메뉴 건너뛰기




Volumn 27, Issue SUPPL. 1, 1999, Pages

Reduced rates of catheter-associated infection by use of a new silver-impregnated central venous catheter

Author keywords

[No Author keywords available]

Indexed keywords

SILVER;

EID: 0344780199     PISSN: 03008126     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02561621     Document Type: Article
Times cited : (72)

References (45)
  • 1
    • 0019547030 scopus 로고
    • Nosocomial bacteremia. An epidemiologic overview
    • Maki, D. G.: Nosocomial bacteremia. An epidemiologic overview. Am. J. Med. 70 (1981) 183-196.
    • (1981) Am. J. Med. , vol.70 , pp. 183-196
    • Maki, D.G.1
  • 2
    • 0002521284 scopus 로고
    • Pathogenesis, prevention, and management of infections due to intravascular devices used for infusion therapy
    • Bisno, A. L., Waldvogel, F. A. (eds); American Society for Microbiology, Washington D. C.
    • Maki, D. G.: Pathogenesis, prevention, and management of infections due to intravascular devices used for infusion therapy. In: Bisno, A. L., Waldvogel, F. A. (eds); Infections associated with indwelling medical devices. American Society for Microbiology, Washington D. C., 1994, pp. 161-177.
    • (1994) Infections Associated with Indwelling Medical Devices , pp. 161-177
    • Maki, D.G.1
  • 3
    • 0002927802 scopus 로고
    • IV-related infections
    • Wenzel, R. P. (ed.): Williams & Wilkins, Baltimore
    • Widmer, A. F.: IV-related infections. In: Wenzel, R. P. (ed.): Nosocomial infections. Williams & Wilkins, Baltimore, 1993. pp. 556-579.
    • (1993) Nosocomial Infections , pp. 556-579
    • Widmer, A.F.1
  • 4
    • 0002581885 scopus 로고
    • Nosocomial bloodstream infections
    • Wenzel, R. P. (eds): Williams & Wilkins, Baltimore
    • Pittet, D.: Nosocomial bloodstream infections. In: Wenzel, R. P. (eds): Nosocomial infections, Williams & Wilkins, Baltimore 1993, pp. 512-555.
    • (1993) Nosocomial Infections , pp. 512-555
    • Pittet, D.1
  • 5
    • 0033058068 scopus 로고    scopus 로고
    • Catheter-associated primary bloodstream infections: Epidemiology and preventive methods
    • Gastmeier, P., Weist, K., Rüden, H.: Catheter-associated primary bloodstream infections: epidemiology and preventive methods. Infection 27 (Suppl. 1) (1999) S 1-6.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 1-6
    • Gastmeier, P.1    Weist, K.2    Rüden, H.3
  • 6
    • 0007797795 scopus 로고
    • Nosocomial bloodsteam infections in critically ill patients. Excess length stay, extra costs, and attributable mortality
    • Pittet, D., Tarara, D., Wenzel, R. P.: Nosocomial bloodsteam infections in critically ill patients. Excess length stay, extra costs, and attributable mortality, JAMA 272 (1994) 1819-1820.
    • (1994) JAMA , vol.272 , pp. 1819-1820
    • Pittet, D.1    Tarara, D.2    Wenzel, R.P.3
  • 7
    • 0023002793 scopus 로고
    • Total parenteral nutrition catheter sepsis: Impact of the team approach
    • Faubion, W. C., Wesley, J. R., Khalidi, N., Silva, J.: Total parenteral nutrition catheter sepsis: impact of the team approach. J. Parenter. Enteral Nutr. 10 (1986) 642-645.
    • (1986) J. Parenter. Enteral Nutr. , vol.10 , pp. 642-645
    • Faubion, W.C.1    Wesley, J.R.2    Khalidi, N.3    Silva, J.4
  • 9
    • 0023941431 scopus 로고
    • Beurteilung verschiedener verbandstechniken zur verhütung von infektionen durch zentrale venenkatheter: Fixomull-klebevlies, tegaderm-folienverband, nobecutan-sprühfilm
    • Frank, U., Eisenbeis, S., Daschner, F.: Beurteilung verschiedener Verbandstechniken zur Verhütung von Infektionen durch zentrale Venenkatheter: Fixomull-Klebevlies, Tegaderm-Folienverband, Nobecutan-Sprühfilm. Intensivmed. 25 (1988) 187-191.
    • (1988) Intensivmed. , vol.25 , pp. 187-191
    • Frank, U.1    Eisenbeis, S.2    Daschner, F.3
  • 10
    • 0026772839 scopus 로고
    • Comparison of the in vitro activities of the topical antimicrobials azelaic acid, nitrofurazone, silver sulphadiazine and mupirocin against methicillin-resistant Staphylococcus aureus
    • Maple, P. A. C., Hamilton-Miller, J. M. T., Brumfitt, W.: Comparison of the in vitro activities of the topical antimicrobials azelaic acid, nitrofurazone, silver sulphadiazine and mupirocin against methicillin-resistant Staphylococcus aureus. J. Antimicrob. Chemother. 29 (1992) 661-668.
    • (1992) J. Antimicrob. Chemother. , vol.29 , pp. 661-668
    • Maple, P.A.C.1    Hamilton-Miller, J.M.T.2    Brumfitt, W.3
  • 11
    • 0014608792 scopus 로고
    • Application of antibiotic ointment to the site of venous catheterization - A controlled trial
    • Norden, C. W.: Application of antibiotic ointment to the site of venous catheterization - a controlled trial. J. Infect. Dis. 120 (1969) 611-615.
    • (1969) J. Infect. Dis. , vol.120 , pp. 611-615
    • Norden, C.W.1
  • 12
    • 0024395162 scopus 로고
    • Use of topical antiseptic in prophylaxis of catheter-related septic complications
    • Illner, H., Hsia, W. C., Rikert, S. L., Tran, R. M., Straus, D.: Use of topical antiseptic in prophylaxis of catheter-related septic complications. Surg. Gynecol. Obstet 168 (1989) 481-490.
    • (1989) Surg. Gynecol. Obstet , vol.168 , pp. 481-490
    • Illner, H.1    Hsia, W.C.2    Rikert, S.L.3    Tran, R.M.4    Straus, D.5
  • 13
    • 0025003394 scopus 로고
    • Prevention of bacteremia attributed to luminal colonization of tunneled central venous catheters with vancomycin susceptible organisms
    • Schwartz, C., Henrickson, K., Roghman, K., Powell, K.: Prevention of bacteremia attributed to luminal colonization of tunneled central venous catheters with vancomycin susceptible organisms. J. Clin. Oncol. 8 (1991) 1591-1597.
    • (1991) J. Clin. Oncol. , vol.8 , pp. 1591-1597
    • Schwartz, C.1    Henrickson, K.2    Roghman, K.3    Powell, K.4
  • 15
    • 0012343855 scopus 로고    scopus 로고
    • Kathetermaterialien: Schwierige suche nach neuen werkstoffen
    • Schierholz, J. M., Pulverer, G., Rump, A. F. E.: Kathetermaterialien: Schwierige Suche nach neuen Werkstoffen. Dtsch. Ärzteblatt 95 (1998) 813-815.
    • (1998) Dtsch. Ärzteblatt , vol.95 , pp. 813-815
    • Schierholz, J.M.1    Pulverer, G.2    Rump, A.F.E.3
  • 17
    • 0032985968 scopus 로고    scopus 로고
    • Prevention of infections caused by central venus catheter -established and novel measures
    • Bach, A.: Prevention of infections caused by central venus catheter -established and novel measures. Infection 27 Suppl. 1 (1999) S 11-15.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 11-15
    • Bach, A.1
  • 18
    • 0345379312 scopus 로고    scopus 로고
    • A new tech-nology of microdispersed silver in polyurethane induces antimicrobial activity in central venous catheters
    • Guggenbichler, J.-P., Böswald, M.: Luganer, S., Krall, T.: A new tech-nology of microdispersed silver in polyurethane induces antimicrobial activity in central venous catheters. Infection 27 (Suppl. 1) (1999) S 16-23.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 16-23
    • Guggenbichler, J.-P.1    Böswald, M.2    Luganer, S.3    Krall, T.4
  • 19
    • 0025828679 scopus 로고
    • Reduced intravascular catheter infection by antibiotic bonding. A prospective, randomized, controlled trial
    • Kamal, G. D., Pfaller, M. A., Rempe, L. E., Jebson, P. J.: Reduced intravascular catheter infection by antibiotic bonding. A prospective, randomized, controlled trial. JAMA 265 (1991) 2364-2368.
    • (1991) JAMA , vol.265 , pp. 2364-2368
    • Kamal, G.D.1    Pfaller, M.A.2    Rempe, L.E.3    Jebson, P.J.4
  • 20
    • 0030033266 scopus 로고    scopus 로고
    • The broad-spectrum activity and efficacy of catheters coated with minocyclinc and rifampin
    • Raad, I., Darouche, R., Hachem, R., Mansouri, M., Bodey, G. P.: The broad-spectrum activity and efficacy of catheters coated with minocyclinc and rifampin. J. Infec. Dis. 173 (1996) 418-124.
    • (1996) J. Infec. Dis. , vol.173 , pp. 418-1124
    • Raad, I.1    Darouche, R.2    Hachem, R.3    Mansouri, M.4    Bodey, G.P.5
  • 21
    • 0029433887 scopus 로고
    • Antimicrobial activity and biocompatibility of polyurethane and silicone catheters containing low concentrations of silver: A new perspective in prevention of polymer-associated foreign-body infections
    • Böswald, M., Girisch, M., Greil, J., Spies, T., Stehr, K., Krall, T., Guggenbichler, J.-P.: Antimicrobial activity and biocompatibility of polyurethane and silicone catheters containing low concentrations of silver: a new perspective in prevention of polymer-associated foreign-body infections. Zbl. Bakt. 283 (1995) 187-200.
    • (1995) Zbl. Bakt. , vol.283 , pp. 187-200
    • Böswald, M.1    Girisch, M.2    Greil, J.3    Spies, T.4    Stehr, K.5    Krall, T.6    Guggenbichler, J.-P.7
  • 22
    • 0345034572 scopus 로고    scopus 로고
    • The Erlanger silver catheter: In vitro results for antimicrobial activity
    • Bechert, T., Böswald, M., Lugauer, S., Regenfus, A., Greil, J., Guggenbichler, J.-P.: The Erlanger silver catheter: in vitro results for antimicrobial activity. Infection 27 (Suppl. 1) (1998) S 24-29.
    • (1998) Infection , vol.27 , Issue.SUPPL. 1 , pp. 24-29
    • Bechert, T.1    Böswald, M.2    Lugauer, S.3    Regenfus, A.4    Greil, J.5    Guggenbichler, J.-P.6
  • 23
    • 0344517081 scopus 로고    scopus 로고
    • Determination of the silver ion release from polyurethanes enriched with silver
    • Joyce-Wöhrmann, R. M., Münstedt, H.: Determination of the silver ion release from polyurethanes enriched with silver. Infection 27 (Suppl. 1) (1999) S 46-18.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 46-118
    • Joyce-Wöhrmann, R.M.1    Münstedt, H.2
  • 24
    • 18244429078 scopus 로고    scopus 로고
    • Thermoplastic polyurethane the material used for the Erlanger silver catheter
    • Hentschel, T., Münsted, H.: Thermoplastic polyurethane the material used for the Erlanger silver catheter. Infection 27 (Suppl. 1) (1999) S 43-45.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 43-45
    • Hentschel, T.1    Münsted, H.2
  • 28
    • 0033027437 scopus 로고    scopus 로고
    • Clinical study of the Erlanger silver catheter - Data management and biometry
    • Martus, P., Geis, C., Lugauer, S., Böswald, M., Guggenbichler, J.-P.: Clinical study of the Erlanger silver catheter - data management and biometry. Infection 27 (Suppl. 1) (1999) S 61-68.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 61-68
    • Martus, P.1    Geis, C.2    Lugauer, S.3    Böswald, M.4    Guggenbichler, J.-P.5
  • 29
    • 0029442660 scopus 로고
    • Treatment of peritoneal-dialysis associated peritonitis with continuous versus intermittent vancomycin/teicoplanin and ceftazidime in children: Preliminary results of a prospective randomized trial
    • Klaus, G., Schaefer, F., Müller-Wiefel, D. E., Mehls, O.: Treatment of peritoneal-dialysis associated peritonitis with continuous versus intermittent vancomycin/teicoplanin and ceftazidime in children: preliminary results of a prospective randomized trial. Adv. Perit. Dial. 11 (1995) 296-301.
    • (1995) Adv. Perit. Dial. , vol.11 , pp. 296-301
    • Klaus, G.1    Schaefer, F.2    Müller-Wiefel, D.E.3    Mehls, O.4
  • 30
    • 0017734445 scopus 로고
    • A semiquantitative culture method for identifying intravenous catheter-related infection
    • Maki, D. G., Weise, C. F., Sarafin, H. W.: A semiquantitative culture method for identifying intravenous catheter-related infection. N. Engl. J. Med. 296 (1977) 1305-1309,
    • (1977) N. Engl. J. Med. , vol.296 , pp. 1305-1309
    • Maki, D.G.1    Weise, C.F.2    Sarafin, H.W.3
  • 31
    • 0033034485 scopus 로고    scopus 로고
    • Silver catheter study: Methods and results of microbiological investigations
    • Schoerner, C., Lugauer, S., Regenfus, A.: Silver catheter study: methods and results of microbiological investigations. Infection 27 (Suppl. 1) (1999) S 54-55.
    • (1999) Infection , vol.27 , Issue.SUPPL. 1 , pp. 54-55
    • Schoerner, C.1    Lugauer, S.2    Regenfus, A.3
  • 32
    • 0001053883 scopus 로고
    • Draft guidelines for prevention of intravascular device-related infections; Part 1: Intravascular device-related infections: An overview; Part 2: Recommendations for prevention of intravascular device-related infections: Notice of comment period
    • Centers for Disease Control and Prevention: Draft guidelines for prevention of intravascular device-related infections; Part 1: Intravascular device-related infections: an overview; Part 2: Recommendations for prevention of intravascular device-related infections: notice of comment period. Federal Register 60 (1995) 49978-50006.
    • (1995) Federal Register , vol.60 , pp. 49978-50006
  • 33
    • 0000687647 scopus 로고    scopus 로고
    • The hospital infection control practices advisory committee. Guideline for prevention of intravascular device-related infections
    • Pearson, M. L.: The hospital infection control practices advisory committee. Guideline for prevention of intravascular device-related infections. Am. J. Infect. Control 24 (1996) 262-293.
    • (1996) Am. J. Infect. Control , vol.24 , pp. 262-293
    • Pearson, M.L.1
  • 35
    • 0030791566 scopus 로고    scopus 로고
    • Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter
    • Maki, D. G., Stolz, S. M., Wheeler, S. J., Mermel, L. A.: Prevention of central venous catheter-related bloodstream infection by use of an antiseptic-impregnated catheter. Ann. Intern. Med. 127 (1997) 257-266.
    • (1997) Ann. Intern. Med. , vol.127 , pp. 257-266
    • Maki, D.G.1    Stolz, S.M.2    Wheeler, S.J.3    Mermel, L.A.4
  • 36
    • 0028216476 scopus 로고
    • Prevention of bacterial colonization of intravenous catheters by antiseptic impregnation of polyurethane polymers
    • Bach, A., Böhrer, H., Motsch, J., Martin, E., Geiss, H. K., Sonntag, H. G.: Prevention of bacterial colonization of intravenous catheters by antiseptic impregnation of polyurethane polymers. J. Antimicrob. Chemother. 33 (1994) 969-978.
    • (1994) J. Antimicrob. Chemother. , vol.33 , pp. 969-978
    • Bach, A.1    Böhrer, H.2    Motsch, J.3    Martin, E.4    Geiss, H.K.5    Sonntag, H.G.6
  • 38
    • 0030054516 scopus 로고    scopus 로고
    • Failure of antiseptic bonding to prevent central venous catheter-related infection and sepsis
    • Ciresi, D. L., Albrecht, R. M., Volkers, P. A., Scholten, D. J.: Failure of antiseptic bonding to prevent central venous catheter-related infection and sepsis. Am. Surg. 62 (1996) 641-646.
    • (1996) Am. Surg. , vol.62 , pp. 641-646
    • Ciresi, D.L.1    Albrecht, R.M.2    Volkers, P.A.3    Scholten, D.J.4
  • 39
    • 0030000790 scopus 로고    scopus 로고
    • Decreasing catheterrelated infection and hospital costs by continuous quality improvement
    • Civetta, J. M., Hudson-Civetta, J., Ball, S.: Decreasing catheterrelated infection and hospital costs by continuous quality improvement. Crit. Care Med. 24 (1996) 1660-1665.
    • (1996) Crit. Care Med. , vol.24 , pp. 1660-1665
    • Civetta, J.M.1    Hudson-Civetta, J.2    Ball, S.3
  • 40
    • 0029036019 scopus 로고
    • Decreased bacterial adherence and biofilm formation on chlorhexidine and silver sulfadiazine-impregnated central venous catheters implanted in swine
    • Greenfield, J. I., Sampath, L., Popilskis, S. J., Brunnert, S. R., Stylianos, S., Modak, S.: Decreased bacterial adherence and biofilm formation on chlorhexidine and silver sulfadiazine-impregnated central venous catheters implanted in swine. Crit. Care Med. 23 (1995) 894-900.
    • (1995) Crit. Care Med. , vol.23 , pp. 894-900
    • Greenfield, J.I.1    Sampath, L.2    Popilskis, S.J.3    Brunnert, S.R.4    Stylianos, S.5    Modak, S.6
  • 41
    • 0029776039 scopus 로고    scopus 로고
    • No difference in catheter sepsis between standard and antiseptic central venous catheters
    • Pemberton, L. B., Ross, V., Cuddy, P., Kremer, H., Fessler, T., McGurk, E.: No difference in catheter sepsis between standard and antiseptic central venous catheters. Arch. Surg. 131 (1996) 986-989.
    • (1996) Arch. Surg. , vol.131 , pp. 986-989
    • Pemberton, L.B.1    Ross, V.2    Cuddy, P.3    Kremer, H.4    Fessler, T.5    McGurk, E.6
  • 42
    • 0002299394 scopus 로고
    • Incidence of catheter colonisation and catheter related infection with an antiseptic impregnated triple lumen catheter
    • Ramsay, J., Nolte, F., Schwarzmann, S.: Incidence of catheter colonisation and catheter related infection with an antiseptic impregnated triple lumen catheter (abstr.). Crit. Care Med. 22 (1993) A115.
    • (1993) Crit. Care Med. , vol.22
    • Ramsay, J.1    Nolte, F.2    Schwarzmann, S.3
  • 44
    • 0029869597 scopus 로고    scopus 로고
    • High incidence of line-related infection and mechanical failure of an antiseptic impregnated central venous catheter in highly immunocompromised patients
    • Ellis, M. F., Rhydderch, D., Zwaan, F., Guy, M. L., Baillie, F.: High incidence of line-related infection and mechanical failure of an antiseptic impregnated central venous catheter in highly immunocompromised patients. Scand. J. Infect. Dis. 28 (1996) 91-93.
    • (1996) Scand. J. Infect. Dis. , vol.28 , pp. 91-93
    • Ellis, M.F.1    Rhydderch, D.2    Zwaan, F.3    Guy, M.L.4    Baillie, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.