anal. Chim. Acta. , vol.64 , pp. 300-304
    • Coetzee, C.J.1    Basson, A.J.2
  • 3
    • 0003977506 scopus 로고
    • A thallium(I)-selective electrode based on a liquid ion-exchanger containing O,O′-didecyldithiophosphoric acid
    • Szczepaniak W., Ren K. A thallium(I)-selective electrode based on a liquid ion-exchanger containing O,O′-didecyldithiophosphoric acid. Anal. Chim. Acta. 82:1976;37-44.
    • (1976) Anal. Chim. Acta , vol.82 , pp. 37-44
    • Szczepaniak, W.1    Ren, K.2
  • 4
    • 0013471445 scopus 로고
    • Cesium- and thallium(I)-sensitive liquid membrane electrodes based on cesium- and thalliumtetrakis(m-trifluoromethylphenyl) borates
    • Coetzee C.J., Basson A.J. Cesium- and thallium(I)-sensitive liquid membrane electrodes based on cesium- and thalliumtetrakis(m-trifluoromethylphenyl) borates. Anal. Chim. Acta. 92:1977;399-403.
    • (1977) Anal. Chim. Acta , vol.92 , pp. 399-403
    • Coetzee, C.J.1    Basson, A.J.2
  • 5
    • 0344858915 scopus 로고
    • A thallium(I)-selective electrode containing isatin oximates
    • Janson E.K., Cedere D. A thallium(I)-selective electrode containing isatin oximates. Latv. Kim. Z. 6:1992;680.
    • (1992) Latv. Kim. Z. , vol.6 , pp. 680
    • Janson, E.K.1    Cedere, D.2
  • 6
    • 0037571423 scopus 로고
    • Properties and analytical application of a thallium(I) ion-selective electrode
    • Coetzee C.J. Properties and analytical application of a thallium(I) ion-selective electrode. Talanta. 32:1985;821-823.
    • (1985) Talanta , vol.32 , pp. 821-823
    • Coetzee, C.J.1
  • 7
    • 0042795521 scopus 로고
    • Thallium-selective PVC membrane electrodes based on bis(crown ether)s
    • Tamura H., Kimura K., Shono T. Thallium-selective PVC membrane electrodes based on bis(crown ether)s. J. Electroanal. Chem. 115:1980;115-121.
    • (1980) J. Electroanal. Chem. , vol.115 , pp. 115-121
    • Tamura, H.1    Kimura, K.2    Shono, T.3
  • 8
    • 0037909507 scopus 로고
    • Polymer membrane thallium(I)-selective electrode based on dibenzo-crown-6 ethers
    • Yamashoji Y., Tanaka M., Nagamune S., Ouchi M. Polymer membrane thallium(I)-selective electrode based on dibenzo-crown-6 ethers. Anal. Sci. 7:1991;485-486.
    • (1991) Anal. Sci. , vol.7 , pp. 485-486
    • Yamashoji, Y.1    Tanaka, M.2    Nagamune, S.3    Ouchi, M.4
  • 9
    • 84996326404 scopus 로고
    • Thallium(I) ion-selective electrode based on Polythiamacrocycles
    • Yoshitaka M., Kenji Y., Yasuhiko S., Toshiyuki S. Thallium(I) ion-selective electrode based on Polythiamacrocycles. Anal. Sci. 10:1994;491-495.
    • (1994) Anal. Sci. , vol.10 , pp. 491-495
    • Yoshitaka, M.1    Kenji, Y.2    Yasuhiko, S.3    Toshiyuki, S.4
  • 10
    • 0000425551 scopus 로고    scopus 로고
    • Remarkable thallium(I) selectivity for ion sensors based on π-coordination of calix[4]arene neutral carriers
    • Kimura K., Tatsumi K., Yokoyama M., Ouchi M., Mocerino M. Remarkable thallium(I) selectivity for ion sensors based on π-coordination of calix[4]arene neutral carriers. Anal. Commun. 36:1999;229-230.
    • (1999) Anal. Commun. , vol.36 , pp. 229-230
    • Kimura, K.1    Tatsumi, K.2    Yokoyama, M.3    Ouchi, M.4    Mocerino, M.5
  • 11
    • 0032485694 scopus 로고    scopus 로고
    • A novel PVC membrane sensor for potentiometric determination of thallium(I)
    • Saleh M.B. A novel PVC membrane sensor for potentiometric determination of thallium(I). J. Electroanal. Chem. 448:1998;33-39.
    • (1998) J. Electroanal. Chem. , vol.448 , pp. 33-39
    • Saleh, M.B.1
  • 12
    • 0032962774 scopus 로고    scopus 로고
    • Reaction of 2-(3-methyl-5-oxo-1-phenyl-1H-pyrazol-4(5H)-ylidene) propandinitrile with 1,3-dicarbonyl compounds
    • Mohsen Gomaa A.M. Reaction of 2-(3-methyl-5-oxo-1-phenyl-1H-pyrazol-4(5H)-ylidene) propandinitrile with 1,3-dicarbonyl compounds. Pharmazie. 54:1999;352-354.
    • (1999) Pharmazie , vol.54 , pp. 352-354
    • Mohsen Gomaa, A.M.1
  • 13
    • 37049131032 scopus 로고
    • Calcium-sensitive electrode based on a liquid ion exchanger in a poly(vinyl chloride) matrix
    • Moody G.J., Oke R.B., Thomas J.D.R. Calcium-sensitive electrode based on a liquid ion exchanger in a poly(vinyl chloride) matrix. Analyst. 95:1970;910-918.
    • (1970) Analyst , vol.95 , pp. 910-918
    • Moody, G.J.1    Oke, R.B.2    Thomas, J.D.R.3
  • 14
    • 33847804944 scopus 로고
    • PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments
    • Craggs A., Moody G.J., Thomas J.D.R. PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments. J. Chem. Educ. 51:1974;541-544.
    • (1974) J. Chem. Educ. , vol.51 , pp. 541-544
    • Craggs, A.1    Moody, G.J.2    Thomas, J.D.R.3
  • 15
    • 0021393907 scopus 로고
    • Liquid and poly(vinyl chloride) atropine-reineckate membrane electrodes for determination of atropine
    • Hassan S.S.M., Tadros F.S. Liquid and poly(vinyl chloride) atropine-reineckate membrane electrodes for determination of atropine. Anal. Chem. 65:1984;542-546.
    • (1984) Anal. Chem. , vol.65 , pp. 542-546
    • Hassan, S.S.M.1    Tadros, F.S.2
  • 16
    • 20644436463 scopus 로고    scopus 로고
    • Novel zinc ion-selective electrode based on sulipride drug
    • Saleh M.B., Abdel Gaber A.A. Novel zinc ion-selective electrode based on sulipride drug. Electroanalysis. 13:2001;104-108.
    • (2001) Electroanalysis , vol.13 , pp. 104-108
    • Saleh, M.B.1    Abdel Gaber, A.A.2
  • 17
    • 0037413516 scopus 로고    scopus 로고
    • DDB liver drug as a novel ionophore for potentiometric barium(II) membrane sensor
    • Hassan S.S.M., Saleh M.B., Abdel Gaber A.A., Abdel Kream N.A. DDB liver drug as a novel ionophore for potentiometric barium(II) membrane sensor. Talanta. 59:2003;161-166.
    • (2003) Talanta , vol.59 , pp. 161-166
    • Hassan, S.S.M.1    Saleh, M.B.2    Abdel Gaber, A.A.3    Abdel Kream, N.A.4
  • 20
    • 0000992527 scopus 로고
    • Anomalies experienced in work with ion-selective electrodes and interpretation thereof
    • Punger E., Toth K. Anomalies experienced in work with ion-selective electrodes and interpretation thereof. Anal. Proc. 22:1985;352-353.
    • (1985) Anal. Proc. , vol.22 , pp. 352-353
    • Punger, E.1    Toth, K.2
  • 22
    • 84953464479 scopus 로고
    • Reduction of the anion interference in neutral carrier liquid-membrane electrodes responsive to cations
    • Morf W.E., Kahr G., Simon W. Reduction of the anion interference in neutral carrier liquid-membrane electrodes responsive to cations. Anal. Lett. 7:1974;9-22.
    • (1974) Anal. Lett. , vol.7 , pp. 9-22
    • Morf, W.E.1    Kahr, G.2    Simon, W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.