-
1
-
-
0023890926
-
Metallic wear in failed titanium-alloy total hip replacements: A histological and quantitative analysis
-
Agins HJ, Alcock NW, Bansal M, Salvati EA, Wilson PD Jr, Pellicci PM, Bullough PG (1988) Metallic wear in failed titanium-alloy total hip replacements: a histological and quantitative analysis. J Bone Joint Surg [Am] 70:347-356
-
(1988)
J Bone Joint Surg [Am]
, vol.70
, pp. 347-356
-
-
Agins, H.J.1
Alcock, N.W.2
Bansal, M.3
Salvati, E.A.4
Wilson P.D., Jr.5
Pellicci, P.M.6
Bullough, P.G.7
-
2
-
-
0021627548
-
Metal/Cement interface strength in cemented stem fixation
-
Ahmed AM, Raab S, Miller JE (1984) Metal/Cement interface strength in cemented stem fixation. J Orthop Res 2: 105-117
-
(1984)
J Orthop Res
, vol.2
, pp. 105-117
-
-
Ahmed, A.M.1
Raab, S.2
Miller, J.E.3
-
3
-
-
0029941585
-
Porosity reduction in bone cement at the cement-stem interface
-
Bishop NE, Ferguson S, Tepic S (1996) Porosity reduction in bone cement at the cement-stem interface. J Bone Joint Surg [Br] 78:349-356
-
(1996)
J Bone Joint Surg [Br]
, vol.78
, pp. 349-356
-
-
Bishop, N.E.1
Ferguson, S.2
Tepic, S.3
-
4
-
-
0028118416
-
Tensile bonding strength of the cement prosthesis interface
-
Davies JP, Harris WH (1994) Tensile bonding strength of the cement prosthesis interface. Orthopedics 17: 171-173
-
(1994)
Orthopedics
, vol.17
, pp. 171-173
-
-
Davies, J.P.1
Harris, W.H.2
-
6
-
-
0344123342
-
-
Exeter das Total-Hüftsystem. Off print (Prospects), Howmedica, Germany
-
Howmedica International (1993) Bewährte Technik für ein sicheres Leben. Exeter das Total-Hüftsystem. Off print (Prospects), Howmedica, Germany
-
(1993)
Bewährte Technik für ein Sicheres Leben
-
-
-
8
-
-
0025784682
-
The initiation of failure in cemented femoral components of hip arthroplasties
-
Jasty M, Maloney WJ, Bragdon CR, O'Connor DO, Haire T, Harris WH (1991) The initiation of failure in cemented femoral components of hip arthroplasties. J Bone Joint Surg [Br] 73: 551-558
-
(1991)
J Bone Joint Surg [Br]
, vol.73
, pp. 551-558
-
-
Jasty, M.1
Maloney, W.J.2
Bragdon, C.R.3
O'Connor, D.O.4
Haire, T.5
Harris, W.H.6
-
9
-
-
0023084698
-
The effect of mixing technique and surgical technique on the properties of bone cement
-
Willert HG, Buchhom G (eds). Knochenzement. Huber Verlag, Bern
-
Lee AJ (1987) The effect of mixing technique and surgical technique on the properties of bone cement. In: Willert HG, Buchhom G (eds) Aktuelle Probleme in Chirurgie und Orthopädie 31. Knochenzement. Huber Verlag, Bern
-
(1987)
Aktuelle Probleme in Chirurgie und Orthopädie 31
-
-
Lee, A.J.1
-
12
-
-
0022062279
-
The load carrying and fatigue properties of the stem-cement interface with smooth and porous coated femoral components
-
Manley MT, Stern LS (1985) The load carrying and fatigue properties of the stem-cement interface with smooth and porous coated femoral components. J Biomed Mater Res 19: 563-575
-
(1985)
J Biomed Mater Res
, vol.19
, pp. 563-575
-
-
Manley, M.T.1
Stern, L.S.2
-
13
-
-
0344985957
-
Results of primary total hip reconstruction with cemented titanium total hip arthroplasty. Minimum four year results
-
New Orleans, February 8-13
-
Martell JM, Pierson RH, Sheinkop MB, Galante JO (1990) Results of primary total hip reconstruction with cemented titanium total hip arthroplasty. Minimum four year results. Presented at 57th annual meeting of the American Academy of Orthopaedic Surgeons, New Orleans, February 8-13
-
(1990)
57th Annual Meeting of the American Academy of Orthopaedic Surgeons
-
-
Martell, J.M.1
Pierson, R.H.2
Sheinkop, M.B.3
Galante, J.O.4
-
14
-
-
0029112497
-
Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement
-
Mohler CG, Callaghan JJ, Collis DK, Johnston RS (1995) Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement. J Bone Joint Surg [Am] 77: 1315-1322
-
(1995)
J Bone Joint Surg [Am]
, vol.77
, pp. 1315-1322
-
-
Mohler, C.G.1
Callaghan, J.J.2
Collis, D.K.3
Johnston, R.S.4
-
15
-
-
1642532353
-
The mechanism of loosening in cemented hip prostheses determined from long-term results
-
Müller RT, Heger I, Oldenburg M (1997) The mechanism of loosening in cemented hip prostheses determined from long-term results. Arch Orthop Trauma Surg 116:41-45
-
(1997)
Arch Orthop Trauma Surg
, vol.116
, pp. 41-45
-
-
Müller, R.T.1
Heger, I.2
Oldenburg, M.3
-
17
-
-
0027296132
-
Particulate metallic debris in cemented total hip arthroplasty
-
Salvati EA, Betts F, Doty SB (1993) Particulate metallic debris in cemented total hip arthroplasty. Clin Orthop 293: 160-173
-
(1993)
Clin Orthop
, vol.293
, pp. 160-173
-
-
Salvati, E.A.1
Betts, F.2
Doty, S.B.3
-
18
-
-
0024512028
-
Some factors affecting the strength of the cement-metal interface
-
Stone MH, Wilkinson R, Stother IG (1989) Some factors affecting the strength of the cement-metal interface. J Bone Joint Surg [Br] 71:217-221
-
(1989)
J Bone Joint Surg [Br]
, vol.71
, pp. 217-221
-
-
Stone, M.H.1
Wilkinson, R.2
Stother, I.G.3
-
20
-
-
0030453223
-
Crevice corrosion of cemented titanium alloy stems in total hip replacements
-
Willert HG, Brobäck LG, Buchhorn GH, Ing D, Jensen PH, Köster G, Lang I, Ochsner P, Schenk R (1996) Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop 333:51-75
-
(1996)
Clin Orthop
, vol.333
, pp. 51-75
-
-
Willert, H.G.1
Brobäck, L.G.2
Buchhorn, G.H.3
Ing, D.4
Jensen, P.H.5
Köster, G.6
Lang, I.7
Ochsner, P.8
Schenk, R.9
|